MIP SERIES
DESCRIPTION
The MIP Series offers a heavy duty,
media-isolated pressure transducer in a
compact, stainless steel construction for
use with a wide range of media including
aggressive fluids and water. The MIP
Series provides a cost-competitive
solution for wide-ranging potential
applications in tough environments.
32354483
Issue C
Heavy Duty, Media-Isolated Pressure Transducers
1 bar to 60 bar | 15 psi to 870 psi
DIFFERENTIATION
• Diagnostics: Beneficial in applications
where the sensor functionality and
the need to know internal or external
failure modes is critical.
• Great customer value: Multiple
configuration possibilities provide
flexibility of use in the application with
no up front NRE or tooling charges.
• Durable: Provides the tough
environmental capabilities needed,
including long-term stability, insulation
resistance and dielectric strength,
external freeze-thaw resistance for
the Metri-Pack 150 versions and EMC
performance.
VALUE TO CUSTOMERS
• Total Error Band (TEB) ±0.75 %FSS
(Full Scale Span) from -40°C to 125°C
for ratiometric output: Provides true
measurement performance over the
compensated temperature range;
small error promotes system uptime
and efficiency (see Figure 5).
• 4 mA to 20 mA output: Supports
transmission of output signals over
longer distances
• EMC performance: Operates reliably
in the presence of electromagnetic
fields, such as wireless signals, RF
communication, and electrical devices.
• Hermetically welded design: Supports
almost any media without the use of an
internal seal. The sensors are designed to
be used in harsh environments which see
aggressive media.
TABLE 1. POTENTIAL APPLICATIONS
INDUSTRY
Industrial:
pumps
compressors
process
HVAC/R
Transportation
Medical
FEATURES
•
•
•
•
•
Rugged, stainless steel construction
Ratiometric output: 0.5 Vdc to 4.5 Vdc
Current output: 4 mA to 20 mA
Operating temperature: -40°C to
125°C
Total Error Band: ±0.75 %FSS to
±1.0 %FSS (-40°C to 125°C) for
voltage output
Industry-leading accuracy:
±0.15 %FSS BFSL for voltage output
Long term stability: ±0.25 %FSS
Radiated immunity: 100 V/m
Drinking water approval:
NSF/ANSI/CAN 61
CE, UKCA, RoHS, REACH compliant
Mis-wiring protection
•
Certified to
NSF/ANSI/CAN 61
•
•
•
•
•
MEDIA
water, hydraulic fluids
compressed air
food, beverage, oil, gas, steam
refrigerants (butane, propane, ammonia, CO
2
, R134A, R407C,
R410A, R448A/Solstice
®
N40, R32 and R1234ze, R1234yf,
glycol + water
gasoline, diesel fuel, engine oil, brake fluid, coolants, CNG
O
2
, N
2
, CO
2
, N
2
O, air
PORTFOLIO
Honeywell offers a variety
of heavy duty pressure
transducers for potential use in
industrial and transportation
applications. To view the entire
product portfolio, click here.
MIP SERIES HEAVY DUTY, MEDIA-ISOLATED PRESSURE TRANSDUCERS
TABLE 2. ELECTRICAL SPECIFICATIONS (AT 25°C [77°F] AND UNDER UNLESS OTHERWISE NOTED.)
CHARACTERISTIC
Supply voltage (V
s
)
Output transfer function
Output load (pull up or pull down)
Short circuit protection
Current consumption
Over/reverse voltage
1
RATIOMETRIC OUTPUT (AA)
5.0 Vdc ±0.25 Vdc
10 % to 90 % of V
s
> 2 kΩ
yes
6.5 mA ±1 mA
±40 Vdc
CURRENT OUTPUT (CH)
8 Vdc to 30 Vdc
1
4 mA to 20 mA
(V
s
- 8) x 50Ω
2
_
±35 Vdc
Supply voltage:
Must be de-rated to 8 Vdc to 25 Vdc for above 100°C to 125°C [212°F to 257°F].
2
Applies at 25°C [77°F]. See Figure 4 for Current Output Supply Voltage.
