100, 120 and 240 Vac: +10%, -13%; 215 Vac: +12%, -11%; 47 to 63Hz. Toler-
ance for 230 Vac operation is +15%, -10%. Derate output current 10% for 50
Hz operation.
Dc Output
See voltage rating chart. Adjustment range ±5% minimum except HA series.
Line Regulation
±0.05% for a 10% change.
Load Regulation
± 0.05% for a 50% load change.
Output Ripple
3 mV +0.05% of output voltage, peak to peak maximum. All “3-terminal regu-
lator” outputs: 3 mV +0.2% peak to peak maximum.
Transient Response
<50 microseconds for 50% load change.
Short Circuit Protection
Automatic current limit/foldback.
Overvoltage Protection
Built-in on all 5 V models, set at 6.2 V ±0.4 V. Other models use optional over-
voltage protection.
Remote Sensing
Provided on all models; open sense lead protection built-in (except HA & HTAA
series).
Stability
±0.05% for 24 hours after warmup.
Temperature Rating
0 to 50°C full rated, derated linearly to 40% at 70°C.
Temperature Coefficient
±0.01%/°C maximum.
Efficiency
5 V units: 45%; 12 and 15 V units: 55%; 20 and 24 V units: 60%.
Logic Inhibit and Current-Share
F & G models.
Medical Stock and Vibration
Per Mil-Std-810D, Method 514.3, Category 1, Procedure 1.
Per Mil-Std-810D, Method 516.3, Procedure III.
Storage
-40 to +85 °C.
All specifications are typical at nominal input, full load at 25
O
C unless otherwise stated
Commercial Model (Single)
HB2-3-A+G
HC2-6-A+G
HE2-18-A+G
Medical Model
Voltage
2V
2V
2V
Current
3A
6A
18 A
1.0 A
1.5 A
3A
6A
9A
12 A
18 A
25 A
35 A
50 A
0.5 A
0.9 A
1.7 A
3.4 A
5.1 A
6.8 A
10.2 A
.4 A
0.9 A
1.5 A
3A
4.5 A
6A
9A
15 A
0.5 A
1.2 A
2.4 A
3.6 A
4.8 A
7.2 A
12 A
0.5 A
1A
2A
3A
4A
6A
10 A
0.5 A
1A
3A
4A
6A
Case
B
C
E
L
B
B
C
N
D
E
F
G
G
L
B
B
C
N
D
E
L
B
B
C
N
D
E
F
B
B
C
N
D
E
F
B
B
C
N
D
E
F
B
C
D
E
F
ML5-1-OV-A
HA5-1.5-OV-A+G
HB5-3-OV-A+G
HC5-6-OV-A+G
HN5-9-OV-A+G
HD5-12-OV-A+G
HE5-18-OV-A+G
F5-25-OV-A+*G
G5-35-OV-A+ *
(1)
CP197-A+G
ML12-0.5-A
HA15-0.9-A+ (12 V)G
HB12-1-7-A+G
HC12-3.4-A+G
HN12-5.1-A+G
HD12-6.8-A+G
HE12-10-2-A+G
ML15-0.4-A
HA15-0.9-A+G
HB15-1.5-A+G
HC15-3-A+G
HN15-4.5-A+G
HD15-6-A+G
HE15-9-A+G *
F15-15-A+G *
HA24-0.5-A+G
HB24-1.2-A+G
HC24-2.4-A+G
HN24-3.6-A+G
HD24-4.8-A+G
HE24-7.2-A+G *
F24-12-A+G *
HA24-0.5-A+ (28 V)G
HB28-1-A+G
HC28-2-A+G
HN28-3-A+G
HD28-4-A+G
HE28-6-A+G *
F24-12-A+(28 V)G *
HB48-0.5-A+G
HC48-1-A+G
HD48-3-A+G **
HE48-4-A+G
F48-6-A+G *
Notes:
