https://www.phoenixcontact.com/pi/products/1407310
Sensor/actuator cable - SAC-3P-MS/ 5,0-28R/FS SCO RAIL - 1407310
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Sensor/actuator cable, 3-position, PE-X halogen-free, black, shielded, Plug straight M12 SPEEDCON, A-
coded, on Socket straight M12 SPEEDCON, A-coded, cable length: 5 m, For railway applications
Why buy this product
Easy and safe: 100% electrically tested plug-in components
Safety thanks to flame retardancy: PA 6.6 grip and radiation-cross-linked cables satisfy the most stringent requirements
Securely locked by special vibration brake
Resistant to temperature influences – tested for an extended temperature range and for resistance to temperature shocks
Reliable signal transmission – 360° shielding in environments with electromagnetic interference
Key Commercial Data
Packing unit
GTIN
GTIN
4046356774260
1 pc
Technical data
Dimensions
Length of cable
5m
Ambient conditions
Ambient temperature (operation)
Degree of protection
-40 °C ... 85 °C (Plug / socket)
IP65
General
Note
Rated current at 40°C
Rated voltage
Number of positions
Further products with variable cable type and variable cable length can
be found in the accessories section
4A
250 V AC
250 V DC
3
09/30/2018 Page 1 / 5
https://www.phoenixcontact.com/pi/products/1407310
Sensor/actuator cable - SAC-3P-MS/ 5,0-28R/FS SCO RAIL - 1407310
Technical data
General
Color handle area
Insulation resistance
Coding
Standards/regulations
Status display
Protective circuit/component
Overvoltage category
Degree of pollution
Insertion/withdrawal cycles
Torque
black
≥ 100 MΩ
A - standard
M12 connector IEC 61076-2-101
Shock, vibration EN 50155
No
Unwired
II
3
≥ 100
0.4 Nm (M12 connector)
Material
Flammability rating according to UL 94
Contact material
Contact surface material
Contact carrier material
Material of grip body
Material, knurls
Sealing material
Standards/regulations
V0
CuSn
Ni/Au
PA 6.6
PA 6.6
Zinc die-cast, nickel-plated
NBR
PA 6.6: Fire protection in rail vehicles - requirement sets R22, R23, and
R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)
Standards and Regulations
Standard designation
Standards/regulations
Standard designation
Standards/regulations
Flammability rating according to UL 94
M12 connector
IEC 61076-2-101
Shock, vibration
EN 50155
V0
Cable
Cable type
Cable type (abbreviation)
Conductor cross section
AWG signal line
Conductor structure signal line
Core diameter including insulation
Wire colors
Overall twist
Shielding
External sheath, color
External cable diameter D
Shielded black RADOX
28R
3x 0.5 mm²
20
19x 0.18 mm
1.43 mm
White 1, white 2, white 3
3 wires, twisted
Tinned copper braided shield
black
5.3 mm ±0,3 mm
09/30/2018 Page 2 / 5
®
https://www.phoenixcontact.com/pi/products/1407310
Sensor/actuator cable - SAC-3P-MS/ 5,0-28R/FS SCO RAIL - 1407310
Technical data
Cable
Minimum bending radius, fixed installation
Minimum bending radius, flexible installation
Cable weight
Outer sheath, material
Material conductor insulation
Conductor material
Conductor resistance
Nominal voltage, cable
3xD
4xD
51 kg/km
PE-X
PE-X
Tin-plated Cu litz wires
≤ 40.1 Ω/km
600 V AC (Core-ground, U
0
)
1000 V AC (Core-ground, U)
≤ 720 V AC (core-ground)
≤ 1200 V AC (Core-ground, U
m
)
≤ 900 V DC (Core-ground, V
0
)
≤ 1500 V DC (core-core)
Test voltage, cable
Fire protection in rail vehicles
3500 V AC (50 Hz, 5 min.)
8400 V DC (50 Hz, 5 min.)
BS 6853 (Category Ia, Ib, II)
GM/RT 2130 (Category Ia, Ib, II)
EN 45545 (Risk level HL1 - HL3)
DIN 5510 (Fire protection level 1, 2, 3, 4)
NF F16-101 (Category A1, A2, B)
NF F16-101 (Class C/F0)
NFPA 130
UNI CEI 11170 (Risk level LR1 - LR4)
Flame resistance
EN 60332-1-2
EN 50266
EN 50305, 9.1.2
NF C32-070, 2.1
NF C32-070, 2.2
UL 1685, 12 (FT4)
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Halogen-free
Resistance to oil
Other resistance
Concentration of fumes
According to EN 50267-2-1
according to IRM 902, 72 h at 100 °C
Resistance to fuels according to IRM 903, 168 h at 70 °C
BS 6853 D.8.7
EN 61034-2
UL 1685, 12 (FT4)
Fume corrosiveness
Fume toxicity
Ambient temperature (operation)
EN 50267-2-2
BS 6853 B.1
EN 50305, 9.2
-50 °C ... 120 °C (cable, fixed installation)
09/30/2018 Page 3 / 5
https://www.phoenixcontact.com/pi/products/1407310
Sensor/actuator cable - SAC-3P-MS/ 5,0-28R/FS SCO RAIL - 1407310
Technical data
Cable
-25 °C ... 90 °C (cable, flexible installation)
Environmental Product Compliance
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values
Drawings
Schematic diagram
4
3
Schematic diagram
3
4
1
1
Pin assignment M12 plug, 3-pos., A-coded, view male side
Pin assignment M12 socket, 3-pos., A-coded, view female side
Cable cross section
Dimensional drawing
46,8
Ø14,8
Shielded black RADOX [28R]
M12 SPEEDCON plug, straight, shielded
®
Dimensional drawing
Circuit diagram
44
1
1
4
3
Ø14,8
4
3
Socket M12-SPEEDCON, straight, shielded
M12
Ø16
Contact assignment of M8 plugs / M12 sockets
Ø16
09/30/2018 Page 4 / 5
https://www.phoenixcontact.com/pi/products/1407310
Phoenix Contact 2018 © - all rights reserved
http://www.phoenixcontact.com
PHOENIX CONTACT GmbH & Co. KG
Flachsmarktstr. 8
32825 Blomberg
Germany
Tel. +49 5235 300
Fax +49 5235 3 41200
http://www.phoenixcontact.com