2035/2037 Series - Miniature 2-Pole Gas Discharge Tube
Characteristics
Test Methods per ITU-T (CCITT) K.12, IEEE C62.31
Model No.
2035-2037-09
2035/2037-15
2035/2037-20
2035/2037-23
2035/2037-25
2035/2037-30
Characteristic
DC Sparkover ±15 %
(±20 % for Model 2035/2037-09) @ 100 V/s
90 V
300 V
550 V
150 V
350 V
550 V
200 V
425 V
575 V
230 V
450 V
600 V
Model No.
250 V
475 V
625 V
300V
525 V
650 V
Impulse Sparkover
100 V/µs
1000 V/µs
Characteristic
DC Sparkover ±15 % @ 100 V/s
Impulse Sparkover
100 V/µs
1000 V/µs
2035/2037-35
2035/2037-40
2035/2037-42
2035/2037-47
2035/2037-60
350 V
600 V
750 V
400 V
650 V
800 V
420 V
675 V
850 V
470 V
750 V
950 V
600 V
950 V
1100 V
Insulation Resistance (IR) ..................100 V (50 V for Models 2035/2037-09) .................................. > 10
10
Ω
Glow Voltage ......................................10 mA ..................................................................................... ~ 70 V
Arc Voltage .........................................1 A .......................................................................................... ~ 10 V
Glow-Arc Transition Current ............................................................................................................... < 0.5 A
.......................135 V, (52 V for Models 2035/2037-09, .................................. < 150 ms
80 V for Models 2035/2037-15)
Impulse Discharge Current ................10000 A, 8/20 µs
2
................................................................... 1 operation min.
5000 A, 8/20 µs ...................................................................... > 10 operations
1000 A, 10/350 µs .................................................................. 1 operation
100 A, 10/1000 µs ................................................................. > 300 operations
100 A, 10/700 µs ................................................................... > 500 operations
Alternating Discharge Current ...........20 Arms, 11 cycles
2
................................................................ 1 operation min.
5 Arms, 1 s ............................................................................. > 10 operations
Operating Temperature ...................................................................................................................... -55 to +85 °C