Lead metallisation typically 100u inches Au over 50-250u inches Ni
-
-
-
-
ABSOLUTE MAXIMUM RATINGS
T
CASE
= 25°C unless otherwise stated
PD
VF
Tj
Tstg
R JA
P/N
Power Dissipation at TA = 25°C
Forward Voltage at 200mA
Operating Junction Temperature Range
Storage Temperature Range
Thermal Resistance Junction to Ambient
Nominal
Zener
Voltage
VZ @ IZT
V
Test
Current
IZT
mA
A&B
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
30
30
30
30
29
28
24
23
22
19
17
11
7.0
7.0
5.0
1200
1250
1300
1400
1600
1600
1700
1900
2000
1900
1600
1600
1600
1000
750
Maximum Zener Impedance
(1)
500mW
1.5V
-55°C to +175°C
-65°C to +175°C
300°C/W
Maximum Reverse
Leakage Current
IR
µA
100
100
75
75
50
25
15
10
5.0
5.0
5.0
5.0
5.0
5.0
3.0
A
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
1.9
1.9
2.9
3.3
3.8
4.8
@
V
B,C & D
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
2.0
2.0
3.0
3.5
4.0
5.0
VR
Maximum Zener
Voltage
(2)
Coefficient
VZ
%/°C
A&B
–0.085
–0.085
–0.080
–0.080
–0.075
–0.070
–0.065
–0.060
±0.055
±0.030
±0.030
+0.038
+0.038
+0.045
+0.050
ZZT @ IZK
ZZT @ IZK = 250µA
1N5221
1N5222
1N5223
1N5224
1N5225
1N5226
1N5227
1N5228
1N5229
1N5230
1N5231
1N5232
1N5233
1N5234
1N5235
2.4
2.5
2.7
2.8
3.0
3.3
3.6
3.9
4.3
4.7
5.1
5.6
6.0
6.2
6.8
Semelab Ltd reserves the right to change test conditions, parameter limits and package dimensions without notice. Information furnished by Semelab is believed
to be both accurate and reliable at the time of going to press. However Semelab assumes no responsibility for any errors or omissions discovered in its use.
Semelab encourages customers to verify that datasheets are current before placing orders.
Zener Impedance is measured to ensure a sharp knee characteristic on the breakdown curve. Derived from 50Hz ac voltage from ac current of 10% rms of IZT
(or IZK) superimposed on DC IZT (or IZK)
Temperature Coefficient test conditions:
a. IZT = 7.5mA , T1 = 25°C, T2 = 125°C (1N5221A, B through to 1N5242A, B)
b. I
= 7.5mA , T = 25°C, T = 125°C (1N5243A, B through to 1N5281A, B)
ZT
1
2
DUT temperature stabilised with constant current for VZ measurement @ T1,T2
2)
Semelab Ltd reserves the right to change test conditions, parameter limits and package dimensions without notice. Information furnished by Semelab is believed
to be both accurate and reliable at the time of going to press. However Semelab assumes no responsibility for any errors or omissions discovered in its use.
Semelab encourages customers to verify that datasheets are current before placing orders.