首页 > 器件类别 >

S8VS-12024BP

AC/DC Power Supply Single-OUT 24V 5A 120W 7-Pin

厂商名称:OMRON

厂商官网:https://www.omron.com

下载文档
S8VS-12024BP 在线购买

供应商:

器件:S8VS-12024BP

价格:-

最低购买:-

库存:点击查看

点击购买

文档预览
New Product
Switch Mode Power Supply
S8VS
(15/30/60/90/120/180/240/480-W Models)
Multi-Function Indication Monitor
for Production Site Visualization
*
• Status displayed on 3-digit, 7-segment display.
*
• Signal output notifications at 90 W or more.
*
• Conformity to various safety standards for global
usability.
• Varied coverage with 3-year warranty.
*
Models with indication monitor
!
Refer to
Safety Precautions for All Power Supplies
and
Safety
Precautions
on page 32.
Recommended Noise Filter
Noise filter
S8V-NF
For more information, refer to
S8V-NF Noise
Filter Data Sheet
(Cat. No. T212-E1).
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Model Number Structure
Model Number Legend
Note:
Not all combinations are possible. Refer to
List of Models
in
Ordering Information,
below.
S8VS-
@@@@@@@@-@
1
1. Power Ratings
015: 15 W
030: 30 W
060: 60 W
090: 90 W
120: 120 W
180: 180 W
240: 240 W
480: 480 W
2. Output voltage
05: 5 V
12: 12 V
24: 24 V
2
3 4 5
6
5. UL Class 2 Output Standards (UL 1310)
None: Does not conform.
*
S:
Conforms.
*
15-W, 30-W, and 60-W models conform to Class 2
output standards (UL 1310).
Note:
The S option is available only for 90-W models.
6. Terminal Block Form
None: Screw terminal block
F:
Screwless terminal block
3. Indication monitor
None: Without indication monitor (standard model)
A:
With indication monitor (maintenance forecast
monitor)
B:
With indication monitor (total run time monitor)
BE: With indication monitor but without alarm output
(total run time monitor)
4. Alarm output
None: Sinking (Emitter COM)
*
P:
Sourcing (Collector COM)
Note:
No alarm output possible with 60-W models.
*
Both sinking and sourcing outputs are available for
480-W models.
Note:
Estimates can be provided for coatings and other specifications that are not given in the datasheet. Ask your OMRON representative for details.
1
S8VS
Ordering Information
List of Models
Note:
For details on normal stock models, contact your nearest OMRON representative.
Models without Indication Monitor (Standard Models)
Power ratings
Input voltage
Output voltage
5V
15 W
12 V
24 V
5V
30 W
60 W
90 W
120 W
180 W
240 W
480 W
100 to 240 VAC
24 V
100 to 240 VAC
(allowable range:
85 to 264 VAC or
80 to 370 VDC
*3)
12 V
24 V
Output current
2.0 A
1.2 A
0.65 A
4.0 A
2.5 A
1.3 A
2.5 A
3.75 A
5A
7.5 A
10 A
20 A
Peak current 30 A
(200 VAC)
UL Class 2
Output standards
Yes
Yes
Yes
Yes
Yes
Yes
Yes
---
Yes
---
---
---
---
Model number
(screw terminal block)
S8VS-01505
*1
S8VS-01512
S8VS-01524
S8VS-03005
*2
S8VS-03012
S8VS-03024
S8VS-06024
S8VS-09024
S8VS-09024S
S8VS-12024
S8VS-18024
S8VS-24024
S8VS-48024
S8VS-06024-F
S8VS-09024-F
S8VS-09024S-F
S8VS-12024-F
S8VS-18024-F
S8VS-24024-F
S8VS-48024-F
---
Model number
(screwless terminal block)
*1.
The output capacity of the S8VS-01505 is 10 W.
*2.
The output capacity of the S8VS-03005 is 20 W.
*3.
The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
Models with Indication Monitor (Maintenance Forecast Monitor)
Power ratings
60 W
Input voltage
Output
voltage
Output current
2.5 A
Alarm
output
*2
---
Sinking
90 W
100 to 240
VAC
(allowable
range: 85 to
264 VAC or 80
to 370 VDC
*1)
3.75 A
Sinking
Sourcing
Sourcing
24 V
5A
7.5 A
10 A
100 to 240
VAC
20 A
Peak current 30 A
(200 VAC)
Sinking
Sourcing
Sinking
Sourcing
Sinking
Sourcing
Sinking/
sourcing
UL Class 2
Output standards
Yes
---
Yes
---
Yes
---
---
---
---
---
---
---
Model number
(screw terminal block)
S8VS-06024A
S8VS-09024A
S8VS-09024AS
