https://www.phoenixcontact.com/us/products/2904961
Repeater power supply - MACX PL-RPSSI-2I - 2904961
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Measuring transducer power supply and input signal conditioner, HART-transparent. Transfers supplied or active
4 - 20 mA electrically isolated signals from the field to two loads. 4-way electrical isolation, PLd
Product Features
Packing unit
1 pc
240.0 GRM
85437090
Germany
Key commercial data
Weight per Piece (excluding packing)
Custom tariff number
Country of origin
Technical data
Note
Utilization restriction
EMC: class A product, see manufacturer's declaration in the download
area
Dimensions
Width
Height
Depth
12.5 mm
99 mm
114.5 mm
Ambient conditions
Ambient temperature (operation)
Ambient temperature (storage/transport)
Maximum altitude
Permissible humidity (operation)
-20 °C ... 60 °C (Any mounting position)
-40 °C ... 80 °C
≤ 2000 m
10 % ... 95 % (non-condensing)
05/18/2015 Page 1 / 5
https://www.phoenixcontact.com/us/products/2904961
Repeater power supply - MACX PL-RPSSI-2I - 2904961
Technical data
Ambient conditions
Noise immunity
Degree of protection
EN 61000-6-2 When being exposed to interference, there may be minimal
deviations.
IP20
Input data
Signal input
Current input signal
Transmitter supply voltage
Signal input
Current input signal
Voltage drop
Repeater power supply operation
4 mA ... 20 mA
> 21.5 V (20 mA)
> 21 V (23 mA)
Signal conditioner operation
4 mA ... 20 mA
< 3.9 V
Output data
Signal output
Current output signal
Load/output load current output
Output ripple
Output behavior in the event of an error
Signal output
Current output signal
Load/output load current output
Output ripple
Output behavior in the event of an error
Repeater power supply operation
4 mA ... 20 mA (active)
< 450 Ω (20 mA)
< 380 Ω (23 mA)
< 20 mV
rms
0 mA (Cable break in the input)
0 mA (Cable short-circuit in the input)
Signal conditioner operation
4 mA ... 20 mA (active)
< 450 Ω (20 mA)
< 380 Ω (23 mA)
< 20 mV
rms
0 mA (Cable break in the input)
≥ 23 mA (Cable short-circuit in the input)
Power supply
Designation
Supply voltage range
Max. current consumption
Power consumption
Repeater power supply operation
19.2 V DC ... 30 V DC (24 V DC (-20% ... +25%))
< 75 mA (24 V DC / 20 mA)
< 1.45 W (24 V DC/ 20 mA)
Connection data
Conductor cross section solid min.
Conductor cross section solid max.
Conductor cross section flexible min.
Conductor cross section flexible max.
0.2 mm²
2.5 mm²
0.2 mm²
2.5 mm²
05/18/2015 Page 2 / 5
https://www.phoenixcontact.com/us/products/2904961
Repeater power supply - MACX PL-RPSSI-2I - 2904961
Technical data
Connection data
Conductor cross section AWG min.
Conductor cross section AWG max.
Stripping length
Screw thread
Connection method
Tightening torque, min
Tightening torque max
24
14
7 mm
M3
Screw connection
0.5 Nm
0.6 Nm
General
Maximum transmission error
Transmission error, typical
Maximum temperature coefficient
Step response (10-90%)
Status display
Inflammability class according to UL 94
Electromagnetic compatibility
Housing material
Color
Designation
Electrical isolation
< 0.1 % (of final value)
< 0.05 % (of final value)
< 0.01 %/K
< 1.3 ms (for 4 mA ... 20 mA step)
Green LED (PWR supply voltage)
V0
Conformance with EMC Directive 2004/108/EC
PA 66-FR
yellow
Input/output/power supply
300 V
rms
(Rated insulation voltage (surge voltage category II; pollution
degree 2, safe isolation as per EN 61010-1))
2.5 kV (50 Hz, 1 min., test voltage)
Designation
Electrical isolation
Conformance
ATEX
Output 1/output 2
1.5 kV AC (50 Hz, 1 min., test voltage)
CE-compliant, additionally EN 61326
II 3 G Ex nA IIC T4 Gc X
Data communication (bypass)
HART function
Protocols supported
Yes
HART
EMC data
Designation
Standards/regulations
Typical deviation from the measuring range final value
Designation
Standards/regulations
Typical deviation from the measuring range final value
Designation
Electromagnetic RF field
EN 61000-4-3
3%
Fast transients (burst)
EN 61000-4-4
3%
Conducted interferences
05/18/2015 Page 3 / 5
https://www.phoenixcontact.com/us/products/2904961
Repeater power supply - MACX PL-RPSSI-2I - 2904961
Technical data
EMC data
Standards/regulations
Typical deviation from the measuring range final value
EN 61000-4-6
3%
Classifications
eCl@ss
eCl@ss 5.1
eCl@ss 6.0
eCl@ss 8.0
27210120
27061801
27210120
ETIM
ETIM 4.0
ETIM 5.0
EC002653
EC002653
Approvals
Approvals
Approvals
UL Listed / cUL Listed / GL / cULus Listed
Ex Approvals
Approvals submitted
Approval details
UL Listed
cUL Listed
GL
05/18/2015 Page 4 / 5
https://www.phoenixcontact.com/us/products/2904961
Repeater power supply - MACX PL-RPSSI-2I - 2904961
Approvals
cULus Listed
Drawings
Block diagram
Sensor / Field
IN
OUT
PLC / DCS
4.2 - 4.2
3.2 - 3.2
-
+
passive
OUT 1
4.1
HHT
+
4.1
3.1
+
3.1
HHT
or
2.2
2.2
2.1
-
+
HHT
OUT 2
5.2 - 5.2
5.1
HHT
2.1
+
5.1
GND
+24V
Power
GND +24V
1.2
1.1
passive
Zone 2
Div. 2
Phoenix Contact 2015 © - all rights reserved
http://www.phoenixcontact.com
05/18/2015 Page 5 / 5