ATTENUATORS
SMA, Flange Mount, DC - 18 GHz, 2 Watts
SPECIFICATIONS:
Models: 2004, 2005, & 2006
Electrical:
Frequency Range
Standard dB Values*
Attenuation Accuracy
0 - 6 dB
7 - 20 dB
2 - 30 dB
1
VSWR
DC - 2 GHz
2 - 4 GHz
4 - 8 GHz
8 - 1 GHz
2.4
1
2.4 - 16 GHz
16 - 18 GHz
Input Power
Peak Power
Impedance
Operating Temp Range
DC - 18 GHz
0 - 10, 1 15, 20 & 30 dB
2,
In 1 dB Increments
±0.3 dB
±0.5 dB
±0.75 dB
1. 0:1 Max.
1
1. 5:1 Max.
1
1.20:1 Max.
1.25:1 Max.
1.30:1 Max.
1.35:1 Max.
2 Watts Avg. @ +25°C
Derated Linearly to 0.5 Watts @ +1
o
C
25
.50 [12.7]
SQ.
.340 [8.64]
TYP
.
250 Watts Max.
(5uSec Pulse, .05% Duty Cycle)
50 Ohms
-65°C to +125°C
Passivated Stainless Steel
Gold Plated Beryllium Copper
4-HOLE FLANGE
DETAIL - TYP
.
4X Ø.102 [2.59]
THRU
Mechanical:
SMA Connectors
Mates with MIL
-STD-348
Conductors
Model Number:
2004-XX
Male/Female Connector
DIM B: .665 ±.015 [16.89 ±0.38]
Length: 1. 2 ±.04 [28.4 ±1.0]
1
Pictured
.460
[11.68]
.200 [5.08]
.062 [1.57]
Ø.280 [7.11]
Model Number:
2005-XX
Male/Male Connector
DIM B: .665 ±.015 [16.89 ±0.38]
Length: 1.24 ±.04 [3 ±1.0]
1.5
Model Number:
2006-XX
Female/Female Connector
DIM B: .530 ±.010 [13.46 ±0.25]
Length: .99 ±.04 [25. ±1.0]
1
Ø.30 [7.62]
DIM B
1.12 ±.04
[28.4 ±1.0]
Ordering Examples:
2
Model Number:
2004-1
1 dB; SMA - Male/Female
2
HOW TO ORDER:
Model Number:
200X-YY
Base Number
4 = Male/Female
5 = Male/Male
6 = Female/Female
dB Value
Model Number:
2006-6
6 dB; SMA - Female/Female
Note: Dimensions in Brackets are Expressed in Millimeters and are for Reference Only.
2004: REV F
Aeroflex / Inmet, Inc.
300 Dino Drive, Ann Arbor, MI 48103 • U.S.A.
888-244-6638 or 734-426-5553 • FAX: 734-426-5557
www.aeroflex-inmet.com
• inmetsales@aeroflex.com