TABLE 3. PERFORMANCE SPECIFICATIONS (AT 25°C [77°F] AND UNDER UNLESS OTHERWISE NOTED.)
CHARACTERISTIC
Total Error Band
1
Operating temperature range
Accuracy BFSL
3
Long term stability (1000 hr, 25°C)
Typical output resolution
Typical response time
4
Startup time
5
EMC rating (CE Conformity):
surge immunity (all leads)
electrostatic discharge
radiated immunity
fast transient burst
immunity to conducted disturbances
radiated emissions
RATIOMETRIC OUTPUT
CURRENT OUTPUT
>10 bar or >150 psi: ±0.75 %FSS (-40°C to 125°C)
±1.0 %FSS (-20°C to 85°C)
2
<10 bar or <150 psi: ±1.0 %FSS (-40°C to 125°C)
±2.0 %FSS (-40°C to 125°C)
-40°C to 125°C [-40°F to 257°F]
±0.15 %FSS
±0.25 %FSS
±0.25 %FSS
0.05 % Full Scale Pressure
1 ms
2 ms
7 ms
±1 kV line to ground per IEC 61000-4-5
±4 kV contact, ±8 kV air per IEC 61000-4-2
10 V/m (80 MHz to 1000 MHz) per IEC 61000-4-3
±1 kV per IEC 61000-4-4
3 V (150 kHz to 80 MHz) per IEC 61000-4-6
40 dBµV (30 MHz to 230 MHz), 47 dBµV (230 MHz to 1000 MHz) per CISPR 11
100 V/m (300 MHz to 2.7 GHz) per ISO 11452-2
Radiated immunity
100 V/m (200 MHz to 2.5 GHz) per ISO 11452-2
100 V/m (100 kHz to 400 MHz) per ISO 11452-5
Insulation resistance
>100 MΩ at 1k Vdc (60 s)
Dielectric strength
<1 mA at 500 Vac (60 s)
<1 mA at 1000 Vac (60 s)
Life
>10 million full scale pressure cycles
1
Total Error Band:
The maximum deviation from the ideal transfer function over the entire compensated temperature and pressure range.
Includes all errors due to offset, full scale span, pressure non-linearity, pressure hysteresis, pressure non-repeatability, thermal effect on offset,
thermal effect on span, and thermal hysteresis (see Figure 5).
2
TEB:
Above 100°C [212°F] for pressure ratings less than 4 bar [58 psi], TEB is ±1.5 %FSS for ratiometric outputs and 2.0 % FSS for other outputs.
3
Accuracy:
The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure range at 25°C
[77°F]. Includes all errors due to pressure non-linearity, pressure hysteresis, and pressure non-repeatability.
4
Response time:
The time taken by the transducer to change output from 10 % to 90 % of full scale in response to a 0 % to 100 % full scale step
input pressure.
5
Startup time:
The time needed to receive valid output after power up.
TABLE 4. ENVIRONMENTAL AND MECHANICAL SPECIFICATIONS
CHARACTERISTIC
Shock
Vibration
Ingress protection:
Metri-Pack 150 versions
cable harness versions
External freeze/thaw resistance
Wetted materials:
port
diaphragm
external seal for ports
Electrical connector material
Cable material (jacket and insulation)
PARAMETER
100 G per MIL-STD-202, Method 213, Cond. C (at 25°C [77°F])
20 G sweep, 10 Hz to 2000 Hz (at 25°C [77°F])
IP65, IP67
IP65, IP67, IP69K
>6 cycles from -30°C to 50°C [-22°F to 122°F] (Metri-Pack 150 versions only)
stainless steel 304L
stainless steel 316L
nitrile (-30°C to 100°C [-22°F to 212°F]) (other materials available)
PBT 30 %GF (UL V-0)
TPE (Thermoplastic Elastomer) flame retardant-type cable is FT1 rated per CSA
AWM-I-A/B-II-A/B specification, -40°C to 125°C [-40°F to 257°F], three 24 AWG wires.
