ER2A~ER2J
SURFACE MOUNT RECTIFIER
VOLTAGE
FEATURES
0.155(3.94)
0.083(2.11)
0.075(1.91)
0.185(4.70)
0.160(4.06)
0.096(2.44)
0.050(1.27)
0.030(0.76)
0.220(5.59)
0.200(5.08)
50 to 600 Volts
CURRENT
2 Amperes
• High temperature metallurgically bonded-no compression
contacts as found in other diode-constructed rectifiers
• Glass passivated junction
• Easy pick and place
• Plastic package has Underwriters Laboratory Flammability
Classification 94V-O
•
Green molding compound as per IEC61249 Std. . (Halogen Free)
MECHANICAL DATA
• Case: JEDEC DO-214AA molded plastic
• Terminals: Solder plated, solderable per MIL-STD-750, Method 2026
• Polarity: Indicated by cathode band
• Standard packaging: 16mm tape (EIA-481)
• Weight: 0.0032 ounce, 0.093 gram
1
2
Cathode
Anode
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25°C ambient temperature unless otherwise specified. Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
PARAMETER
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Current at T
L
=110
O
C
Peak Forward Surge Current : 8.3ms single half sine-wave
superimposed on rated load(JEDEC method)
Maximum Forward Voltage at 2.0A
Maximum DC Reverse Current T
J
=25
O
C
at Rated DC Blocking VoltageT
J
=100
O
C
Maximum Reverse Recovery Time (Note 1)
Typical Junction capacitance (Note 2)
Typical thermal Resistance (Note 3)
Operating Junction and Storage Temperature Range
SYMBOL
V
R R M
V
R M S
V
D C
I
F (A V )
I
F S M
V
F
I
R
0.95
1.0
150
35
25
20
-55 to +150
O
ER2A
50
35
50
ER2B
100
70
100
0.083(2.13)
• Lead free in comply with EU RoHS 2002/95/EC directives
0.012(0.305)
0.006(0.152)
ER2C
150
105
150
ER2D
200
140
200
2.0
50
ER2E
300
210
300
ER2G
400
280
400
0.130(3.30)
• For surface mounted applications
ER2J
600
420
600
UNITS
V
V
V
A
A
1.25
1.7
V
μA
ns
pF
C/W
O
t
rr
C
J
R
θ
JL
T
J
,T
S T G
C
NOTES:1. Reverse Recovery Test Conditions: I
F
=0.5A, I
R
=1.0A, I
rr
=0.25A
2. Measured at 1 MHz and applied V
r
= 4.0 volts.
3. 8.0 mm
2
( .013mm thick ) land areas.
October 3,2012-REV.06
PAGE . 1
ER2A~ER2J
RATING AND CHARACTERISTIC CURVES
70
2.8
AVERAGE FORWARD RECIFIED
CURRENT AMPERES
2.4
CAPACITANCE, pF
60
50
40
30
20
10
2 .0
1.6
1 .2
.8
.4
0
0
20
40
60
80
100
120
O
SINGLE PHASE, HALF-WAVE, 60Hz RESISTIVE
OR INDUCTIVE LOAD P.C.B MOUNTED
ON 0.3 x 0.3" (8.0 x 8.0 mm)COPPER PAD AREAS
T
J
= 25 C
f = 1.0M
HZ
Vsig = 50mVp-p
0.1
1
10
100
1000
O
140
160
180
0
LEAD TEMPERATURE, C
REVERSE VOLTAGE, VOLTS
FIG.1 MAXIMUM AVERAGE FORWARD CURRENT RATING
FIG.2 TYPICAL JUNCTION CAPACITANCE
100
100
T
J
= 125 C
O
INSTANTANEOUS FORWARD CURRENT AMPERES
1000
INVSTANTANEOUS REVERSE CURRENT,
MICROAMPERES
10
50-200V
300-400V
T
J
= 75 C
10
O
1.0
600V
1.0
T
J
= 25 C
O
0.1
T
J
= 25 C
O
0.1
20
40
60
80
100
120
.01
0
PERCENT OF RATED PEAK INVERSE VOLTGE, VOLTS
0.4
0.8
1.2
1.6
2.0
2.4
2.8
INSTANTANEOUS FORWARD VOLTAGE VOLTS
FIG.3 TYPICAL REVERSE CHARACTERISTICS
FIG.4 TYPICAL FORWARD CHARACTERISTICS
60
FORWARD SURGE CURRENT, AMPERES
(HALF-SING WAVE)
50
40
30
20
10
0
1
8.3ms SINGLE HALF SINE-WAVE
JEDC METHOD
5
10
50
100
NUMBER OF CYCLES AT 60Hz
FIG.5 MAXIMUM NON-REPEITIVE SURGE CURRENT
October 3,2012-REV.06
PAGE . 2
ER2A~ER2J
MOUNTING PAD LAYOUT
ORDER INFORMATION
• Packing information
T/R - 3K per 13" plastic Reel
T/R - 0.5K per 7" plastic Reel
October 3,2012-REV.06
PAGE . 3
ER2A~ER2J
Part No_packing code_Version
ER2A_R1_00001
ER2A_R2_00001
For example :
RB500V-40_R2_00001
Part No.
Serial number
Version code means HF
Packing size code means 13"
Packing type means T/R
Packing Code
XX
Packing type
Tape and Ammunition Box
(T/B)
Tape and Reel
(T/R)
Bulk Packing
(B/P)
Tube Packing
(T/P)
Tape and Reel (Right Oriented)
(TRR)
Tape and Reel (Left Oriented)
(TRL)
FORMING
1
st
Code
A
R
B
T
S
L
F
Packing size code
N/A
7"
13"
26mm
52mm
PANASERT T/B CATHODE UP
(PBCU)
PANASERT T/B CATHODE DOWN
(PBCD)
Version Code
XXXXX
2
nd
Code
HF or RoHS
1
st
Code 2
nd
~5
th
Code
0
1
2
X
Y
U
D
HF
RoHS
0
1
serial number
serial number
October 3,2012-REV.06
PAGE . 4
ER2A~ER2J
Disclaimer
•
Reproducing and modifying information of the document is prohibited without permission
from Panjit International Inc..
•
Panjit International Inc. reserves the rights to make changes of the content herein the
document anytime without notification. Please refer to our website for the latest
document.
•
Panjit International Inc. disclaims any and all liability arising out of the application or use of
any product including damages incidentally and consequentially occurred.
•
Panjit International Inc. does not assume any and all implied warranties, including warranties
of fitness for particular purpose, non-infringement and merchantability.
•
Applications shown on the herein document are examples of standard use and operation.
Customers are responsible in comprehending the suitable use in particular applications.
suitable for the specified use without further testing or modification.
Panjit International Inc. makes no representation or warranty that such applications will be
•
The products shown herein are not designed and authorized for equipments requiring high
level of reliability or relating to human life and for any applications concerning life-saving
or life-sustaining, such as medical instruments, transportation equipment, aerospace
machinery et cetera. Customers using or selling these products for use in such applications
do so at their own risk and agree to fully indemnify Panjit International Inc. for any damages
resulting from such improper use or sale.
•
Since Panjit uses lot number as the tracking base, please provide the lot number for tracking
when complaining.
October 3,2012-REV.06