首页 > 器件类别 > 电路保护 > 电路保护

1DR8

Circuit Breakers 8A MCB DCHAR 1pl 277VAC UL508

器件类别:电路保护    电路保护   

厂商名称:Altech

厂商官网:http://www.altechcorp.com/

下载文档
1DR8 在线购买

供应商:

器件:1DR8

价格:-

最低购买:-

库存:点击查看

点击购买

器件参数
参数名称
属性值
厂商名称
Altech
Reach Compliance Code
unknown
电路保护类型
THERMAL MAGNETIC
文档预览
D-TRIP
CHARACTERISTICS
Application Examples:
ONE POLE
ONE POLE PLUS NEUTRAL
High inrush motors, transformers,
power supplies, heaters and reactive
loads. Relatively long thermal trip
delay and very high magnetic trip
point.
Prototype testing is recommended in
motor applications where the relatively
long thermal trip delay may not
provide adequate motor overload
protection. Motor-integral overload
protectors are recommended, with the
V-EA-D providing disconnect, backup
thermal protection and additional short
circuit and energy let-through
protection.
1D
Rated
Current
0.3A
0.5A
0.75A
0.8A
1.0A
1.6A
2.0A
2.5A
3.0A
3.5A
4.0A
5.0A
6.0A
8.0A
10A
12A
12.5A
13A
15A
16A
20A
25A
30A
32A
40A
50A
60A
63A
277VAC
0.3-60A (RC): 10kA with UL-listed
RK5 back-up fuse or MCCB
0.3-10A (RC): 10kA; 13-60A (RC): 5kA
no branch circuit protection required
0.3-63A (RC): 10kA
10000 ON/OFF operations
40°C (104°F)
10/0.3A - 32A = 1.4kg (3.1 lb.)
40A - 63A = 1.6kg (3.5 lb.)
Top: 18-3 AWG; Bottom: 18-2 AWG
20 lb.in.
Type/
Cat. No.
1DU03
1DU05
1DU075
NA
1DU1
1DU1.6
1DU2
1DU2.5
1DU3
1DU3.5
1DU4
1DU5
1DU6
1DU8
1DU10
NA
NA
1DU13
1DU15
1DU16
1DU20
1DU25
1DU30
1DU32
1DU40
1DU50
1DU60
1DU63
Approvals
UL
UL
UL
2DN
Type/
Cat. No.
2DNU03
2DNU05
2DNU075
NA
2DNU1
2DNU1.6
2DNU2
2DNU2.5
2DNU3
2DNU3.5
2DNU4
2DNU5
2DNU6
2DNU8
2DNU10
NA
NA
2DNU13
2DNU15
2DNU16
2DNU20
2DNU25
2DNU30
2DNU32
2DNU40
2DNU50
2DNU60
2DNU63
277VAC
0.3-60A (RC): 10kA with UL-listed
RK5 back-up fuse or MCCB
0.3-10A (RC): 10kA; 13-60A (RC): 5kA
no branch circuit protection required
0.3-63A (RC): 10kA
10000 ON/OFF operations
40°C (104°F)
5/0.3A - 32A = 1.3kg (2.9 lb.)
40A - 63A = 1.45kg (3.2 lb.)
Top: 18-3 AWG; Bottom: 18-2 AWG
20 lb.in.
Approvals
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
Type Designation
2
D
N
U
(a) (b) (c) (d)
60
(e)
(a)
= Number of Poles
(b)
= Trip Characteristic
(c)
= Blank: without neutral pole
= N:
with neutral pole
(d)
= U:
UL/CSA version
= R:
ring tongue terminals,
UL/CSA version
= Blank: European version
(e)
= Rated Current
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
Approvals:
*
*
*
*
*
*
*
*
UL508 Listed
Voltage Rating
Interrupting Capacity
(UL/CSA - Ratings)
Group Short Circuit
(UL/CSA - Ratings)
Interrupting Capacity (VDE - Ratings)
Mechanical Endurance
Calibration Temperature
Standard Pack and Weight
Terminal Size Acceptability
Terminal Torque
Basic Dimensions (Elevation View)
Not European standard rating.
Please refer to page 21 for specific
applications.
DC rating (Manufacturer’s self certification):
91.5 mm
(3.60 in.)
91.5 mm
(3.60 in.)
One pole 48VDC, two pole series 125VDC
