ER800F~ER804F
SUPERFAST RECOVERY RECTIFIERS
VOLTAGE
FEATURES
• Superfast recovery times-epitaxial construction.
• Low forward voltage, high current capability.
• Exceeds environmental standards of MIL-S-19500/228.
• Hermetically sealed.
• Low leakage.
• High surge capability.
• Plastic package has Underwriters Laboratories
Flammability Classification 94V-O utilizing
Flame Retardant Epoxy Molding Compound.
•
Lead free in comply with EU RoHS 2002/95/EC directives
50 to 400 Volts
CURRENT
8.0 Amperes
MECHANICALDATA
• Case: Molded plastic, ITO-220AC
• Terminals: Axial leads, solderable to MIL-STD-750,Method 2026
• Polarity: As marking
• Weight:
0.055 ounces, 1.5615 grams.
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25°C ambient temperature unless otherwise specified.
Resistive or inductive load, 60Hz.
PA RA M E TE R
M a xi m um R e c ur r e nt P e a k R e ve r s e V o l t a g e
M a xi m um R M S V o l t a g e
M a xi m um D C B l o c k i ng V o l t a g e
M a xi m um A ve r a g e F o r w a r d C ur r e nt a t T
C
= 7 5
O
C
P e a k F o r w a r d S ur g e C ur r e nt , 8 . 3 m s s i ng l e ha l f s i ne - w a ve
s up e r i m p o s e d o n r a t e d l o a d ( J E D E C m e t ho d )
M a xi m um F o r w a r d V o l t a g e a t 8 . 0 A ( N o t e 1 )
M a xi m um D C R e ve r s e C ur r e nt T
J
= 2 5
O
C
a t R a t e d D C B l o c k i ng Vo l t a g e T
J
= 1 0 0
O
C
M a x i m u m R e v e r s e R e c o v e r y Ti m e ( N o t e 1 )
Ty p i c a l J u n c t i o n c a p a c i t a n c e ( N o t e 2 )
Ty p i c a l t h e r m a l R e s i s t a n c e ( N o t e 3 )
O p e r a t i n g J u n c t i o n a n d S t o r a g e Te m p e r a t u r e R a n g e
S YM B O L
E R 8 0 0 F E R 8 0 1 F E R 8 0 1 A F E R 8 0 2 F E R 8 0 3 F E R 8 0 4 F
U N I T S
V
RRM
V
RMS
V
D C
I
F ( A V )
I
F S M
V
F
I
R
t
rr
C
J
R
θ
J C
T
J
, T
S T G
35
65
O
50
35
50
100
70
100
150
105
150
8 .0
125
0 .9 5
1 .0
300
200
140
200
300
210
300
400
280
400
V
V
V
A
A
1 .3
V
µ
A
50
ns
pF
C /
W
C
3 .0
-5 5 to +1 5 0
O
NOTES:
1. Pulse Test with PW=300 usec, 2% Duty Cycle.
2. Reverse Recovery Tset Conditions:I
F
=0.5A,I
R
=1.0A,Irr=0.25A
3. Mounted on P.C. Board with 14mm2 (.013mm thick) copper pad areas.
STAD-MAR.06.2009
PAGE . 1
ER800F~ER804F
RATING AND CHARACTERISTIC CURVES
AVERAGE FORWARD CURRENT,
AMPERES
10.0
8.0
6.0
4.0
2.0
0
0
PEAK FORWARD SURGE CURRENT
,
AMPERES
100
80
60
60
40
20
0
1
10
NO. OF CYCLE AT 60HZ
50
100
150
100
CASE TEMPERATURE,
O
C
Fig.1-FORWARD CURRENT DERATING CURVE
Fig.2-MAXIMUM NON-REPETITIVE SURGE CURRENT
1000
100
T
J
= 125 C
O
INST
ANTANEOUS FORWARD CURRENT
AMPERES
40
INVSTANTANEOUS REVERSE CURRENT,
MICROAMPERES
10
200V
300-400V
T
J
= 75 C
10
O
1
1.0
T
J
= 25 C
O
T
J
=25 C
Pulse Width=300us
.1
O
0.1
20
40
60
80
100
120
.6
.8
1.0
1.2
1.4
1.6
1.8
2.0
PERCENT OF RATED PEAK INVERSE VOLTGE, VOLTS
INST
ANTANEOUS FORWARD VOLTAGE, VOLTS
Fig.3-TYPICAL REVERSE CHARACTERISTICS
Fig.4-TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS
STAD-MAR.06.2009
PAGE . 2
ER800F~ER804F
Part No_packing code_Version
ER800F_T0_00001
ER800F_T0_10001
For example :
RB500V-40_R2_00001
Part No.
Serial number
Version code means HF
Packing size code means 13"
Packing type means T/R
Packing Code
XX
Packing type
Tape and Ammunition Box
(T/B)
Tape and Reel
(T/R)
Bulk Packing
(B/P)
Tube Packing
(T/P)
Tape and Reel (Right Oriented)
(TRR)
Tape and Reel (Left Oriented)
(TRL)
FORMING
1
st
Code
A
R
B
T
S
L
F
Packing size code
N/A
7"
13"
26mm
52mm
PANASERT T/B CATHODE UP
(PBCU)
PANASERT T/B CATHODE DOWN
(PBCD)
Version Code
XXXXX
2
nd
Code
HF or RoHS
1
st
Code 2
nd
~5
th
Code
0
1
2
X
Y
U
D
HF
RoHS
0
1
serial number
serial number
STAD-MAR.06.2009
PAGE . 3
ER800F~ER804F
Disclaimer
Reproducing and modifying information of the document is prohibited without
permission from Panjit International Inc..
Panjit International Inc. reserves the rights to make changes of the content herein the
document anytime without notification. Please refer to our website for the latest
document.
Panjit International Inc. disclaims any and all liability arising out of the application or
use of any product including damages incidentally and consequentially occurred.
Panjit International Inc. does not assume any and all implied warranties, including
warranties of fitness for particular purpose, non-infringement and merchantability.
Applications shown on the herein document are examples of standard use and
operation. Customers are responsible in comprehending the suitable use in particular
applications. Panjit International Inc. makes no representation or warranty that such
applications will be suitable for the specified use without further testing or modification.
The products shown herein are not designed and authorized for equipments requiring
high level of reliability or relating to human life and for any applications concerning
life-saving or life-sustaining, such as medical instruments, transportation equipment,
aerospace machinery et cetera. Customers using or selling these products for use in
such applications do so at their own risk and agree to fully indemnify Panjit
International Inc. for any damages resulting from such improper use or sale.
STAD-MAR.06.2009
PAGE . 4