1. All single output models have isolated outputs.
2. Model G5-50-OV-A+ not RoHS compliant
MD28-4-A
MB28-1-A
MC28-2-A
MD24-4.8-A
MB24-1.2-A
MC24-2.4-A
MD15-6-A
MB15-1.5-A
MC15-3-A
MD12-6.8-A
MB12-1-7-A
MC12-3.4-A
5V
5V
5V
5V
5V
5V
5V
5V
5V
5V
12 V
12 V
12 V
12 V
12 V
12 V
12 V
15 V
15 V
15 V
15 V
15 V
15 V
15 V
15 V
24 V
24 V
24 V
24 V
24 V
24 V
24 V
28 V
28 V
28 V
28 V
28 V
28 V
28 V
48 V
48 V
48 V
48 V
48 V
Commercial Model (Dual)
HAA5-1.5-OV-A+G
HBB5-3-OV-A+G
HCC5-6-OV-A+G
HAA512-A+G
HBB512-A+G
HCC512-A+G **
HAA524-A+G **
HBB524-A+G
HCC524-A+G
HAD12-0.4-A+G
Medical Model
Output 1
5 V @ 1.5 A
5V@3A
5V@6A
Output 2
5 V @ 1.5 A
5V@3A
5V@6A
9 to 15 V (adj) @ 0.5 A
9 to 15 V (adj) @ 1.2 A
9 to 15 V (adj) @ 2.5 A
18 to 24 V (adj) @ 0.3 A
18 to 24 V (adj) @ 0.8 A
18 to 24 V (adj) @ 2 A
-12 V @ 0.4 A
-12 V @ 0.25 A
-15 V @ 0.2 A
-15 V @ 0.4 A
-15 V @ 0.8 A ***
-15 V @ 1.5 A ***
-15 V @ 3 A ***
-15 V @ 5 A ***
-18 to 24 V @ 0.4/0.6 A
+12 V @ 4 A
Case
AA
BB
CC
AA
BB
CC
AA
BB
CC
B
L
L
B
AA
BB
CC
E
AA
BB
MAA512-A
MBB512-A
MCC512-A
MAA524-A
MBB524-A
MCC524-A
MLL12-0.25-A
MLL15-0.2-A
5V@2A
5V@3A
5V@6A
5V@2A
5V@3A
5V@6A
+12 V @ 0.4 A
+12 V @ 0.25 A
+15 V @ 0.2 A
+15 V @ 0.4 A
+15 V @ 0.8 A
+15 V @ 1.5 A
+15 V @ 3 A
+15 V @ 5 A
+18 to 24 V @ 0.4/0.6 A
+5 V @ 2 A
HAD15-0.4-A+G
HAA15-0.8-A+G
HBB15-1.5-A+G
HCC15-3-A+G
HDD15-5-A+G
HAA24-0.6-A+G
CP323-A+G
** May require fan cooling
*** No. 2 output usable at -5 V, rate at 1/2 of 15 V current rating.
Commercial Model (Triple)
HTAA-16W-A+G
HBAA40W-A+G
HCBB105W-A+G **
HCAA60W-A+G
HCBB75W-A+G
CP131-A+G
HDBB105W-A+G *
HDCC150W-A+G *
MCAA60W-A
MCBB75W-A
Medical Model
MTLL-5W-A
MTAA-16W-A
MBAA40W-A
Output 1
5 V @ 0.5 A
5V@2A
5V@3A
5V@3A
5V@6A
5V@6A
5V@8A
5 V @ 12 A
5 V @ 12 A
MAA15-0.8-A
MBB15-1.5-A
MCC15-3-A
Output 2
+12 to 15 V @ 0.1 A
+12 to 15 V @ 0.4/0.4 A
+12 to 15 V @ 1/0.8 A
+12 to 15 V @ 3.4/3.0 A
+12 to 15 V @ 1/0.8 A
+12 to 15 V @ 1.7/1.5 A
+12 to 15 V @ 1.7/1.5 A
+12 to 15 V @ 1.7/1.5 A
+12 to 15 V @ 3.4/3 A
Output 3
-12 to 15 V @ 0.1 A***
-12 to 15 V @ 0.4/0.4 A***
-12 to 15 V @ 1/0.8 A***
-12 to 15 V @ 3.4/3.0 A***
-12 to 15 V @ 1/0.8 A***
-12 to 15 V @ 1.7/1.5 A***
-12 to 15 V @ 1.7/1.5 A***
-12 to 15 V @ 1.7/1.5 A***
-12 to 15 V @ 3.4/3 A***
Case
L
AA
BAA
CBB
D
CBB
NBB
DBB
DCC
*Requires fan cooling
** May require fan cooling
***No. 3 output usable at -5 V, rate at 1/2 of 15 V current rating.
Outputs rated at 9 to 15V, 12 to 15V, or 18 to 24V are user adjustable outputs.
All outputs without + or - sign are isolated outputs and may be referenced as either a positive or negative output.
FIXED DISK SERIES
Both models without UL, CSA or TUV
Commercial Model (Dual)
CP379-A+G
CP498-A+G
Output 1
+5 V @ 6 A
+5 V @ 6 A
Output 2
+ 24 V @ 3.5/6 A PK
+ 12 V @ 5/10 A PK
Output 3
-5 or -12 @ 1.2 A
-12 V @ 0.5 A
Case
NBB
NBB
SL Power Electronics, Inc. 6050 King Drive, Bldg A, Ventura, CA, 93003, USA. Phone: (805) 486 4565 Fax: (805) 487 8911 Email: info@slpower.com. www.slpower.com Rev.