* VDE pending
17.5 mm (0.69 in.)
35 mm (1.38 in.)
Altech Corp.
®
• 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com
12
TWO POLE
THREE POLE
Basic Dimensions (side view)
35 mm
(1.38 in.)
2D
Rated
Current
0.3A
0.5A
0.75A
0.8A
1.0A
1.6A
2.0A
2.5A
3.0A
3.5A
4.0A
5.0A
6.0A
8.0A
10A
12A
12.5A
13A
15A
16A
20A
25A
30A
32A
40A
50A
60A
63A
Type/
Cat. No.
2DU03
2DU05
2DU075
NA
2DU1
2DU1.6
2DU2
2DU2.5
2DU3
2DU3.5
2DU4
2DU5
2DU6
2DU8
2DU10
NA
NA
2DU13
2DU15
2DU16
2DU20
2DU25
2DU30
2DU32
2DU40
2DU50
2DU60
2DU63
Approvals
UL
UL
UL
3D
Type/
Cat. No.
3DU03
3DU05
3DU075
NA
3DU1
3DU1.6
3DU2
3DU2.5
3DU3
3DU3.5
3DU4
3DU5
3DU6
3DU8
3DU10
NA
NA
3DU13
3DU15
3DU16
3DU20
3DU25
3DU30
3DU32
3DU40
3DU50
3DU60
3DU63
480Y/277VAC
0.3-60A (RC): 10kA with UL-listed
RK5 back-up fuse or MCCB
0.3-10A (RC): 10kA; 13-60A (RC): 5kA
no branch circuit protection required
0.3-63A (RC): 10kA
10000 ON/OFF operations
40°C (104°F)
4/1.68kg (3.7 lb.)
Top: 18-3 AWG; Bottom: 18-2 AWG
20 lb.in.
Seconds
70mm (2.76 in.)
Approvals
UL
UL
UL
V-EA-D Trip
0.3A Through 10A Rated Current
1.13-1.45xI
N
60
40
Minutes
10
4
1
Thermal Overload
“Must Trip” < 1 hr = 145% RC
“Must Not Trip” > 1 hr = 113% RC
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
Tripping time t
UL
UL
UL
UL
UL
UL
UL
UL
UL
10
4
1
0.4
10
-1
4x10
-2
Seconds
10
-2
4x10
-3
10
-3
1
2
3 4 5 6 8
10 16
20
40
100
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
Multiple of Rated Current
V-EA-D Trip
13A Through 63A Rated Current
1.13-1.45xI
N
60
40
*
*
*
*
*
*
*
*
Minutes
10
4
1
Thermal Overload
“Must Trip” < 1 hr = 145% RC
“Must Not Trip” > 1 hr = 113% RC
480Y/277VAC
0.3-60A (RC): 10kA with UL-listed
RK5 back-up fuse or MCCB
0.3-10A (RC): 10kA; 13-60A (RC): 5kA
no branch circuit protection required
0.3-63A (RC): 10kA
10000 ON/OFF operations
40°C (104°F)
5/1.4kg (3.1 lb.)
Top: 18-3 AWG; Bottom: 18-2 AWG
20 lb.in.
Tripping time t
10
4
1
0.4
10
-1
4x10
-2
10
-2
4x10
-3
10
-3
1
2
3 4 5 6 8
10 16
20
40
100
Multiple of Rated Current
“D” Magnetic Trip Parameters
Rated current 0.3A to 63A.
1. Hold for a minimum of 100ms at
surge of 10 times rated current.
2. Trip in under 100ms at 16 times
rated current.
NB:
Trip curves shown comply with North
American standards. For trip curves
according to European standards please
consult Altech.
91.5 mm
(3.60 in.)
91.5 mm
(3.60 in.)
35 mm (1.38 in.)
52.5 mm (2.07 in.)
Altech Corp.
®
• 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com
13
查看更多>
热门器件
热门资源推荐
器件捷径:
A0 A1 A2 A3 A4 A5 A6 A7 A8 A9 AA AB AC AD AE AF AG AH AI AJ AK AL AM AN AO AP AQ AR AS AT AU AV AW AX AY AZ B0 B1 B2 B3 B4 B5 B6 B7 B8 B9 BA BB BC BD BE BF BG BH BI BJ BK BL BM BN BO BP BQ BR BS BT BU BV BW BX BY BZ C0 C1 C2 C3 C4 C5 C6 C7 C8 C9 CA CB CC CD CE CF CG CH CI CJ CK CL CM CN CO CP CQ CR CS CT CU CV CW CX CY CZ D0 D1 D2 D3 D4 D5 D6 D7 D8 D9 DA DB DC DD DE DF DG DH DI DJ DK DL DM DN DO DP DQ DR DS DT DU DV DW DX DZ
需要登录后才可以下载。
登录取消