POWR-GARD
®
Fuse Datasheet
SPF SerieS Solar FUSeS
1000 VDC • 1-30 A
Specifications
Voltage Rating
Amperage Rating
Max. Interrupting Rating
Time Constant
Material
Approvals
1000 VDC
1, 2, 3, 3.5, 4, 5, 6, 8, 10, 12, 15, 20, 25, 30
20 kA
≤
2ms
Body: Melamine
Caps: Copper Alloy
UL 2579 Listed (File: E339112)
IEC 60269-6 (1-25 A)
VDE Certified (No. 40033098)*
see specifications on pg. 2
CSA Certified (File: 029862_0_000)
RoHS Compliant
Mexico
Environmental
Country of Origin
Description
The SPF Solar Protection Fuse series has been specifically
designed for the protection of photovoltaic (PV) systems.
This family of Midget style fuses (10 x 38 mm) can safely
protect PV modules and conductors from reverse-
overcurrent conditions.
As PV systems have grown in size, so have the
corresponding voltage requirements. This increase in system
voltage has typically been intended to minimize power
loss associated with long conductor runs. Standard circuit
protection devices are not designed to completely protect
photovoltaic panels. However, the SPF series is UL Listed to
safely interrupt faulted circuits up to this demanding voltage
level.
Littelfuse offers 14 ampere ratings to match specific
requirements in a variety of applications.
Part Numbering System
0SPF xxxx H XR
Series
Amp Code
Refer to Amp Code
Column in Electrical
Specifications Table
Package
QUantity
10
10
100
moUnting
method
FeRRuLe
FeRRuLe
PCB TABS
Mounting Options
Blank = Ferrule
XR = PCB
Package Quantity
T = 10
H = 100
SerieS amP
SPF
SPF
SPF
2
3.5
30
catalog
nUmber
SPF002
SPF03.5
SPF030R
ordering
nUmber
0SPF002.T
0SPF03.5T
0SPF030.HXR
Features/Benefits
•
•
•
•
•
Meets UL, IEC and VDE photovoltaic standards
UL 2579 Listed 1000 VDC maximum
1-30 A ratings available
20,000 A Interrupting Rating
Both PCB mount and dead-front holder options available
Dimensions Inches (mm)
Ferrule Version
PCB Version
.06 (1.52)
.02 (.51)
.14
(3.56)
.04
(1.02)
Applications
• Inverters
• Combiner boxes
• Battery charge controllers
1.5 (38.1)
1.53
(38.86)
Recommended Fuse Holders
LPHV 1000 VDC POWR-Safe Series
Web Resources
Downloadable CAD drawings and other technical
information:
Littelfuse.com/spf
.406
(10.31)
.50 (12.7)
.12 (3.05)
MOUNTING HOLE
DETAIL
.12 .28
(3.05) (7.11)
.406 (10.31)
look for this logo to indicate products that are used in solar applications. Visit our website
Littelfuse.com/solar
for the latest updates on approvals, certifications, and new products.
Littelfuse.com
1 of 4
© 2013 Littelfuse POWR-GARD
®
Products
Rev:4-D-052413
POWR-GARD
®
Fuse Datasheet
SPF SerieS Solar FUSeS
Electrical Specifications
Ferrule Version
amPerage
Voltage interrUPting
rating
dc
001.
002.
003.
03.5
004.
005.
006.
008.
010.
012.
015.
020.
025.
030.