S8VS-09024AP
S8VS-09024APS
S8VS-12024A
S8VS-12024AP
S8VS-18024A
S8VS-18024AP
S8VS-24024A
S8VS-24024AP
S8VS-48024A
Model number
(screwless terminal block)
S8VS-06024A-F
S8VS-09024A-F
S8VS-09024AS-F
S8VS-09024AP-F
S8VS-09024APS-F
S8VS-12024A-F
S8VS-12024AP-F
S8VS-18024A-F
S8VS-18024AP-F
S8VS-24024A-F
S8VS-24024AP-F
S8VS-48024A-F
120 W
180 W
240 W
480 W
*1.
The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
*2.
In the
Alarm output
column, “sinking” indicates an emitter COM and “sourcing” indicates a collector COM.
Models with Indication Monitor (Total Run Time Monitor)
Power ratings
60 W
Input voltage
Output
voltage
Output current
2.5 A
Alarm
output
*2
---
---
---
90 W
100 to 240
VAC
(allowable
range: 85 to
264 VAC or 80
to 370 VDC)
*1
3.75 A
Sinking
Sinking
Sourcing
Sourcing
---
24 V
5A
Sinking
Sourcing
---
7.5 A
Sinking
Sourcing
---
240 W
10 A
20 A
Peak current 30 A
(200 VAC)
Sinking
Sourcing
480 W
100 to 240
VAC
Sinking/
sourcing
UL Class 2
Output standards
Yes
---
Yes
---
Yes
---
Yes
---
---
---
---
---
---
---
---
---
---
Model number
(screw terminal block)
S8VS-06024B
S8VS-09024BE
S8VS-09024BES
S8VS-09024B
S8VS-09024BS
S8VS-09024BP
S8VS-09024BPS
S8VS-12024BE
S8VS-12024B
S8VS-12024BP
S8VS-18024BE
S8VS-18024B
S8VS-18024BP
S8VS-24024BE
S8VS-24024B
S8VS-24024BP
S8VS-48024B
Model number
(screwless terminal block)
S8VS-06024B-F
S8VS-09024BE-F
S8VS-09024BES-F
S8VS-09024B-F
S8VS-09024BS-F
S8VS-09024BP-F
S8VS-09024BPS-F
S8VS-12024BE-F
S8VS-12024B-F
S8VS-12024BP-F
S8VS-18024BE-F
S8VS-18024B-F
S8VS-18024BP-F
S8VS-24024BE-F
S8VS-24024B-F
S8VS-24024BP-F
S8VS-48024B-F
120 W
180 W
*1.
The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
*2.
In the
Alarm output
column, “sinking” indicates an emitter COM and “sourcing” indicates a collector COM.
Note:
Refer to pages 24 to 25 for the options that available.
2
S8VS
Specifications
Ratings/Characteristics
Power ratings
Item
Efficiency
Voltage
*1
Frequency
*1
Current
Input
Power factor
Harmonic current regulation
Leakage current
Inrush current
*2
With 100-VAC input
With 200-VAC input
With 100-VAC input
With 200-VAC input
With 100-VAC input
With 200-VAC input
Output voltage
With 100-VAC input
With 200-VAC input
5V
74% typical
73% typical
15 W
12 V
79% typical
78% typical
24 V
83% typical
80% typical
5V
74% typical
74% typical
30 W
12 V
81% typical
80% typical
24 V
85% typical
86% typical
100 to 240 VAC (allowable range: 85 to 264 VAC, 80 to 370 VDC
*5)
50/60 Hz (47 to 450 Hz)
0.45 A max., 0.34 A typical
0.25 A max., 0.22 A typical
---
Conforms to EN61000-3-2
0.5 mA max.
1.0 mA max.
17.5 A max., 14 A typical
35 A max., 28 A typical
−10%
to 15% (with V.ADJ)
60 mV max.
70 mV max.
60 mV max.
60 mV max.
90 mV max.
150 mV max.
0.5% max. (at 85- to 264-VAC input, 100% load)
2.0% max. (5 V), 1.5% max. (12 V, 24 V), (with rated input, 0 to 100% load)
0.05%/°C max.
580 ms typical
340 ms typical
39 ms typical
187 ms typical
Yes
*4
No
No
No
No
No
No
No
Yes (color: red)
No
No (However, backup operation is possible. An external diode is required.)
Models with 24-V output: Possible for up to 2 Power Supplies (with external diode)
Models with 5- or 12-V output: Not possible
Refer to the derating curve in
Engineering Data.
(with no icing or condensation)
−25
to 65°C
25% to 85% (Storage humidity: 25% to 90%)
3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA)
2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA)
1.0 kVAC for 1 min. (between all outputs and PE terminals; detection current: 20 mA)
100 MΩ min. (between all outputs and all inputs/ PE terminals) at 500 VDC
10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions
150 m/s
2
, 3 times each in ±X, ±Y, and ±Z directions
