POWR-GARD
®
Fuse Datasheet
CBO, CCK, CCL SERIES LIFT TRUCK FUSES
32-125 Vdc • 1-300 A • Fast Acting & Time Delay
Specifications
Voltage Ratings:
CBO: 32 Volts DC
CCK: 125 Volts DC (1-300A)
CCL: 125 Volts DC
Ampere Range:
1 – 300 amperes
Interrupting Rating:
10,000 A
For operating characteristics contact factory
Ordering Information
Description
CBO fast acting, and CCK and CCL dual-element time-delay fuses
are recommended for fork lift trucks and other similar battery
operated equipment.
—
12
—
20
AMPERE RATINGS
CBO FAST ACTING (32 Vdc)
—
30
35
40
50
60
70
75
80
100
125
150
Applications
Lift trucks, scissor lifts, pallet movers, and other low
voltage battery operated equipment used to move
hazardous materials.
1
2
10
15
AMPERE RATINGS
CCK TIME-DELAY (125 Vdc)
20
25
30
35
40
50
60
70
75
80
100
120
140
150
160
175
200
225
250
300
Dimensions (inches)
PART NO.
CCK 1-30A
CCK 35-60A
CCK 70-100A
CCK 120-200A
CCK 225-300A
CCL 30-60A
CCL 80-120A
A
3.070
3.740
4.460
4.720
4.710
3.07
3.49
B
2.500
3.000
3.500
3.750
3.750
2.5
2.75
1.625"
0.812"
0.343"
1.00"
C
0.56
0.81
1.06
1.06
1.06
0.56
0.81
AMPERE RATINGS
CCL TIME-DELAY (125 Vdc)
30
35
40
50
60
80
100
120
—
—
SERIES
CBO
CCK
CCL
TYPE
FAST ACTING
TIME-DELAY
TIME-DELAY
VOLT
DC
32
125
125
AMP
10
120
120
CATALOG
NUMBER
CBO010
CCK120
CCL120
ORDERING
NUMBER
0CBO010.V
0CCK120.V
0CCL120.V
A
B
C
2.43"
3.18"
CCK/CCL
CBO
littelfuse.com
1 of 1
© 2017 Littelfuse POWR-GARD
®
Products
Rev: 101317