MIP Series Heavy Duty, Media-Isolated Pressure Transducers Datasheet |
sps.honeywell.com/ast
|
2
MIP SERIES HEAVY DUTY, MEDIA-ISOLATED PRESSURE TRANSDUCERS
FIGURE 1. NOMENCLATURE AND ORDER GUIDE
For example,
MIPAN1XX010BSAAX
defines an MIP Series Heavy Duty, Media Isolated Pressure Transducer,
Metri-Pack 150, standard (UL V-0) electrical connector type, 1/4-18 NPT pressure port type, 10 bar pressure
range, sealed gage pressure reference, ratiometric: 5 Vs, 10% to 90% Vs output transfer function
MIP A N1 X X 010B S AA X
1
Series
Special
MIP
Media Isolated Pressure
X
Output Transfer Function
Electrical Connector Type
A
K
E
F
G
H
Metri-Pack 150,
Standard (UL V-0)
Cable harness
2
,
0.5 m [1.3 ft] cable length
Cable harness
2
,
1.0 m [3.2 ft] cable length
Cable harness
2
,
2,0 m [6.6 ft] cable length
Cable harness for CH output transfer
function
2
, 3,0 m [9.8 ft] cable length
Cable harness for CH output transfer
function
2
, 5,0 m [16.4 ft] cable length
AA
CH
Ratiometric: 5.0 Vs, 10% to 90% Vs
Current: 4 mA to 20 mA
Pressure Reference
Pressure Range
A
S
Absolute
Sealed gage
4
500P
600P
667P
700P
750P
800P
850P
870P
bar
001B
1 bar
020B
002B
2 bar
025B
004B
4 bar
035B
006B
6 bar
040B
046B
008B
8 bar
010B
10 bar
050B
012B
12 bar
055B
016B
16 bar
060B
psi
20 bar
25 bar
35 bar
40 bar
46 bar
50 bar
55 bar
60 bar
015P
030P
050P
060P
100P
150P
200P
250P
300P
15 psi
30 psi
50 psi
60 psi
100 psi
150 psi
200 psi
250 psi
300 psi
500 psi
600 psi
667 psi
700 psi
750 psi
800 psi
850 psi
870 psi
Pressure Port Type
Special
X
X
F1
7/16-20 UNF
1/4 inch 45° Flare
Female Schrader
(SAE J512)
G1/4 A-G
3
(ISO 1179-3)
G1/4 A-L
3
(ISO 1179-2)
M12 x 1.5
3
(ISO 6149-3)
1/4-18 NPT
(ANSI/ASME B1.20.1)
1/8-27 NPT
(ANSI/ASME B1.20.1)
Contact Honeywell Sales for custom configurations.
See Table 4 for cable material specifications.
3
Other external seal materials are available for G1, G2, and M1 Pressure port types.
4
Sealed gage option only available in pressure ranges at or above 8 bar | 100 psi.
1
2
G1
G2
M1
N1
N2
CAUTION
PRODUCT DAMAGE DUE TO MISUSE
• Ensure torque specifications are determined for the specific application. Values provided are for reference only. (Mating
materials and thread sealants can result in significantly different torque values from one application to the next.)
• Use appropriate tools (such as an open-ended wrench or deep well socket) to install transducers.
• Ensure that the proper mating electrical connector with a seal is used to connect the transducer. Improper or damaged seals
can compromise ingress protection, leading to short circuits.
• Ensure that filters are used upstream of the transducers to keep media flow free of particulates. MIP Series transducers are
dead-end devices. Particulate accumulation may clog the port or damage the diaphragm.
• Ensure that the transducer is mounted in a vertical position with the process connection (pressure port) downward to avoid
particular deposits.
• Ensure that the media does not create a residue when dried. Build-up of residue inside the transducer may affect transducer
output.
• Ensure that the transducer housing is properly grounded.
• For cable harness versions, ensure that the cable bend radius is maintained at a minimum of 38 mm [1.50 in] in the end
application assembly.
Failure to comply with these instructions may result in product damage.