Yes (color: green)
Conducted
Emissions
Radiated Emissions
Conforms to EN55011 Group1 Class B and based on FCC Class A
Conforms to EN55011 Group1 Class B
Conforms to EN61204-3 high severity levels
UL 508 (Listing, Class2 Output: Per 1310)
UL 60950-1, UL 62368-1
CSA C22.2 No.107.1 (cUL) (Class2 Output: Per CSA C22.2 No.223)
CSA C22.2 No.60950-1 (cUR), No.62368-1
EN 50178, EN 60950-1, EN 62368-1
EAC mark, RCM mark
F47-0706 (With 200-VAC input)
160 g max.
180 g max.
530 ms typical
360 ms typical
27 ms typical
134 ms typical
600 ms typical
400 ms typical
28 ms typical
134 ms typical
500 ms typical
360 ms typical
31 ms typical
174 ms typical
560 ms typical
380 ms typical
22 ms typical
123 ms typical
560 ms typical
400 ms typical
31 ms typical
140 ms typical
0.9 A max., 0.66 A typical
0.6 A max., 0.4 A typical
Voltage adjustment range
*3
Ripple noise voltage (at rated I/O)
Input variation influence
Load variation influence
(rated input voltage)
Output
Temperature variation influence
Startup time
(at rated I/O)
*2
Output hold time
(at rated I/O)
*2
Overload protection
*2
Overvoltage protection
*2
Output voltage indication
Output current indication
Peak-hold current indication
Maintenance forecast monitor indication
Additional
functions
Maintenance forecast monitor output
Total run time monitor indication
Total run time monitor output
Undervoltage alarm indication
Undervoltage alarm output
Parallel operation
Series operation
Operating ambient temperature
Storage temperature
Operating ambient humidity
Dielectric strength
Insulation resistance
Vibration resistance
Shock resistance
Output indicator
Other
EMI
EMS
With 100-VAC input
With 200-VAC input
With 100-VAC input
With 200-VAC input
The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
Approved standards
SEMI
Weight
*1.
Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal
temperature of the Power Supply may result in ignition or burning.
*2.
For a cold start at 25°C. Refer to
Engineering Data
on page 18 for details.
*3.
If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than +15% of the voltage adjustment range. When adjusting
the output voltage, confirm the actual output voltage from the Power Supply and be sure that the load is not damaged.
*4.
To reset the protection, turn OFF the input power for three minutes or longer and then turn it back ON.
*5.
The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
3
S8VS
Power ratings
Item
Efficiency
Voltage
*1
Frequency
*1
Current
Input
Power factor
Harmonic current regulation
Leakage current
Inrush current
*2
With 100-VAC input
With 200-VAC input
With 100-VAC input
With 200-VAC input
With 100-VAC input
With 200-VAC input
Type
With 100-VAC input
With 200-VAC input
84% typical
83% typical
50/60 Hz (47 to 450 Hz)
1.7 A max., 1.3 A typical
1.0 A max., 0.68 A typical
---
Conforms to EN61000-3-2
0.5 mA max.
1.0 mA max.
17.5 A max., 14 A typical
35 A max., 28 A typical
Standard
83% typical
85% typical
60 W
Maintenance forecast monitor
Total run time monitor
100 to 240 VAC (allowable range: 85 to 264 VAC or 80 to 370 VDC
*11)
1.7 A max., 1.3 A typical
1.0 A max., 0.78 A typical
Voltage adjustment range
*3
Ripple noise voltage (at rated I/O)
Input variation influence
Load variation influence (rated input voltage)
Output
Temperature variation influence
Startup time
(at rated I/O)
*2
Output hold time
(at rated I/O)
*2
With 100-VAC input
With 200-VAC input
With 100-VAC input
With 200-VAC input
−10%
to 15% (with V. ADJ) (The voltage cannot be adjusted for the S8VS-09024@@@S-@.)
70 mV max.
1.5% max. (with rated input, 0 to 100% load)
0.05%/°C max.
620 ms typical
400 ms typical
34 ms typical
