PSBT20100UYT
ULTRA LOW VF SCHOTTKY BARRIER RECTIFIER
Voltage
Features
Ultra low forward voltage drop, low power loss
High efficiency operation
Lead free in compliance with EU RoHS 2011/65/EU directive
Green molding compound as per IEC61249 Std.. (Halogen Free)
100 V
Current
20 A
TO-220AB
Unit: inch(mm)
Mechanical Data
Case: Molded plastic, TO-220AB
Terminals: solder plated, solderable per MIL-STD-750,Method 2026
Approx. Weight: 0.067 ounces, 1.89 grams
Maximum Ratings And Electrical Characteristics
(T
A
=25 C unless otherwise noted)
PARAMETER
Maximum repetitive peak reverse voltage
Maximum rms voltage
Maximum dc blocking voltage
Maximum average forward rectified current
Peak forward surge current : 8.3ms single half sine-
wave superimposed on rated load
Typical thermal resistance (Note 1)
Operating junction temperature range
Storage temperature range
SYMBOL
V
RRM
V
RMS
V
R
I
F(AV)
I
FSM
R
θJC
T
J
T
STG
LIMIT
100
70
100
20
250
3
-55 to +150
-55 to +150
o
o
UNIT
V
V
V
A
A
C/W
o
o
C
C
Note : 1. Device mounted on a infinite heatsink , then measured the center of the marking side.
November 7,2016-REV.02
Page 1
PSBT20100UYT
Electrical Characteristics
(T
A
=25 C unless otherwise noted)
PARAMETER
Breakdown voltage
SYMBOL
V
BR
TEST CONDITION
I
R
=0.5mA
I
F
=5A
Instantaneous forward
voltage
I
F
=10A
V
F
I
F
=20A
I
F
=5A
I
F
=10A
V
R
=70V
Reverse current
I
R
V
R
=100V
T
J
=125 C
T
J
=25
o
C
T
J
=25 C
T
J
=125
o
C
o
o
o
MIN.
100
-
-
-
-
-
-
-
-
TYP.
-
0.48
0.57
-
0.41
0.53
5
-
12
MAX.
-
-
-
0.78
-
-
-
120
-
UNITS
V
V
T
J
=25 C
T
J
=25
o
C
o
V
A
A
mA
November 7,2016-REV.02
Page 2
PSBT20100UYT
TYPICAL CHARACTERISTIC CURVES
Fig.1 Forward Current Derating Curve
Fig.2 Typical Junction Capacitance
Fig.3 Typical Reverse Characteristics
Fig.4 Typical Forward Characteristics
Fig.5 Operating Temperature Derating Curve
November 7,2016-REV.02
Page 3
PSBT20100UYT
Part No Packing Code Version
Part No Packing Code
SBT20100UYT_T0_00001
Package Type
TO-220AB
Packing Type
50pcs / Tube
Marking
SBT20100UYT
Version
Halogen free
November 7,2016-REV.02
Page 4
PSBT20100UYT
Disclaimer
● Reproducing and modifying information of the document is prohibited without permission from Panjit
International Inc..
● Panjit International Inc. reserves the rights to make changes of the content herein the document anytime
without notification. Please refer to our website for the latest document.
● Panjit International Inc. disclaims any and all liability arising out of the application or use of any product
including damages incidentally and consequentially occurred.
● Panjit International Inc. does not assume any and all implied warranties, including warranties of fitness for
particular purpose, non-infringement and merchantability.
● Applications shown on the herein document are examples of standard use and operation. Customers are
responsible in comprehending the suitable use in particular applications. Panjit International Inc. makes no
representation or warranty that such applications will be suitable for the specified use without further testing or
modification.
● The products shown herein are not designed and authorized for equipments requiring high level of reliability or
relating to human life and for any applications concerning life-saving or life-sustaining, such as medical
instruments, transportation equipment, aerospace machinery et cetera. Customers using or selling these
products for use in such applications do so at their own risk and agree to fully indemnify Panjit International
Inc. for any damages resulting from such improper use or sale.
● Since Panjit uses lot number as the tracking base, please provide the lot number for tracking when
complaining.
November 7,2016-REV.02
Page 5