MBR3040CT SERIES
SCHOTTKY BARRIER RECTIFIERS
VOLTAGE
FEATURES
• Plastic package has Underwriters Laboratory
Flammability Classification 94V-O.
Flame Retardant Epoxy Molding Compound.
• Metal silicon junction, majority carrier conduction
• Low power loss, high efficiency.
• High current capability
• For use in low voltage, high frequency inverters
free wheeling, and polarlity protection applications.
• Lead free in comply with EU RoHS 2011/65/EU directives
40 to 200 Volts
CURRENT
30 Amperes
MECHANICAL DATA
• Case: TO-220AB molded plastic
• Terminals: solder plated, solderable per MIL-STD-750, Method 2026
• Polarity: As marked.
• Mounting Position: Any
• Weight: 0.0655 ounces, 1.859 grams.
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25°C ambient temperature unless otherwise specified. Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%
PA RA ME TE R
Ma xi mum Re curre nt P e ak Re ve rse Voltag e
Ma xi mum RMS Vo lta g e
Ma xi mum D C B lo cki ng Vo lta ge
Ma xi mum A vera g e F o rwa rd C urre nt
P e ak Fo rward S urg e C urre nt
:
8.3 ms si ng le
ha lf si ne-wa ve sup e ri mp o se d o n ra te d lo a d
(JE D E C metho d )
Ma xi mum F o rwa rd Vo lta ge at 1 5A p e r leg
Ma xi mum D C Re ve rse C urrent
at Ra te d D C B lo cki ng Voltag e
Typ i cal Therma l Resi sta nce
Op erati ng Juncti o n a nd S to ra ge Te mp e ra ture
Ra ng e
T
J
=25
O
C
T
J
=12 5
O
C
S YMB OL
V
RRM
V
RMS
V
DC
I
F(AV)
I
FS M
V
F
I
R
R
θJC
T
J
,T
STG
MB R30 40 CT MB R3 04 5C T MB R30 50 CT MB R30 60 CT MBR3 08 0C T MB R3 09 0C T MB R3 01 00 C T MBR3 01 50C T MB R30 20 0C T
UNITS
V
V
V
A
40
28
40
45
31 .5
45
50
35
50
60
42
60
80
56
80
30
90
63
90
1 00
70
1 00
15 0
10 5
15 0
2 00
140
2 00
275
A
0 .7
0 .7 5
0 .1
20
1 .4
0 .8
0.0 5
20
0.9
V
mA
O
C /W
O
-5 5 to + 1 50
-6 5 to + 1 75
C
Note :
Both Bonding and Chip structure are available.
January 3,2013-REV.05
PAGE . 1
MBR3040CT SERIES
RATING AND CHARACTERISTIC CURVES
275
250
AVERAGE FORWARD RECTIFIED
CURRENT AMPERES
40V
45-200V
PEAK FORWARD SURGE CURRENT,
AMPERES
50
40
30
20
10
0
0
20
40
60
80
100
120
140
225
200
175
150
125
100
75
50
25
0
1
2
5
10
20
50
100
RESISTIVE OR
INDUCTIVE LOAD
160
180
LEAD TEMPERATURE, C
Fig.1- FORWARD CURRENT DERATING CURVE
O
NO. OF CYCLE AT 60Hz
Fig.2- MAXIMUM NON-REPETITIVE SURGE
CURRENT
10
INSTANTANEOUS REVERSE CURRENT, mA
TC=125
O
C
1.0
INSTANTANEOUS FORWARD CURRENT,
AMPERES
40
10
8
6
4
2
1.0
0.8
0.6
0.4
0.2
0 .1
0.1
TC=75
O
C
0.01
TC=25 C
O
40-45V
50-60V
80-100V
150-200V
0 .001
0
20
40
60
80
100
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.1
PERCENT OF INSTANTANEOUS REVERSE VOLTAGE, %
INSTANTANEOUS FORWARD VOLTAGE, VOLTS
Fig.3- TYPICAL REVERSE CHARACTERISTIC
Fig.4- TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTIC
January 3,2013-REV.05
PAGE . 2
MBR3040CT SERIES
Part No_packing code_Version
MBR3040CT_T0_00001
MBR3040CT_00001
MBR3040CT_T0_10001
MBR3040CT_10001
For example :
RB500V-40_R2_00001
Serial number
Part No.
Version code means HF
Packing size code means 13"
Packing type means T/R
Packing Code
XX
Packing type
Tape and Ammunition Box
(T/B)
Tape and Reel
(T/R)
Bulk Packing
(B/P)
Tube Packing
(T/P)
Tape and Reel (Right Oriented)
(TRR)
Tape and Reel (Left Oriented)
(TRL)
FORMING
1
st
Code
A
R
B
T
S
L
F
Packing size code
N/A
7"
13"
26mm
52mm
PANASERT T/B CATHODE UP
(PBCU)
PANASERT T/B CATHODE DOWN
(PBCD)
Version Code
XXXXX
2
nd
Code
HF or RoHS
1
st
Code 2
nd
~5
th
Code
0
1
2
X
Y
U
D
HF
RoHS
0
1
serial number
serial number
January 3,2013-REV.05
PAGE . 3
MBR3040CT SERIES
Disclaimer
•
Reproducing and modifying information of the document is prohibited without permission
from Panjit International Inc..
•
Panjit International Inc. reserves the rights to make changes of the content herein the
document anytime without notification. Please refer to our website for the latest
document.
•
Panjit International Inc. disclaims any and all liability arising out of the application or use of
any product including damages incidentally and consequentially occurred.
•
Panjit International Inc. does not assume any and all implied warranties, including warranties
of fitness for particular purpose, non-infringement and merchantability.
•
Applications shown on the herein document are examples of standard use and operation.
Customers are responsible in comprehending the suitable use in particular applications.
Panjit International Inc. makes no representation or warranty that such applications will be
suitable for the specified use without further testing or modification.
•
The products shown herein are not designed and authorized for equipments requiring high
level of reliability or relating to human life and for any applications concerning life-saving
or life-sustaining, such as medical instruments, transportation equipment, aerospace
machinery et cetera. Customers using or selling these products for use in such applications
do so at their own risk and agree to fully indemnify Panjit International Inc. for any damages
resulting from such improper use or sale.
•
Since Panjit uses lot number as the tracking base, please provide the lot number for tracking
when complaining.
January 3,2013-REV.05
PAGE . 4