INDUSTRIAL AUTOMATION
&
PROCESS
CONTROL
CABLES
15.82
CSA Control Cable
600V CIC Multi-conductor Cables
Description
Part
Number
No.
of
Cond.
Cable Weight
Lbs./
1000 Ft.
kg/km
Insulation Thickness
Inch
mm
Jacket Thickness
Inch
mm
Nominal OD
Inch
mm
14 AWG
Stranded (7x22) Bare Copper Conductors
Cross-linked Polyethylene Insulation • Black PVC Jacket
(Color Code: Black and Numbered)
CSA C22.2#239, Type CIC
CSA C22.2#0.3, Clause 4.31 Low Acid Test
FT4 Flame Test
22100
22101
22102
22103
22104
22105
22106
22107
22108
22110
-25°C Installed
-40°C to +105°C (Dry) (75°C Wet)
2
3
4
5
6
7
8
9
10
12
16
20
62
81
101
122
143
160
197
220
226
279
357
467
92
120
150
181
213
238
293
326
336
415
531
695
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.76
.76
.76
.76
.76
.76
.76
.76
.76
.76
.76
.76
.045
.045
.045
.045
.045
.045
.060
.060
.060
.060
.060
.080
1.14
1.14
1.14
1.14
1.14
1.14
1.52
1.52
1.52
1.52
1.52
2.03
.367
.388
.423
.462
.504
.504
.576
.618
.669
.689
.764
.886
9.32
9.86
10.74
11.73
12.80
12.80
14.63
15.70
17.00
17.50
19.41
22.50
22114
22118
12 AWG
Stranded (7x20) Bare Copper Conductors
Cross-linked Polyethylene Insulation • Black PVC Jacket
(Color Code: Black and Numbered)
CSA C22.2#239, Type CIC
CSA C22.2#0.3, Clause 4.31 Low Acid Test
FT4 Flame Test
22120
22121
22122
22123
22124
22125
22126
22127
22128
22130
-25°C Installed
-40°C to +105°C (Dry) (75°C Wet)
2
3
4
5
6
7
8
9
10
12
16
20
82
109
140
170
214
240
270
302
336
390
584
655
122
162
207
252
318
357
402
449
499
579
794
975
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.76
.76
.76
.76
.76
.76
.76
.76
.76
.76
.76
.76
.045
.045
.045
.045
.060
.060
.060
.060
.060
.060
.080
.080
1.14
1.14
1.14
1.14
1.52
1.52
1.52
1.52
1.52
1.52
2.03
2.03
.405
.429
.469
.515
.591
.591
.639
.687
.745
.768
.893
.992
10.29
10.90
11.91
13.08
15.01
15.01
16.23
17.45
18.92
19.51
22.68
25.20
22134
22138
10 AWG
Stranded (7x18) Bare Copper Conductors
Cross-linked Polyethylene Insulation • Black PVC Jacket
(Color Code: Black and Numbered)
CSA C22.2#239, Type CIC
CSA C22.2#0.3, Clause 4.31 Low Acid Test
FT4 Flame Test
22140
22141
22142
22143
22144
22145
22146
22147
22148
22150
-25°C Installed
-40°C to +105°C (Dry) (75°C Wet)
2
3
4
5
6
7
8
9
10
12
14
16
148
189
248
293
338
378
424
469
548
631
717
805
219
281
368
436
503
562
630
698
816
939
1067
1197
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.76
.76
.76
.76
.76
.76
.76
.76
.76
.76
.76
.76
.045
.045
.060
.060
.060
.060
.060
.060
.080
.080
.080
.080
1.14
1.14
1.52
1.52
1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
.736
.763
.839
.891
.944
.944
.999
1.074
1.182
1.209
1.255
1.307
18.69
19.38
21.31
22.63
23.98
23.98
25.37
29.28
30.02
30.71
31.88
33.20
22152
22154
B e l d e n E l e c t r o n i c s D i v i s i o n
Te c h n i c a l S u p p o r t :
1 - 8 0 0 - B E L D E N - 1
o r
1 - 8 0 0 - B E L D E N - 3
•
w w w . b e l d e n . c o m