158 ms typical
Yes
No
No
No
No
No
No
No
No
No
No (However, backup operation is possible. An external diode is required.)
Yes for up to 2 Power Supplies (with external diode)
Refer to the derating curve in . (with no icing or condensation)
−25
to 65°C
25% to 85% (Storage humidity: 25% to 90%)
3.0 kVAC for 1 min. (between all inputs and outputs/ alarm outputs; detection current: 20 mA)
2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA)
1.0 kVAC for 1 min. (between all outputs/ alarm outputs and PE terminals; detection current for standard models: 30 mA, detection
current for models with indication monitor: 20 mA)
500 VAC for 1 min. (between all outputs and alarm outputs; detection current: 20 mA)
100 MΩ min. (between all outputs/ alarm outputs and all inputs/ PE terminals) at 500 VDC
10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions
10 to 150 Hz, 0.35-mm single amplitude (5 G max.) for 80 min each in X, Y, and Z directions
150 m/s
2
, 3 times each in ±X, ±Y, and ±Z directions
Yes (color: green)
Models with indication monitor: Conforms to EN55011 Group1 Class A and based on FCC Class A, Conforms to EN55011 Group1
Class B
*11
Standard models: Conforms to EN61204-3 EN55011 Group 1 Class B and based on FCC Class A
Models with indication monitor: Conforms to EN55011 Group1 Class A, Conforms to EN55011 Group1 Class B
*11
Standard models: Conforms to EN55011 Group1 Class B
Conforms to EN61204-3 high severity levels
UL 508 (Listing; Class 2 Output: Per UL1310)
UL 60950-1 (Recognition), UL 62368-1
CSA C22.2 No.107.1 (cUL) (Class 2 Output: Per CSA C22.2 No. 223)
CSA C22.2 No.60950-1 (cUR), No.62368-1
EN 50178, EN 60950-1, EN 62368-1
EAC mark, RCM mark
With indication monitor: UL 508 (Listing, Class2 Output: Per 1310)
CSA C22.2 No.107.1 (cUL) (Class2 Output: Per CSA C22.2 No.223)
EN 62477-1
EAC mark, RCM mark, KOSHA S Mark
*10
F47-0706 (With 200-VAC input)
330 g max.
Standard model:
Yes (selectable)
Yes (selectable)
Yes (selectable)
*6
Yes (selectable)
*7
Yes (selectable)
*8
Yes (selectable)
No
460 ms typical
290 ms typical
33 ms typical
154 ms typical
90 mV max.
0.5% max. (at 85- to 264-VAC input, 100% load)
Overload protection
*2
Overvoltage protection
*2, *4
Output voltage indication
*5
Output current indication
*5
Peak-hold current indication
*5
Additional
functions
Maintenance forecast monitor indication
*5
Maintenance forecast monitor output
Total run time monitor indication
*5
Total run time monitor output
*5
Undervoltage alarm indication
*5
Undervoltage alarm output terminals
Parallel operation
Series operation
Operating ambient temperature
Storage temperature
Operating ambient humidity
105% to 160% of rated load current (101% to 110% of rated load current for the S8VS-09024@@@S-@), inverted L voltage drop, intermittent, automatic reset
Dielectric strength
Insulation resistance
Vibration resistance
Shock resistance
Output indicator
Other
Conducted
Emissions
Radiated
Emissions
EMS
EMI
Approved standards
*11
SEMI
*11
Weight
*1.
Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in
ignition or burning.
*2.
For a cold start at 25°C. Refer to
Engineering Data
on page 18 for details.
*3.
If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than +15% of the voltage adjustment range (by more than +10% for 240-W models with indication monitor).
When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that the load is not damaged.
*4.
To reset the protection, turn OFF the input power for three minutes or longer and then turn it back ON.
*5.
Displayed on 7-segment LED. (character height: 8 mm)
*6.
Resolution of output voltage indication: 0.1 V, Precision of output voltage indication:
±2%
