R
ASSEMBLY INSTRUCTION
etherCON
|
NE8MX6* - CAT6
A
Cable Connector
Tools:
l
l
l
HX-CAT6
A
or pliers wrench
Wire cutter
Cable pulling lubricant
1.
Insulation Diameter: > 1.10 - 1.60 mm
Wire Size:
AWG 24/1 - AWG 22/1
(solid)
AWG 24/7 - AWG 22/7
(stranded)
A
A
Slide the boot (1.) and the chuck (2.) onto the cable.
To ease the boot assembly apply some cable pulling
lubricant to the cable ends.
2.
B
1.
40 mm
B
1.
Prepare the cable as shown and strip the jacket at a
length of 40 mm.
10 mm
S / FTP
2.
A
2. A.
S / FTP
Cut off braided shield to approx 10 mm and fold the
shield backwards.
B.
U / FTP
Remove the foil of the paired wires and bend back
the drain wire for easier handling during assembly.
Drain wire to be used for grounding.
C.
SF / UTP
Cut off braided shield to approx 10 mm and fold the
shield backwards. Cut and remove the foil screen.
U / FTP
B
10 mm
C
SF / UTP
6 mm
3.
3.
Remove the pair screening (if existing) to max. 6 mm.
4.
4.
Presort, untwist and straighten the wires as shown.
Unstraightened wires could potentially harm the IDC.
C
C
Insert the wires into the designated position of the wire
management as per below wiring scheme, either T568A
or T568B
Component
side!
2
A
2
87
Component
side!
Connection
Color code
T568A
T568B
W-G
G
W-O
BL
W - BL
O
W - BR
BR
W-O
O
W-G
BL
W - BL
G
W - BR
BR
RJ 45
PIN No.
1
2
3
4
5
6
7
8
1
1
BDA 428
B
1 2 8 7
A
128
7
3 6 4 5
Page 1
etherCON CAT6
A
- ASSEMBLY INSTRUCTION
B
D
. 0.5
max
mm
D
1.
Use HX-CAT6
A
or pliers wrench to press the wire
management together.
1.
1
1
3.
E
F
A
S / FTP & SF / UTP
B
U / FTP
1
1
G
1
1
H
B
1
1
1
B
I
2
A
1
NEUTRIK
NEUTRIK
NEUTRIK
NEUTRIK
LI
USA
UK
Vertriebs GmbH
DE / NL / AT/DK
AG
USA Inc.
(
UK
)
Ltd.
T:
T:
T:
T:
+423 / 237 24 24
+1 704 / 972 3050
+44 1983 / 811 441
+49 8131 / 280 890
Draft. Nr.: BDA 428
I
Update: 28.08.2017
I
Data subject to change without prior notice.
©
2017 NEUTRIK
®
. ALL RIGHTS RESERVED. NEUTRIK
®
, etherCON
®
is a registered trademark.
R
www.neutrik.com
B
A
2
A
2
87
1
1
B
B
A
2
A
2
87
7
B
A
2
A
2
87
A
2
A
2
87
128
7
A
2
A
87
87
2
87
B
2.
Attention:
Distance between the cable jacket and the wire
management shall not exceed 15 - 17 mm.
15 -
17 m
m
1
2.
Cut all wires with a wire cutter.
Allow wires to protrude max. 0.5 mm.
Remove the assembly guidance.
1.
3.
E
Position the ground-shells over the wires as shown.
Attention:
Align the coding nibs of the ground shells to the
grooves in between the wire pairs in the wire
management.
B
A
F
A.
Put the cable-shield over the ground shell and
distribute the shield wires circumferentially.
B.
Put the drain wire over the ground shell and wrap
the drain wire circumferentially.
2
A
2
87
7
A
G
Slide the chuck over the cable-shield / drain wire and
the ground shell towards the end-position.
Attention:
Align the slots of the chuck to the ribs of the
ground shell.
B
A
H
Slide the pre assembled cable (step G) into the housing.
Attention:
Align the side of the wire management with wire
numbers 1/2, 8/7 to the side of the housing that
has the Neutrik logo and the slot.
I
Finish the installation by turning the bushing onto the
connector.
Option:
Use the handtool HTXX-14 to tighten the bushing.
Find more details of etherCON on www.neutrik.com.
F:
F:
F:
F:
+423 / 232 53 93
+1 704 / 438 9202
+44 1983 / 811 439
+49 8131 / 280 830
NEUTRIK France
NEUTRIK Tokyo Ltd.
NEUTRIK
Hong Kong
Ltd.
NEUTRIK India Pvt. Ltd.
FR
JP
HK
IND
T:
+33 1 / 4131 6750
T:
+81 3 / 3663 4733
T:
+852 / 2687 6055
T:
+91 / 982 05 43 424
F:
+33 1 / 4131 0511
F:
+81 3 / 3663 4796
F:
+852 / 2687 6052
F:
+91 / 22 26163 540
Page 2
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Neutrik
:
8MX6