23AT3-T2

Toggle Switches Toggle SW 4PDT 2POS Sold T 2 type Term

器件类别:机电产品    开关   

厂商名称:Honeywell

厂商官网:http://www.ssec.honeywell.com/

下载文档
23AT3-T2 在线购买

供应商:

器件:23AT3-T2

价格:-

最低购买:-

库存:点击查看

点击购买

器件参数
参数名称
属性值
Reach Compliance Code
unknown
ECCN代码
EAR99
执行器类型
STEEL LEVER
主体宽度
21.34 mm
主体高度
26.59 mm
主体长度或直径
33.32 mm
触点(交流)最大额定R负载
5A@250VAC
最大触点电流(交流)
5 A
最大触点电流(直流)
5 A
触点(直流)最大额定R负载
5A@30VDC
最大触点电压(交流)
250 V
最大触点电压(直流)
30 V
安装特点
PANEL MOUNT-THREADED
密封
CORROSION PROOF
表面贴装
NO
开关动作
LATCHED
开关功能
4PDT
开关类型
TOGGLE SWITCH
端接类型
WIRE
Base Number Matches
1
文档预览
Interactive Catalog Supplements Catalog PDFs
If you need detailed product information, or help choosing the right
product for your application, see our
Interactive Catalog.
Use the
Interactive Catalog
to access the most complete and up-to-date
information available.
The
Interactive Catalog
provides an extensive collection of product
specifications, application data, and technical literature that can be
searched based on criteria you select.
This PDF catalog information was published in November 2000.
Sensing and Control
Interactive
Catalog...
Click this icon to try
the Interactive Catalog.
Sensing and Control
Honeywell Inc.
11 West Spring Street
Freeport, IL 61032
www.honeywell.com/sensing
Manual Switches
Toggle Switch Assemblies
6AT SERIES
AT Series
FEATURES
2-position, momentary and
maintained action.
1, 2 or 3 SPDT precision basic
switches.
Short behind-panel depth.
Choice of
1
4
or
15
32
-inch bushings.
Silver or gold contacts.
UL recognized, CSA certified basic
switches.
ELECTRICAL RATINGS — Basic Switches
30 VDC Rating
Amps
UL/CSA Rating
Silver
Contacts
Gold
Contacts
5 amps,
125-250 VAC
1 amp,
125 VAC
Load
Inductive
Resistive
Max. Inrush
Inductive
Resistive
Max. Inrush
Sea Level
3
5
24
0.5
1
2
50,000 ft.
2.5
5
24
0.5
1
2
2-POSITION ORDER GUIDE
Toggle Lever Position
Mounting
Style
Bushing
With Key Tab
1
4
Keyway
Maint.
Opposite
Keyway
Maint.
Number
of
Poles
1
Types
Contacts
Silver
Gold
Solder
Terminals
6AT2
6AT23
6AT3
6AT501
6AT1
‘‘T’’
Terminals
6AT2-T
6AT68-T*
6AT3-T
6AT13-T
6AT501-T
6AT1-T
‘‘T2’’
Terminals
6AT2-T2
6AT68-T2*
6AT23-T2
6AT3-T2
6AT13-T2
6AT1-T2
6AT56-T2
2
3
Bushing
Without Key Tab
1
4
Silver
Gold
Silver
Silver
Gold
Maint.
Maint.
1
2
Bushing
With Key Washer
Bushing
With Key Washer
15
32
1
4
Silver
Silver
Gold
Silver
Gold
Silver
Gold
Silver
Gold
6AT4
6AT201-T
6AT4-T2
6AT231-T2
Maint.
Maint.
Maint.
Maint.
1
2
1
2
3
6AT6
6AT17
6AT7
6AT42
6AT10
6AT18
6AT6-T
6AT7-T
6AT6-T2
6AT17-T2
Toggle/Rockers
6AT42-T2
6AT10-T
6AT10-T2
6AT18-T2
* Extra long toggle lever (.67 /17,0 mm).
Honeywell MICRO SWITCH Sensing and Control 1-800-537-6945 USA
1-815-235-6847 International 1-800-737-3360 Canada
131
Manual Switches
Toggle Switch Assemblies
13AT/23AT SERIES
AT Series
FEATURES
2 or 3-position, momentary and
maintained action.
2, 3 or 4 SPDT precision basic
switches.
Standard toggle, tab, or pull-to-unlock
levers.
Silver or gold contacts.
15
32
-inch bushing.
UL recognized, CSA certified basic
switches.
Lever-to-bushing seal option.
