24060 has not been replaced. Please contact your customer
care centre for more information.
Main
Range of product
Range
Product name
Product or component type
Device short name
Device application
Poles description
Number of protected poles
[In] rated current
Network type
Trip unit technology
Curve code
Breaking capacity
C60
Multi 9
C60
Miniature circuit-breaker
C60N
Distribution
2P
2
0.5 A at 30 °C
DC
AC
Thermal-magnetic
C
10 kA Icu at 400...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
6000 A Icn at 230/400 V AC 50/60 Hz conforming to EN 60898
20 kA Icu at 125 V DC conforming to EN/IEC 60947-2
20 kA Icu at 230...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
30 kA Icu at 125 V DC conforming to EN/IEC 60947-2
40 kA Icu at <= 250 V DC conforming to EN/IEC 60947-2
Yes conforming to IEC 60947-2
Suitability for isolation
Complementary
Network frequency
[Ue] rated operational voltage
50/60 Hz
440 V AC 50/60 Hz
230...240 V AC 50/60 Hz
400...415 V AC 50/60 Hz
<= 250 V DC
230/400 V AC 50/60 Hz
5...10 x In
7.5 kA conforming to EN/IEC 60947-2 - 230...240 V AC 50/60 Hz
2.25 kA conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz
3.75 kA conforming to EN/IEC 60947-2 - 400...415 V AC 50/60 Hz
1
Magnetic tripping limit
[Ics] rated service breaking capacity
23 Jul, 2019
Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
6000 A conforming to EN 60898 - 230/400 V AC 50/60 Hz
Limitation class
Contact position indicator
Control type
Local signalling
Mounting mode
Mounting support
Comb busbar and distribution block
compatibility
9 mm pitches
Height
Width
Depth
Product weight
Mechanical durability
Connections - terminals
Tightening torque
Earth-leakage protection
Product compatibility
3 conforming to EN/IEC 60947-2
Yes
Toggle
ON/OFF indication
Clip-on
35 mm symmetrical DIN rail
NO
4
81 mm
36 mm
73 mm
0.24 kg
20000 cycles
Tunnel type terminals16 mm² flexible
Tunnel type terminals25 mm² rigid
Power circuit: 2 N.m upside
2 N.m downside
Separate block
C60 accessories
C60 auxiliary
Environment
Standards
IP degree of protection
Overvoltage category
Tropicalisation
Relative humidity
Operating altitude
Ambient air temperature for operation
Ambient air temperature for storage
EN/IEC 60947-2
EN 60898
IP20 conforming to IEC 60529
IV
2 conforming to IEC 60068-1
95 % at 55 °C
2000 m
-25…60 °C
-40…70 °C
Offer Sustainability
Sustainable offer status
REACh Regulation
EU RoHS Directive
Mercury free
RoHS exemption information
China RoHS Regulation
Environmental Disclosure
Circularity Profile
WEEE
Green Premium product
REACh Declaration
Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS Declaration
Yes
Yes
Download RoHS China Declaration
Product Environmental Profile
No need of specific recycling operations
The product must be disposed on European Union markets following specific waste collection and