PG100R~PG1010R
GLASS PASSIVATED JUNCTION FAST RECOVERY RECTIFIERS
VOLTAGE
FEATURES
• High current capability.
• Plastic package has Underwriters Laboratories
Flammability Classification 94V-O utilizing
Flame Retardant Epoxy Molding Compound.
• Low leakage.
• Lead free in compliance with EU RoHS 201
1/65/EU directive
0.205(5.2)
0.160(4.1)
0.034(0.86)
0.028(0.71)
50 to 1000 Volt
CURRENT
1 Ampere
• Fast switching for high efficiency.
MECHANICAL DATA
• Case: Molded plastic, DO-41
• Terminals: Axial leads, solderable per MIL-STD-750,Method 2026
• Polarity: Color band denotes cathode end
• Weight: 0.0118 ounce, 0.336 gram
1
Cathode
2
Anode
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25°C ambient temperature unless otherwise specified. Resistive or inductive load, 60Hz.
PARAM ETER
M aximum Recur r ent Pea k Rever se Volt age
M aximum RM S V olt age
M aximum DC B locking Volt age
M aximum Aver age F or w ar d Cur r ent 0. 375"( 9. 5mm)
lea d lengt h at T
A
= 55
O
C
Peak F or w ar d Sur ge C ur r ent : 8. 3ms s ingle half s ine- w ave
super imposed on r at ed load
M aximum F or w ar d Vo lt age at 1A
M aximum DC Re ve r se Cur r ent a t a t Ra t ed DC
Blocking Volt age
Typical J unct ion C apacit ance ( Not e 1)
M aximum Re ver se R ecover y Time
Typical T her mal Resist ance
O per a ting a nd St or age Temper at ur e R ang e
T
J
= 25
O
C
T
J
= 100
O
C
SY M BO L
V
RRM
V
RMS
V
DC
I
F(AV)
I
FSM
V
F
I
R
C
J
t
rr
R
θJA
T
J
, T
STG
PG 1 00R
50
35
50
PG 10 1R
100
70
100
PG 102R
200
140
200
PG 104 R
400
280
400
1
30
1. 3
1
150
12
1.0(25.4)MIN.
0.107(2.7)
0.080(2.0)
PG 106R
60 0
42 0
60 0
PG 1 08R
800
560
800
PG 1010R
1000
700
1000
UNI TS
V
V
V
A
A
V
μA
pF
150
67
- 55 t o + 150
25 0
500
O
ns
C/
W
C
O
NOTES:1. Reverse recovery test conditions: I
F
=0.5A, I
R
=1A, I
rr
=0.25A
2. Measured at 1 MHz and applied reverse voltage of 4 VDC
3. Thermal resistance from junction to ambient and from junction to lead length 0.375"(9.5mm) P.C.B. mounted
May 4,2015-REV.05
PAGE . 1
PG100R~PG1010R
May 4,2015-REV.05
PAGE . 2
PG100R~PG1010R
Part No_packing code_Version
PG100R_AY_00001
PG100R_AY_10001
PG100R_B0_00001
PG100R_B0_10001
PG100R_R2_00001
PG100R_R2_10001
For example :
RB500V-40_R2_00001
Part No.
Serial number
Version code means HF
Packing size code means 13"
Packing type means T/R
Packing Code
XX
Packing type
Tape and Ammunition Box
(T/B)
Tape and Reel
(T/R)
Bulk Packing
(B/P)
Tube Packing
(T/P)
Tape and Reel (Right Oriented)
(TRR)
Tape and Reel (Left Oriented)
(TRL)
FORMING
1
st
Code
A
R
B
T
S
L
F
Packing size code
N/A
7"
13"
26mm
52mm
PANASERT T/B CATHODE UP
(PBCU)
PANASERT T/B CATHODE DOWN
(PBCD)
Version Code
XXXXX
2
nd
Code
HF or RoHS
1
st
Code 2
nd
~5
th
Code
0
1
2
X
Y
U
D
HF
RoHS
0
1
serial number
serial number
May 4,2015-REV.05
PAGE . 3
PG100R~PG1010R
Disclaimer
•
Reproducing and modifying information of the document is prohibited without permission
from Panjit International Inc..
•
Panjit International Inc. reserves the rights to make changes of the content herein the
document anytime without notification. Please refer to our website for the latest
document.
•
Panjit International Inc. disclaims any and all liability arising out of the application or use of
any product including damages incidentally and consequentially occurred.
•
Panjit International Inc. does not assume any and all implied warranties, including warranties
of fitness for particular purpose, non-infringement and merchantability.
•
Applications shown on the herein document are examples of standard use and operation.
Customers are responsible in comprehending the suitable use in particular applications.
suitable for the specified use without further testing or modification.
Panjit International Inc. makes no representation or warranty that such applications will be
•
The products shown herein are not designed and authorized for equipments requiring high
level of reliability or relating to human life and for any applications concerning life-saving
or life-sustaining, such as medical instruments, transportation equipment, aerospace
machinery et cetera. Customers using or selling the products for use in such applications
se
do so at their own risk and agree to fully indemnify Panjit International Inc. for any damages
resulting from such improper use or sale.
•
Since Panjit uses lot number as the tracking base, please provide the lot number for tracking
when complaining.
May 4,2015-REV.05
PAGE . 4