Standard lever
Tab lever
Pull-to-unlock
lever
ELECTRICAL RATINGS — Basic Switches
30 VDC Rating
Amps
UL/CSA Rating
Silver
Contacts
Gold
Contacts
5 amps,
125-250 VAC
1 amp,
125 VAC
Load
Inductive
Resistive
Max. Inrush
Inductive
Resistive
Max. Inrush
Sea Level
3
5
24
0.5
1
2
50,000 ft.
2.5
5
24
0.5
1
2
PULL-TO-UNLOCK TOGGLE
LEVERS
As a guard against accidental operation,
pull-to-unlock toggle levers must be
pulled .090 inch/2, 3 mm (approx.) to
change positions. A chart showing the 13
locking configurations and their catalog
listing suffix code letters is shown on next
page.
2-POSITION ORDER GUIDES
Toggle Lever Position
Keyway
Maint.
Opposite
Keyway
Maint.
No. of
Poles
2
3
4
Mom.
Maint.
2
3
4
1
See locking chart on next page.
Standard Lever
Type
Contacts
Silver
Gold
Silver
Gold
Silver
Gold
Silver
Gold
Silver
Gold
Silver
Gold
23AT6
23AT6-T2
Solder
Terminals
23AT1
23AT11
23AT2
23AT12
23AT3
23AT8
23AT4
23AT19
23AT5
23AT4-T
23AT4-T2
23AT3-T
23AT2-T
‘‘T’’
Terminals
23AT1-T
‘‘T2’’
Terminals
23AT1-T2
23AT11-T2
23AT2-T2
23AT12-T2
23AT3-T2
Tab Lever
‘‘T2’’
Terminals
23AT402-T2
Pull-To-Unlock Lever
Solder Terminals
(Add locking letter
1
to cat. listings below)
23AT1-
23AT11-
23AT2-
23AT12-
23AT3-
Locking letters:
D, F, or G
23AT403-T2
MIL-S-8805/26 Versions
Toggle Lever Position
Keyway
Maint.
Opposite
Keyway
Maint.
No. of
Poles
2
4
Type
Contacts
Silver
Silver
Standard Lever
‘‘T2’’ Terminals
Catalog Listing
23AT73-T2
23AT74-T2
Military No.
M8805/26-001
M8805/26-002
Tab Lever
‘‘T2’’ Terminals
Catalog Listing
23AT473-T2
23AT474-T2
Military No.
M8805/26-003
M8805/26-004
132
Honeywell MICRO SWITCH Sensing and Control 1-800-537-6945 USA
1-815-235-6847 International 1-800-737-3360 Canada
Manual Switches
Toggle Switch Assemblies
13AT/23AT SERIES
3-POSITION ORDER GUIDES
Toggle Lever Position
Keyway
Maint.
Center
Maint.
Opposite
Keyway
Maint.
No. of
Poles
2
3
4
Mom.
Maint.
Mom.
2
3
4
Maint.
Maint.
Mom.
2
4
Type
Contacts
Silver
Gold
Silver
Silver
Gold
Silver
Gold
Silver
Silver
Gold
Silver
Gold
Silver
13AT10
13AT410-T2 13AT10-
13AT3
13AT3-T
13AT3-T2
13AT403-T2 13AT3-
Solder
Terminals
13AT2
13AT18
13AT5
13AT9
13AT29
13AT1
13AT26
13AT4
13AT8
13AT8-T2
13AT1-T
13AT1-T2
13AT401-T2 13AT1-
13AT423-T2
13AT413-T2
13AT8-
13AT9-T2
Standard Lever
‘‘T’’
Terminals
13AT2-T
13AT18-T
13AT5-
13AT409-T2 13AT9-
‘‘T2’’
Terminals
13AT2-T2
Tab Lever
‘‘T2’’
Terminals
AT Series
Pull-To-Unlock Lever
Solder Terminals
(Add locking letter
to cat. listings below)
Locking letters:
All types
13AT402-T2 13AT2-
Locking Letters:
E, L, or N
Locking letters:
E, G, B, L, P or N
MIL-S-8805/26 VERSIONS
Toggle Lever Position
Keyway
Mom.
Maint.
Maint.
Center
Maint.
Maint.
Maint.
Opposite
Keyway
Mom.
Maint.
Mom.
No. of
Type
Poles Contacts
2
3
2
3
2
Silver
Silver
Silver
Silver
Silver
13AT272-T2
13AT275-T2
13AT273-T2
M8805/26-007
M8805/26-013
M8805/26-009
13AT473-T2
M8805/26-010
Standard Lever
‘‘T2’’ Terminals
Catalog Listing
13AT271-T2
Military No.
M8805/26-005
Tab Lever
‘‘T2’’ Terminals
Catalog Listing
13AT471-T2
13AT474-T2
13AT472-T2
Military No.
M8805/26-006