0SPF001.T
0SPF002.T
0SPF003.T
0SPF03.5T
0SPF004.T
0SPF005.T
0SPF006.T
0SPF008.T
0SPF010.T
0SPF012.T
0SPF015.T
0SPF020.T
0SPF025.T
0SPF030.T
07945816907
07945816910
07945816913
07945880087
07945816916
07945816919
07945816922
07945816925
07945816928
07945816931
07945816934
07945816937
07945817595
07945817598
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
ac
–
–
–
–
–
–
–
–
–
–
–
–
–
–
dc
20 kA
20 kA
20 kA
20 kA
20 kA
20 kA
20 kA
20 kA
20 kA
20 kA
20 kA
20 kA
20 kA
20 kA
agency
aPProValS
Ul Vde cSa
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
amP ordering
code nUmber
UPc
nom cold
reSiStance
(ohm)
0.394
0.237
0.11
0.07787
0.06127
0.04086
0.0281
0.0178
0.0125
0.00993
0.00799
0.0045
0.00353
0.00284
WattS loSS
WattS loSS
at 100% rated at 80% rated
cUrrent (W) cUrrent (W)
0.602
1.586
1.504
1.365
1.491
1.465
1.348
1.610
1.760
1.965
2.282
2.810
2.981
3.923
0.410
0.851
0.824
0.778
0.839
0.859
0.769
0.914
1.000
1.109
1.382
1.574
1.745
2.125
total
clearing i
2
t
(a
2
s) 10 ka
0.554
1.175
5.007
11.297
23.031
42.600
76.270
193.323
395.556
599.198
457.740
1173.990
1937.430
2209.480
total
clearing i
2
t
(a
2
s) 20 ka
0.554
4.755
7.882
11.297
23.031
42.600
80.254
198.960
401.208
641.940
504.770
1312.850
2371.140
2678.750
1
2
3
3.5
4
5
6
8
10
12
15
20
25
30
Electrical Specifications
PCB Version
amPerage
amP
code
Voltage interrUPting
rating
dc
001. 0SPF001.HXR 07945816909
002. 0SPF002.HXR 07945816912
003. 0SPF003.HXR 07945816915
03.5 0SPF03.5HXR 07945880089
004. 0SPF004.HXR 07945816918
005. 0SPF005.HXR 07945816921
006. 0SPF006.HXR 07945816924
008. 0SPF008.HXR 07945816927
010.
012.
015.
0SPF010.HXR 07945816930
0SPF012.HXR 07945816933
0SPF015.HXR 07945816936
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
ac
–
–
–
–
–
–
–
–
–
–
–
–
–
–
dc
20 kA
20 kA
20 kA
20kA
20 kA
20 kA
20 kA
20 kA
20 kA
20 kA
20 kA
20 kA
20 kA
20 kA
agency
aPProValS
Ul
•
•
•
•
•
•
•
•
•
•
•
•
•
•
cSa
•
•
•
•
•
•
•
•
•
•
•
•
•
•
ordering
nUmber
UPc
nom cold
reSiStance
(ohm)
0.394
0.237
0.11
0.07787
0.06127
0.04086
0.0281
0.0178
0.0125
0.00993
0.00799
0.0045
0.00353
0.00284
WattS loSS
at 100% rated
cUrrent (W)
0.602
1.586
1.504
1.365
1.491
1.465
1.348
1.610
1.760
1.965
2.282
2.810
2.981
3.923
WattS loSS
at 80% rated
cUrrent (W)
0.410
0.851
0.824
0.778
0.839
0.859
0.769
0.914
1.000
1.109
1.382
1.574
1.745
2.125
total
clearing i
2
t
(a
2
s) 10 ka
0.554
1.175
5.007
11.297
23.031
42.600
76.270
193.323
395.556
599.198
457.740
1173.990
1937.430
2209.480
total
clearing i
2
t
(a
2
s) 20 ka
0.554
4.755
7.882
11.297
23.031
42.600
80.254
198.960
401.208
641.940
504.770
1312.850
2371.140
2678.750
1
2
3
3.5
4
5
6
8
10
12
15
20
25
30
020. 0SPF020.HXR 07945817594
025. 0SPF025.HXR 07945817597
030. 0SPF030.HXR 07945817600
Littelfuse.com
2 of 4
© 2013 Littelfuse POWR-GARD
®
Products
Rev:4-D-052413
POWR-GARD
®
Fuse Datasheet
SPF SerieS Solar FUSeS
Electrical Specification – Agency Requirements
amPerage