(percentage of output voltage value,
±1
digit)
*7.
Resolution of output current indication: 0.1 A; Precision of output current indication:
±5%
F.S.
±1
digit max. (specified by rated output voltage)
*8.
Resolution of peak-hold current indication: 0.1 A; Precision of peak-hold current indication:
±5%
F.S.
±1
digit max. (specified by rated output voltage);
Signal width required for peak-hold current: 20 ms
*9.
A Type and B Type: Sinking, AP Type and BP Type: Sourcing, BE Type: No alarm output.
*10.
S8VS-06024A, S8VS-09024A/AP, S8VS-12024A/AP, S8VS-18024A/AP, and S8VS-24024A/AP only
*11.
The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
4
S8VS
Power ratings
Item
Efficiency
Voltage
*1
Frequency
*1
Current
Input
Power factor
Harmonic current regulation
Leakage current
Inrush current
*2
With 100-VAC input
With 200-VAC input
With 100-VAC input
With 200-VAC input
With 100-VAC input
With 200-VAC input
Type
With 100-VAC input
With 200-VAC input
83% typical
84% typical
50/60 Hz (47 to 450 Hz)
2.3 A max., 1.9 A typical
1.4 A max., 1.0 A typical
---
Conforms to EN61000-3-2
0.5 mA max.
1.0 mA max.
17.5 A max., 14 A typical
35 A max., 28 A typical
Standard
83% typical
85% typical
90 W
Maintenance forecast monitor
Total run time monitor
100 to 240 VAC (allowable range: 85 to 264 VAC or 80 to 370 VDC
*11)
2.3 A max., 1.9 A typical
1.4 A max., 1.2 A typical
Voltage adjustment range
*3
Ripple noise voltage (at rated I/O)
Input variation influence
Load variation influence (rated input voltage)
Output
Temperature variation influence
Startup time
(at rated I/O)
*2
Output hold time
(at rated I/O)
*2
With 100-VAC input
With 200-VAC input
With 100-VAC input
With 200-VAC input
−10%
to 15% (with V. ADJ) (The voltage cannot be adjusted for the S8VS-09024@@@S-@.)
250 mV max.
1.5% max. (with rated input, 0 to 100% load)
0.05%/°C max.
460 ms typical
300 ms typical
28 ms typical
132 ms typical
Yes
No
No
No
No
No
No
No
No
No
Yes (selectable)
Yes (transistor output), 30 VDC max., 50 mA max.
*9
Yes (selectable)
*6
Yes (selectable)
*7
Yes (selectable)
*8
Yes (selectable)
No
Yes (selectable)
Yes (transistor output), 30 VDC max., 50 mA max.
*9
Yes (transistor output), 30 VDC max., 50 mA max.
*9
No
660 ms typical
420 ms typical
28 ms typical
136 ms typical
150 mV max.
0.5% max. (at 85- to 264-VAC input, 100% load)
Overload protection
*2
Overvoltage protection
*2, *4
Output voltage indication
*5
Output current indication
*5
Peak-hold current indication
*5
Additional
functions
Maintenance forecast monitor indication
*5
Maintenance forecast monitor output
Total run time monitor indication
*5
Total run time monitor output
*5
Undervoltage alarm indication
*5
Undervoltage alarm output terminals
Parallel operation
Series operation
Operating ambient temperature
Storage temperature
Operating ambient humidity
105% to 160% of rated load current (101% to 110% of rated load current for the S8VS-09024@@@S-@), inverted L voltage drop, intermittent, automatic reset
No (However, backup operation is possible. An external diode is required.)
Yes for up to 2 Power Supplies (with external diode)
Refer to the derating curve in . (with no icing or condensation)
−25
to 65°C
25% to 85% (Storage humidity: 25% to 90%)
3.0 kVAC for 1 min. (between all inputs and outputs/ alarm outputs; detection current: 20 mA)
2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA)
1.0 kVAC for 1 min. (between all outputs/ alarm outputs and PE terminals; detection current for standard models: 30 mA, detection
current for models with indication monitor: 20 mA)
500 VAC for 1 min. (between all outputs and alarm outputs; detection current: 20 mA)
