SINGLE PHASE 1.0 AMP SURF
ACE MOUNT BRIDGE RECTIFIERS
VOLTAGE RANGE
50 to 1000 Volts
ABS05
THRU
ABS10
CURRENT
1.0 Ampere
ABS
FEATURES
* Ideal for printed circuit board
* Reliable low cost construction utilizing molded
plastic technique
* High surge current capability
~
+
2.75(7.0)
MAX.
.181(4.6)
.165(4.2)
* Polarity: Symbol molded on body
* Mounting position: Any
* Weight: 0.12 grams
~
.043(1.1)
.027(0.7)
.043(1.1) .008(0.2)
.027(0.7)
MAX.
.031(0.8)
.023(0.6)
.201(5.1)
.197(4.8)
.065(1.65)
MAX.
.126(3.9)
.141(4.1)
.057(1.45)
.049(1.25)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating 25 C ambient temperature uniess otherwies specified.
Single phase half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
TYPE NUMBER
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
at Ta=40 C(Note 1)
Peak Forward Surge Current, 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Maximum Forward Voltage Drop per Bridge Element at 0.4A D.C.
Maximum DC Reverse Current
Ta=25 C
at Rated DC Blocking Voltage
Ta=125 C
Typical Thermal Resistance RqJA (Note 2)
Operating Temperature Range, T
J
Storage Temperature Range, T
STG
NOTES: 1. Mounted on P.C. Board.
2. Thermal Resistance Junction to Ambient.
ABS05
50
35
50
ABS1
100
70
100
ABS2
200
140
200
ABS4
400
280
400
1.0
30
1.0
5.0
ABS6
600
420
600
ABS8
800
560
800
ABS10 UNITS
1000
700
1000
V
V
V
A
A
V
A
A
C/W
C
C
500
75
-55 +150
-55 +150
REV 1.0 2017 JAN
PAGE:1/2
RATING AND CHARACTERISTIC CURVES (ABS05 THRU ABS10)
FIG.1-TYPICAL FORWARD CURRENT
DERATING CURVE
1.2
1.0
0.8
0.6
0.4
0.2
Single Phase
Half Wave 60Hz
Resistive Or Inductive Load
FIG.2-MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
PEAK FORWAARD SURGE CURRENT,(A)
50
AVERAGE FORWARD CURRENT,(A)
40
30
Tj=25 C
8.3ms Single Half
Sine Wave
JEDEC method
20
10
0
25
50
75
100 125
150
175
AMBIENT TEMPERATURE ( C)
0
1
5
10
50
100
NUMBER OF CYCLES AT 60Hz
FIG.3-TYPICAL FORWARD
CHARACTERISTICS
50
INSTANTANEOUS FORWARD CURRENT,(A)
FIG.4-TYPICAL REVERSE
CHARACTERISTICS
50
T
J
=125
°C
REVERSE LEAKAGE CURRENT, (mA)
10
3.0
1.0
Tj=25 C
Pulse Width 300us
1% Duty Cycle
10
3.0
1.0
0.1
0.1
Tj=25 C
.01
.01
0
.2
.4
.6
.8
1.0
1.2
1.4
FORWARD VOLT
AGE,(V)
20
40
60
80
100 120 140
PERCENTAGE OF PEAK REVERSE VOLT
AGE, (%)
REV 1.0 2017 JAN
PAGE:2/2