BR1005
THRU
BR1010
SINGLE PHASE 10 AMP BRIDGE RECTIFIERS
VOLTAGE RANGE
50 to 1000 Volts
CURRENT
FEATURES
* Low forward voltage
* Low leakage current
* Mounting: Hole thru for #6 screw
* Mounting position: Any
.595
MIN.
(15.1)
10.0 Amperes
BR-10
.296(7.5)
.255(6.5)
* Both normal and Pb free product are available:
* Normal:80~95%Sn,5~20%Pb
* Pb free:99 Sn above can meet Rohs enviroment substance
directive request
.052(1.3) DIA.
.048(1.2) TYP.
.770(19.6)
.730(18.5)
HOLE FOR
NO. 6 SCREW
AC
.520(13.2) .770(19.6)
.480(12.2) .730(18.5)
AC
+
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating 25 C ambient temperature uniess otherwies specified.
Single phase half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
TYPE NUMBER
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
.375"(9.5mm) Lead Length at Tc=50 C
Peak Forward Surge Current, 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Maximum Forward Voltage Drop per Bridge Element at
10.0A
D.C.
Maximum DC Reverse Current
Ta=25 C
at Rated DC Blocking Voltage
Operating Temperature Range, T
J
Storage Temperature Range, T
STG
Ta=100 C
BR1005 BR101 BR102 BR104 BR106 BR108 BR1010 UNITS
50
100
200
400
600
800
1000
V
35
70
140
280
420
560
700
V
50
100
200
400
600
800
1000
V
10
200
1.1
10
200
-65 +150
-65 +150
A
A
V
µA
µA
C
C
174
RATING AND CHARACTERISTIC CURVES (BR1005 THRU BR1010)
FIG.1-TYPICAL FORWARD CURRENT
DERATING CURVE
12
10
8
6
4
2
0
Single Phase
Half Wave 60Hz
Resistive Or Inductive Load
FIG.2-MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
PEAK FORWARD SURGE CURRENT,(A)
250
AVERAGE FORWARD CURRENT,(A)
200
150
Tj=25 C
8.3ms Single Half
Sine Wave
JEDEC method
100
50
0
25
50
75
100 125
150
175
CASE TEMPERATURE,( C)
0
1
5
10
50
100
NUMBER OF CYCLES AT 60Hz
FIG.3-TYPICAL FORWARD
CHARACTERISTICS
50
INSTANTANEOUS FORWARD CURRENT,(A)
FIG.4-TYPICAL REVERSE
CHARACTERISTICS
50
3.0
1.0
Tj=25 C
Pulse Width 300us
1% Duty Cycle
REVERSE LEAKAGE CURRENT, (
µ
A)
10
10
3.0
1.0
0.1
0.1
Tj=25 C
.01
0
.2
.4
.6
.8
1.0
1.2
1.4
.01
0
20
40
60
80
100 120 140
FORWARD VOLTAGE,(V)
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
175