ER3A~ER3J
SURFACE MOUNT RECTIFIER
VOLTAGE
FEATURES
• For surface mounted applications
• High temperature metallurgically bonded-no compression
contacts as found in other diode-constructed rectifiers
• Glass passivated junction
• Built-in strain relief
• Easy pick and place
• Plastic package has Underwriters Laboratory Flammability
Classification 94V-O
•
Lead free in comply with EU RoHS 2002/95/EC directives
50 to 600 Volts
CURRENT
3.0 Amperes
MECHANICALDATA
• Case: JEDEC DO-214AB molded plastic
• Terminals: Solder plated, solderable per MIL-STD-750, Method 2026
• Polarity: Indicated by cathode band
• Standard packaging: 16mm tape (EIA-481)
• Weight: 0.0082 ounce, 0.2325 gram
1
2
Cathode
Anode
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25°C ambient temperature unless otherwise specified. Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
PA RA M E TE R
M a xi m um R e c ur r e nt P e a k R e ve r s e V o l t a g e
M a xi m um R M S V o l t a g e
M a xi m um D C B l o c k i ng V o l t a g e
M a xi m um A ve r a g e F o r w a r d C ur r e nt a t T
L
= 7 5
O
C
P e a k F o r w a r d S ur g e C ur r e nt : 8 . 3 m s s i ng l e ha l f s i ne - w a ve
s up e r i m p o s e d o n r a t e d l o a d ( J E D E C m e t ho d )
M a xi m um F o r w a r d V o l t a g e a t 3 . 0 A
M a xi m um D C R e ve r s e C ur r e nt T
J
= 2 5
O
C
a t R a t e d D C B l o c k i ng Vo l t a g e T
J
= 1 0 0
O
C
M a x i m u m R e v e r s e R e c o v e r y Ti m e ( N o t e 1 )
Ty p i c a l J u n c t i o n c a p a c i t a n c e ( N o t e 2 )
Ty p i c a l t h e r m a l R e s i s t a n c e ( N o t e 3 )
O p e r a t i n g a n d S t o r a g e Te m p e r a t u r e R a n g e
S YM B O L E R 3 A E R 3 B E R 3 C E R 3 D E R 3 E E R 3 G E R 3 J U N I T S
V
RRM
V
RMS
V
D C
I
F ( A V )
I
F S M
V
F
I
R
t
rr
C
J
R
θ
J L
T
J
, T
S T G
0 .9 5
1 .0
200
35
45
O
50
35
50
100
70
100
150
105
150
200
140
200
3 .0
100
300
210
300
400
280
400
600
420
600
V
V
V
A
A
1 .2 5
1 .7
V
µ
A
ns
pF
C /
W
C
16
-5 5 to +1 5 0
O
NOTES:1. Reverse Recovery Test Conditions: I
F
=0.5A, I
R
=1.0A, I
rr
=0.25A
2. Measured at 1 MHz and applied V
r
= 4.0 volts.
3. 8.0 mm
2
( .013mm thick ) land areas.
STAD-MAR.06.2009
PAGE . 1
ER3A~ER3J
RATING AND CHARACTERISTIC CURVES
100
AVERAGE FORWARD RECIFIED
CURRENT AMPERES
90
80
T
J
= 25 C
f = 1.0M
HZ
Vsig = 50mVp-p
O
3
CAPACITANCE, pF
70
60
50
40
30
20
10
0
0.1
1
10
100
1000
2
1
SINGLE PHASE, HALF-WAVE, 60Hz RESISTIVE
OR INDUCTIVE LOAD P.C.B MOUNTED
ON 0.3 x 0.3" (8.0 x 8.0 mm)COPPER PAD AREAS
0
20
40
60
80
100
120
O
0
140
160
180
REVERSE VOLTAGE, VOLTS
LEAD TEMPERATURE, C
FIG.1 TYPICAL JUNCTION CAPACITANCE
FIG.2 MAXIMUM AVERAGE FORWARD CURRENT RATING
1000
INSTANTANEOUS FORWARD CURRENT AMPERES
100
INVSTANTANEOUS REVERSE CURRENT,
MICROAMPERES
100
T
J
= 125 C
O
50-200V
10
T
J
= 75 C
10
O
300-400V
1.0
600V
1.0
T
J
= 25 C
O
0.1
T
J
=25 C
PULSE WIDTH= 300
m
S
2% DUTY CYCLE
0.01
0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
O
0.1
20
40
60
80
100
120
PERCENT OF RATED PEAK INVERSE VOLTGE, VOLTS
INSTANTANEOUS FORWARD VOLTAGE VOLTS
FIG.3 TYPICAL REVERSE CHARACTERISTICS
FIG.4 TYPICAL FORWARD CHARACTERISTICS
110
FORWARD SURGE CURRENT,
AMPERES
100
90
80
70
60
50
1
8.3ms SINGLE HALF SINE-WAVE
JEDC METHOD
5
10
50
100
NUMBER OF CYCLES AT 60Hz
FIG.5 MAXIMUM NON-REPEITIVE SURGE CURRENT
STAD-MAR.06.2009
PAGE . 2
ER3A~ER3J
MOUNTING PAD LAYOUT
ORDER INFORMATION
• Packing information
T/R - 3K per 13" plastic Reel
T/R - 0.5Kper 7” plastic Reel
STAD-MAR.06.2009
PAGE . 3
ER3A~ER3J
For example :
RB500V-40_R2_00001
Serial number
Part No.
Version code means HF
Packing size code means 13"
Packing type means T/R
Packing Code
XX
Packing
type
T/B
T/R
B/P
T/P
TRR
TRL
FORMING
1
st
Code
A
R
B
T
S
L
F
Packing
2
nd
Code
size code
N/A
7"
13"
26mm
52mm
PBCU
PBCD
0
1
2
X
Y
U
D
Version Code
XXXXX
HF or RoHS
1
st
Code
HF
RoHS
0
1
2
nd
~5
th
Code
serial number
serial number
Part No_packing code_Version
ER3A_R1_00001
ER3A_R1_10001
ER3A_R2_00001
ER3A_R2_10001
STAD-MAR 06,2009
PAGE . 4
ER3A~ER3J
Disclaimer
Reproducing and modifying information of the document is prohibited without
permission from Panjit International Inc..
Panjit International Inc. reserves the rights to make changes of the content herein the
document anytime without notification. Please refer to our website for the latest
document.
Panjit International Inc. disclaims any and all liability arising out of the application or
use of any product including damages incidentally and consequentially occurred.
Panjit International Inc. does not assume any and all implied warranties, including
warranties of fitness for particular purpose, non-infringement and merchantability.
Applications shown on the herein document are examples of standard use and
operation. Customers are responsible in comprehending the suitable use in particular
applications. Panjit International Inc. makes no representation or warranty that such
applications will be suitable for the specified use without further testing or modification.
The products shown herein are not designed and authorized for equipments requiring
high level of reliability or relating to human life and for any applications concerning
life-saving or life-sustaining, such as medical instruments, transportation equipment,
aerospace machinery et cetera. Customers using or selling these products for use in
such applications do so at their own risk and agree to fully indemnify Panjit
International Inc. for any damages resulting from such improper use or sale.
STAD-MAR.06.2009
PAGE . 5