MIP Series Heavy Duty, Media-Isolated Pressure Transducers Datasheet |
sps.honeywell.com/ast
|
3
MIP SERIES HEAVY DUTY, MEDIA-ISOLATED PRESSURE TRANSDUCERS
TABLE 5. PRESSURE RATINGS
BAR
OPERATING
PRESSURE
1 to 3
>3 to 12
>12 to 60
1
PSI
BURST
PRESSURE
2
207
OPERATING
PRESSURE
15 to 43.5
>43.5 to 174
>174 to 870
OVER-
PRESSURE
1
87
348
1740
3000
BURST
PRESSURE
2
OVER-
PRESSURE
1
6
24
120
Overpressure:
The maximum pressure which may safely be applied to the product for it to remain in specification once pressure
is returned to the operating pressure range. Exposure to higher pressures may cause permanent damage to the product.
2
Burst Pressure:
The maximum pressure which may be applied without causing escape of pressure media. The product should not
be expected to function after exposure to the burst pressure.
FIGURE 3. ABSOLUTE VS SEALED GAGE
Example shown is for 100 psi.
5
4.5
4.875
4.5
4
3.5
FIGURE 2. RATIOMETRIC OUTPUT TRANSFER FUNCTION
The transfer function shown here is applicable to a ratiometric
output ranging between 10 % V
supply
at null pressure to
90 % V
supply
at full scale pressure.
Compensated Pressure Range
97.5
90
Output (% V
supply
)
Output (Vdc)
Output (V)
3
2.5
2
1.5
1
100 psi absolute
100 psi sealed gage
Ideal
Total
Error
Band
10
2.5
P
min.
Pressure
P
max.
0.5
0.125
0.5
0
0
14.7
20
40
60
80
100
120
114.7
140
0.8 x V
supply
x (Pressure
applied
- P
min.
) + 0.10 x V
supply
Output (V) =
P
max.
- P
min.
Pressure (psi Absolute)
FIGURE 4. CURRENT OUTPUT SUPPLY VOLTAGE VS TEMPERATURE
32
30
Supply Voltage (V)
28
26
24
22
20
18
16
100
105
110
115
120
125
Load Resistance
10 Ohm
100 Ohm
250 Ohm
Operating Temperature (ºC)
MIP Series Heavy Duty, Media-Isolated Pressure Transducers Datasheet |
sps.honeywell.com/ast
|
4
MIP SERIES HEAVY DUTY, MEDIA-ISOLATED PRESSURE TRANSDUCERS
TOTAL ERROR BAND
Total Error Band (TEB) is a single specification that includes
the major sources of sensor error. TEB should not be confused
with accuracy, which is actually a component of TEB. TEB is the
maximum error that the sensor could experience.
Many competitors do not use TEB—they simply specify the
accuracy of their device. Their accuracy specification, however,
may exclude certain parameters. On their datasheet, the errors
are listed individually. When combined, the total error (or what
Honeywell uses the TEB specification in its datasheet because it is would be TEB) could be significant.
the most comprehensive measurement of a sensor’s true accuracy.
Honeywell also provides the accuracy specification in order to
provide a common comparison with competitors’ literature that
does not use the TEB specification.
FIGURE 5. TEB COMPONENTS FOR THE MIP SERIES
Sources of Error
Offset
Full Scale Span
Pressure Non-Linearity
Pressure Hysteresis
Pressure Non-Repeatability
Thermal Effect on Offset
Thermal Effect on Span
Thermal Hysteresis
Accuracy
BFSL
Total
Error
Band
3
TABLE 6. OUTPUT DIAGNOSTIC CODE FOR RATIOMETRIC OUTPUT
FAULT CONDITION
Over pressure
Total Error Band (%FSS)
2
1
ANALOG DIAGNOSTIC RAIL
97.5 % of V
supply
(See Figure 2.)
97.5 % of V
supply
(See Figure 2.)
supply
Sensor internal failures
0
Under pressure (for sealed gage only)
Total Error
% of V
2.5
Band
(See Figure 2.)
Power or ground loss
-1
Power or ground loss
-2
-3
-40°C
[-40°F]
high (external pull-up resistor)
low (external pull-down resistor)
-20°C
[-4°F]
0°C
[32°F]
85°C
[185°F]
125°C
[257°F]
Temperature (°C [°F])
MIP Series Heavy Duty, Media-Isolated Pressure Transducers Datasheet |
sps.honeywell.com/ast
|
5