M8805/26-012
M8805/26-008
LEVER-TO-BUSHING SEAL OPTION
A splash type lever-to-bushing seal can
be provided to help prevent the entrance
of moisture and dust behind the panel, or
into the contact area. To specify 2-posi-
tion switches with lever-to-bushing seals,
change the 23AT catalog listing prefix to
32AT. Example:
32AT1
is a sealed 23AT1.
Convert 3-position catalog listings by
changing the 13AT prefix to 31AT. Exam-
ple:
31AT2-T
is a sealed 13AT2-T.
LOCKING CONFIGURATIONS
A
B
HERMETICALLY SEALED BASIC
SWITCH OPTION
AT’s with
15
32
bushings can be furnished
with HM or HS hermetically sealed basic
switches, which have metal-to-metal
fusion around the cover, actuator base
and mounting holes. Terminals are
sealed glass-to-metal. The
1
4
bushing
6AT design can also be provided with HM
basic switches. For more information,
contact the 800 number.
Shown with
HM basic switches
Toggle/Rockers
D
E
F
G
H
Locked In
Three Positions
J
Locked In
Center and
Extreme Position
(Keyway Side)
K
Locked Out
Of Center
Position
L
Locked In
Center Position
Locked In
Extreme Position
(Opposite Keyway)
M
Locked In
Extreme Position
(Keyway Side)
N
Locked Out Of
Center And
Extreme Position
(Keyway Side)
P
Locked Out Of
Center And
Extreme Position
(Opposite Keyway)
Locked In
Center And
Extreme Position
(Opposite Keyway)
Locked Out Of
Extreme Position
(Keyway Side)
Locked Out Of
And Into
Extreme Position
(Opposite Keyway)
Locked Out Of
Extreme Position
(Opposite Keyway)
Locked Out Of
And Into
Extreme Position
(Keyway Side)
133
Honeywell MICRO SWITCH Sensing and Control 1-800-537-6945 USA
1-815-235-6847 International 1-800-737-3360 Canada
Manual Switches
Toggle Switch Assemblies
MOUNTING DIMENSIONS
(For reference only)
13/23AT
AT Series
6AT
PANEL CUTOUTS
1
4
Bushing
15
32
Bushing
Bushing mounting torque is 10–15
in./lbs.
134
NOTE—
64AT300, 66AT300, and 68AT300 (M8805/98) listings have
a bushing seal and MS25196 panel seal.
1-815-235-6847 International 1-800-737-3360 Canada
Honeywell MICRO SWITCH Sensing and Control 1-800-537-6945 USA
查看更多>
嵌入式工程师必须懂fork与vfork~
fork() fork() 是用于创建新进程的系统调用之一,它会创建一个与当前进程完全相同的子进...
huaqingyuanjian 编程基础
Bootloader 的概念
简单地说,Bootloader 就是这么一小段程序,它在系统上电时开始执行,初始化硬件设备、准...
chenky 嵌入式系统
ADI活动 --- 签个到,就送礼!
活动页面: http://ezchina.analog.com/message/14728#14...
dontium ADI参考电路
晒WEBENCH设计的过程+LED电源设计
除了普通电源之外,WEBENCH可以方便的设计LED电源。 还是首先打开WEBENCH,在LED界面...
闲云潭影 模拟与混合信号
大学生用51单片机做的东西
昨天元宵节,单位提前两个小时放假,回家的时候路过学校,顺便去看了一下上学时教单片机的老师。老师给我...
jishuaihu 51单片机
VC2005开发嵌入式,如何得到模拟器的识别号(id)等标识信息
VC2005开发嵌入式,如何得到模拟器的识别号(id)等标识信息  做软件加密 VC2005开发嵌入...
manbuzhe 嵌入式系统
热门器件
热门资源推荐
器件捷径:
A0 A1 A2 A3 A4 A5 A6 A7 A8 A9 AA AB AC AD AE AF AG AH AI AJ AK AL AM AN AO AP AQ AR AS AT AU AV AW AX AY AZ B0 B1 B2 B3 B4 B5 B6 B7 B8 B9 BA BB BC BD BE BF BG BH BI BJ BK BL BM BN BO BP BQ BR BS BT BU BV BW BX BY BZ C0 C1 C2 C3 C4 C5 C6 C7 C8 C9 CA CB CC CD CE CF CG CH CI CJ CK CL CM CN CO CP CQ CR CS CT CU CV CW CX CY CZ D0 D1 D2 D3 D4 D5 D6 D7 D8 D9 DA DB DC DD DE DF DG DH DI DJ DK DL DM DN DO DP DQ DR DS DT DU DV DW DX DZ
需要登录后才可以下载。
登录取消