PMURT1060FCT
SUPERFAST RECOVERY RECTIFIERS
Voltage
Features
Superfast recovery times-epitaxial construction
Low forward voltage, high current capability
Hermetically sealed.
Low leakage
High surge capacity
Plastic package has Underwriters Laboratory
Flammability Classification 94V-O utilizing
Flame Retardant Epoxy Molding Compound
Lead free in compliance with EU RoHS 2011/65/EU directive
Green molding compound as per IEC61249 Std. .(Halogen Free)
600 V
Current
10 A
ITO-220AB
Unit: inch(mm)
Mechanical Data
Case: Molded plastic, ITO-220AB
Terminals: Solder plated, solderable per MIL-STD-750, Method 2026
Approx. Weight: 0.056 ounces, 1.6 grams
Maximum Ratings
(T
A
=25 C unless otherwise noted)
PARAMETER
Maximum repetitive peak reverse voltage
Maximum rms voltage
Maximum dc blocking voltage
Maximum average forward current
per device
SYMBOL
V
RRM
V
RMS
V
R
I
F(AV)
I
FSM
V
F
I
R
R
θJC
T
RR
T
J,
T
STG
VALUE
600
420
600
10
5
95
1.7
1
6.5
35
-55 to +175
o
o
UNIT
V
V
V
A
A
V
A
C/W
ns
o
per diode
Peak forward surge current : 8.3ms single half sine-
wave superimposed on rated load
Maximum forward voltage at 5A
Maximum dc reverse current at rated dc blocking
voltage
Typical Thermal Resistance per diode (Note 2)
Maximum reverse recovery time (Note 1)
Operating and storage temperature range
C
Note : 1. Reverse Recovery Test Conditions : I
F
=0.5A, I
R
=-1A, Recover to -0.25A
2. Device mounted on a infinite heatsink , then measured the center of the marking side.
October 17,2016-REV.01
Page 1
PMURT1060FCT
TYPICAL CHARACTERISTIC CURVES
Fig.1 Forward Current Derating Curve
Fig.2 Typical Junction Capacitance
Fig.3 Typical Reverse Characteristics
Fig.4 Typical Forward Characteristics
Part No Packing Code Version
Part No Packing Code
MURT1060FCT_T0_00001
Package Type
ITO-220AB
Packing Type
50pcs / Tube
Marking
MURT1060FCT
Version
Halogen free
October 17,2016-REV.01
Page 2
PMURT1060FCT
Disclaimer
● Reproducing and modifying information of the document is prohibited without permission from Panjit International Inc..
● Panjit International Inc. reserves the rights to make changes of the content herein the document anytime without
notification. Please refer to our website for the latest document.
● Panjit International Inc. disclaims any and all liability arising out of the application or use of any product including
damages incidentally and consequentially occurred.
● Panjit International Inc. does not assume any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
● Applications shown on the herein document are examples of standard use and operation. Customers are responsible in
comprehending the suitable use in particular applications. Panjit International Inc. makes no representation or warranty
that such applications will be suitable for the specified use without further testing or modification.
● The products shown herein are not designed and authorized for equipments requiring high level of reliability or relating to
human life and for any applications concerning life-saving or life-sustaining, such as medical instruments, transportation
equipment, aerospace machinery et cetera. Customers using or selling these products for use in such applications do so
at their own risk and agree to fully indemnify Panjit International Inc. for any damages resulting from such improper use or
sale.
● Since Panjit uses lot number as the tracking base, please provide the lot number for tracking when complaining.
October 17,2016-REV.01
Page 3