rating
1-30
oPening time (minUteS)
100% of amp
rating per Ul
Temperature
Stabilization
113% of amp
rating per iec
60 Min
135% of amp
rating per Ul
60 Max
145% of amp
rating per iec
60 Max
200% of amp
rating per Ul
4 Max
Temperature Derating Curve (Temperature of Air Immediately Surrounding Fuse)
PERCENT OF UPRATING
60
40
20
0
0
PERCENT OF DOWNRATING
20
40
60
-60°C
-76°F
-40°C
-40°F
-20°C
-4°F
0°C
32°F
20°C
40°C
60°C
68°F
104°F
140°F
AMBIENT TEMPERATURE
80°C
176°F
100°C
212°F
120°C
248°F
140°C
284°F
Recommended Process Parameters
WaVe Parameter
PReHeAT:
TeMPeRATuRe MInIMuM:
TeMPeRATuRe MAXIMuM:
PRe-HeAT TIMe
SOLDeR POT TeMPeRATuRe
SOLDeR DWeLL TIMe
COMPLeTe CYCLe TIMe
lead Free recommendation
(Typical Industry Recommendation)
Soldering Parameters
130˚ C
—
75 Seconds Maximum
280˚ C Maximum
270˚ C for 8 Seconds Maximum
250 Seconds Maximum
Littelfuse.com
3 of 4
© 2013 Littelfuse POWR-GARD
®
Products
Rev:4-D-052413
POWR-GARD
®
Fuse Datasheet
SPF SerieS Solar FUSeS
Time Current Curve (1-12 A)
1000
900
800
700
600
500
100
90
80
70
60
50
200
300
400
0.1
0.2
0.3
0.4
1
0.9
0.8
0.7
0.6
0.5
10
9
8
7
6
5
20
30
40
2
3
4
1000
900
800
700
600
500
400
300
200
1000
900
800
700
600
500
400
- 1A
- 2A
- 3A
- 3.5A
- 4A
- 5A
- 6A
- 8A
- 10A
- 12A
300
200
100
90
80
70
60
50
40
30
20
100
90
80
70
60
50
40
30
20
10
9
8
7
6
5
10
9
8
7
6
5
4
3
2
TIME IN SECONDS
4
3
2
1
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
1
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0.09
0.08
0.07
0.06
0.05
0.04
0.03
0.02
0.1
0.09
0.08
0.07
0.06
0.05
0.04
0.03
0.02
0.01
1000
900
800
700
600
500
100
90
80
70
60
50
200
300
400
0.1
0.2
0.3
0.4
1
0.9
0.8
0.7
0.6
0.5
10
9
8
7
6
5
20
30
40
2
3
4
0.01
CURRENT IN AMPERES
Time Current Curve (15-30 A)
0.1
1000
900
800
700
600
500
400
300
200
100
90
80
70
60
50
40
30
20
10
9
8
7
6
5
4
3
2
TEST VOLTAGE:
BASIS FOR DATA:
1000V
TIME CONSTANT/POWER FACTOR:
FUSE CATALOG NUMBER:
SPF 1A - 30A
LITTELFUSE, INC.
CHICAGO, IL. USA
2
3
DRAWN BY:
LLL
DATE:
3/15/10
REVISION:
D
1000
900
800
700
600
500
400
100
90
80
70
60
50
40
200
300
TIME CURRENT CHARACTERISTIC CURVES
- THIS DATA GENERATED IN EXCEL -
0.2
0.3
1
0.9
0.8
0.7
0.6
0.5
0.4
10
9
8
7
6
5
4
20
30
DRAWING NO.:
FCC01-SPF
SHEET 2 OF 3
1000
900
800
700
600
500
400
300
200
100
90
80
70
60
50
40
30
20
- 15A
- 20A
- 25A
- 30A
TIME IN SECONDS
10
9
8
7
6
5
4
3
2
1
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
1
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0.09
0.08
0.07
0.06
0.05
0.04
0.03
0.02
0.1
0.09
0.08
0.07
0.06
0.05
0.04
0.03
0.02
0.01
0.01
0.1
0.2
0.3
1
0.9
0.8
0.7
0.6
0.5
0.4
1000
900
800
700
600
500
400
100
90
80
70
60
50
40
200
300
10
9
8
7
6
5
4
20
30
2
3
CURRENT IN AMPERES
Littelfuse.com
TEST VOLTAGE:
BASIS FOR DATA:
1000V
TIME CONSTANT/POWER FACTOR:
4 of 4
FUSE CATALOG NUMBER:
SPF 1A - 30A
DRAWN BY:
LLL
DATE:
3/15/10
© 2013 Littelfuse POWR-GARD
®
Products
Rev:4-D-052413
LITTELFUSE, INC.