ER2000CT~ER2006CT
ISOLATION SUPERFAST RECOVERY RECTIFIER
VOLTAGE
FEATURES
• Plastic package has Underwriters Laboratory
Flammability Classification 94V-O.
Flame Retardant Epoxy Molding Compound.
• Exceeds environmental standards of MIL-S-19500/228
• Low power loss, high efficiency.
• Low forward voltage, high current capability
• High surge capacity.
• Super fast recovery times, high voltage.
• Epitaxial chip construction.
• Lead free in comply with EU RoHS 2011/65/EU directives
50 to 600 Volts
CURRENT
20.0 Amperes
MECHANICAL DATA
• Case: TO-220AB Molded plastic
• Terminals: Lead solderable per MIL-STD-750, Method 2026
• Polarity: As marked.
• Standard packaging: Any
• Weight: 0.0655 ounces, 1.859 grams.
MAXIMUM RATING AND ELECTRICAL CHARACTERISTICSS
Ratings at 25°C ambient temperature unless otherwise specified. Single phase, half wave, 60 Hz, resistive or inductive loa d.
For capacitive load, derate current by 20%
PARAMETER
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Current at T
C
=90
o
C
Peak Forward Surge Current : 8.3ms single half sine-wave
superimposed on rated load (JEDEC method)
Maximum Forward Voltage at 10A
Maximum DC Reverse Current at Rated DC Blocking
Voltage
Maximum Reverse Recovery Time (Note 2)
Typical Junction Capacitance (Note 1)
Typical thermal Resistance (Note 3)
Operating Junction and Storage Temperature Range
T
J
=25
O
C
T
J
=100
O
C
SYMBOL
V
RRM
V
RMS
V
DC
I
F(AV)
I
FSM
V
F
I
R
ER2000CT
ER2001CT
ER2001ACT
ER2002CT
ER2003CT
ER2004CT
ER2006CT
UNITS
V
V
V
A
A
50
35
50
100
70
100
150
105
150
200
140
200
20
150
300
210
300
400
280
400
600
420
600
0.95
1
500
35
85
3
-50 to +150
1.3
1.7
V
A
t
rr
C
J
R
Jc
T
J
,T
STG
50
100
ns
pF
O
C/W
O
C
NOTES:
1. Measured at 1 MHz and applied reverse voltage of 4.0 VDC.
2. Reverse Recovery Test Conditions: I
F
=.5A, I
R
=1A, Irr=.25A.
3. Both Bonding and Chip structure are available.
January 17 2013-REV.03
PAGE . 1
ER2000CT~ER2006CT
RATING AND CHARACTERISTIC CURVES
AVERAGE FORWARD CURRENT,
AMPERES
INSTANTANEOUS FORWARD CURRENT
AMPERES
20
16
12
6
RESISTIVEORINDUCTIVE LOAD
50
10
50-200V
300-400V
1.0
600V
4
0
0
20
40
60
80
100
O
T
J=
25 C
Pulse Width=200us
O
120
140
160
0.1
0.75
0.95
.
1.15
1.35
1.55
1.75
CASE TEMPERAURE, C
Fig.1- FORWARD CURRENT DERATING CURVE
INSTANTANEOUS FORWARD VOLTAGE, VOLTS
Fig.2- TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTIC
1000
PEAK FORWARD SURGE CURRENT,
180
150
120
90
60
25
0
8.3ms Single
Half Since-Wave
JEDEC Method
INVSTANTANEOUS REVERSE CURRENT,
MICROAMPERES
100
T
J
= 125 C
O
T
J
= 75 C
10
O
1
2
5
10
20
50
100
1.0
NO. OF CYCLE AT 60HZ
T
J
= 25 C
O
Fig.4- MAXIMUM NON - REPETITIVE SURGE CURRENT
0.1
20
40
60
80
100
120
90
PERCENT OF RATED PEAK INVERSE VOLTGE, VOLTS
80
FIG.3 TYPICAL REVERSE CHARACTERISTICS
CAPACITANCE, pF
70
60
T
J
= 25
O
C
50
40
30
20
10
1
2
5
10
20
50 100 200
500
REVERSE VOLTAGE, VOLTS
Fig.5- TYPICAL JUNCTION CAPACITANCE
January 17 2013-REV.03
PAGE . 2
ER2000CT~ER2006CT
Part No_packing code_Version
ER2000CT_T0_00001
ER2000CT_T0_10001
For example :
RB500V-40_R2_00001
Part No.
Serial number
Version code means HF
Packing size code means 13"
Packing type means T/R
Packing Code
XX
Packing type
Tape and Ammunition Box
(T/B)
Tape and Reel
(T/R)
Bulk Packing
(B/P)
Tube Packing
(T/P)
Tape and Reel (Right Oriented)
(TRR)
Tape and Reel (Left Oriented)
(TRL)
FORMING
1
st
Code
A
R
B
T
S
L
F
Packing size code
N/A
7"
13"
26mm
52mm
PANASERT T/B CATHODE UP
(PBCU)
PANASERT T/B CATHODE DOWN
(PBCD)
Version Code
XXXXX
2
nd
Code
HF or RoHS
1
st
Code 2
nd
~5
th
Code
0
1
2
X
Y
U
D
HF
RoHS
0
1
serial number
serial number
January 17 2013-REV.03
PAGE . 3
ER2000CT~ER2006CT
Disclaimer
•
Reproducing and modifying information of the document is prohibited without permission
from Panjit International Inc..
•
Panjit International Inc. reserves the rights to make changes of the content herein the
document anytime without notification. Please refer to our website for the latest
document.
•
Panjit International Inc. disclaims any and all liability arising out of the application or use of
any product including damages incidentally and consequentially occurred.
•
Panjit International Inc. does not assume any and all implied warranties, including warranties
of fitness for particular purpose, non-infringement and merchantability.
•
Applications shown on the herein document are examples of standard use and operation.
Customers are responsible in comprehending the suitable use in particular applications.
suitable for the specified use without further testing or modification.
Panjit International Inc. makes no representation or warranty that such applications will be
•
The products shown herein are not designed and authorized for equipments requiring high
level of reliability or relating to human life and for any applications concerning life-saving
or life-sustaining, such as medical instruments, transportation equipment, aerospace
machinery et cetera. Customers using or selling the products for use in such applications
se
do so at their own risk and agree to fully indemnify Panjit International Inc. for any damages
resulting from such improper use or sale.
•
Since Panjit uses lot number as the tracking base, please provide the lot number for tracking
when complaining.
January 17 2013-REV.03
PAGE . 4