100 MΩ min. (between all outputs/ alarm outputs and all inputs/ PE terminals) at 500 VDC
10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions
10 to 150 Hz, 0.35-mm single amplitude (5 G max.) for 80 min each in X, Y, and Z directions
150 m/s
2
, 3 times each in ±X, ±Y, and ±Z directions
Yes (color: green)
Conducted
Emissions
Radiated
Emissions
Models with indication monitor: Conforms to EN55011 Group1 Class A and based on FCC Class A, Conforms to EN55011 Group1
Class B
*11
Standard models: Conforms to EN61204-3 EN55011 Group 1 Class B and based on FCC Class A
Models with indication monitor: Conforms to EN55011 Group1 Class A, Conforms to EN55011 Group1 Class B
*11
Standard models: Conforms to EN55011 Group1 Class B
Conforms to EN61204-3 high severity levels
UL 508 (Listing)
(S8VS-09024S-@ only): UL 508 (Listing, Class2 Output: Per 1310)
UL 60950-1 (Recognition), UL 62368-1
CSA C22.2 No.107.1 (cUL)
(S8VS-09024S-@ only): CSA C22.2 No.107.1 (cUL) (Class2 Output: Per CSA C22.2 No.223)
CSA C22.2 No.60950-1 (cUR), No.62368-1
EN 50178, EN 60950-1, EN 62368-1
EAC mark, RCM mark
With indication monitor: UL 508 (Listing)
(S8VS-09024@@S-@ only): UL 508 (Listing, Class2 Output: Per 1310)
CSA C22.2 No.107.1
(S8VS-09024@@S-@ only): CSA C22.2 No.107.1 (cUL) (Class2 Output: Per CSA C22.2 No.223)
EN 62477-1
EAC mark, RCM mark, KOSHA S Mark
*10
F47-0706 (With 200-VAC input)
490 g max.
Standard model:
Dielectric strength
Insulation resistance
Vibration resistance
Shock resistance
Output indicator
Other
EMI
EMS
Approved standards
*11
SEMI
*11
Weight
*1.
Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in
ignition or burning.
*2.
For a cold start at 25°C. Refer to
Engineering Data
on page 18 for details.
*3.
If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than +15% of the voltage adjustment range (by more than +10% for 240-W models with indication monitor).
When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that the load is not damaged.
*4.
To reset the protection, turn OFF the input power for three minutes or longer and then turn it back ON.
*5.
Displayed on 7-segment LED. (character height: 8 mm)
*6.
Resolution of output voltage indication: 0.1 V, Precision of output voltage indication:
±2%
(percentage of output voltage value,
±1
digit)
*7.
Resolution of output current indication: 0.1 A; Precision of output current indication:
±5%
F.S.
±1
digit max. (specified by rated output voltage)
*8.
Resolution of peak-hold current indication: 0.1 A; Precision of peak-hold current indication:
±5%
F.S.
±1
digit max. (specified by rated output voltage);
Signal width required for peak-hold current: 20 ms
*9.
A Type and B Type: Sinking, AP Type and BP Type: Sourcing, BE Type: No alarm output.
*10.
S8VS-06024A, S8VS-09024A/AP, S8VS-12024A/AP, S8VS-18024A/AP, and S8VS-24024A/AP only
*11.
The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
5
查看更多>
热门器件
热门资源推荐
器件捷径:
S0 S1 S2 S3 S4 S5 S6 S7 S8 S9 SA SB SC SD SE SF SG SH SI SJ SK SL SM SN SO SP SQ SR SS ST SU SV SW SX SY SZ T0 T1 T2 T3 T4 T5 T6 T7 T8 T9 TA TB TC TD TE TF TG TH TI TJ TK TL TM TN TO TP TQ TR TS TT TU TV TW TX TY TZ U0 U1 U2 U3 U4 U6 U7 U8 UA UB UC UD UE UF UG UH UI UJ UK UL UM UN UP UQ UR US UT UU UV UW UX UZ V0 V1 V2 V3 V4 V5 V6 V7 V8 V9 VA VB VC VD VE VF VG VH VI VJ VK VL VM VN VO VP VQ VR VS VT VU VV VW VX VY VZ W0 W1 W2 W3 W4 W5 W6 W7 W8 W9 WA WB WC WD WE WF WG WH WI WJ WK WL WM WN WO WP WR WS WT WU WV WW WY X0 X1 X2 X3 X4 X5 X7 X8 X9 XA XB XC XD XE XF XG XH XK XL XM XN XO XP XQ XR XS XT XU XV XW XX XY XZ Y0 Y1 Y2 Y4 Y5 Y6 Y9 YA YB YC YD YE YF YG YH YK YL YM YN YP YQ YR YS YT YX Z0 Z1 Z2 Z3 Z4 Z5 Z6 Z8 ZA ZB ZC ZD ZE ZF ZG ZH ZJ ZL ZM ZN ZP ZR ZS ZT ZU ZV ZW ZX ZY