Supplement
Title: 34XR-A Users
Supplement Issue: 2
Part Number: 2728939 Issue Date:
9/06
Print Date: July 2006 Page Count:
1
Revision/Date:
This supplement contains information
necessary to ensure the accuracy of the
above manual.
© 2006 Amprobe© Test Tools. All rights reserved.
34XR-A Users
Supplement
Change #1
On page 9, under
General Specification,
change
Operating environment:
From: 0
ºC
to 50
ºC
at <70% R.H.
To:
0
ºC
to 50
ºC
at <70% R.H. for all functions
except 10A ranges
10A ranges: 0
ºC
to 40
ºC
at <70% R.H.
Change #2
On page 9, following
Operating environment
add:
10A Ranges: 0
ºC
to 40
ºC
at < 70 % R.H.
On page 10, under
AC CURRENT,
following Crest
Factor add the following:
Specified From: 10 % to 100% of range
On page 11, under
FREQUENCY
change:
From: Range: 4K, 40K, 400K 4M, 40MHz
To:
Range: 4K, 40K, 400K, 1 MHz
Under Sensitivity, change the following and delete,
4 MHz to 40 MHz: >2 V ac rms, <5 V ac rms
From: 10 Hz 4 MHz: >1.5 V acrms
To:
10 Hz to 1 MHz: >2.5 V ac rms
From: Minimum pulse width: > 25 ns
To:
Minimum pulse width: > 1
µs
9/06
1
34XR-A
1
5
2
MADE IN TAIWAN
PATENTS PENDING
www.amprobe.com
3
( )
6
( )
4
34XR-A
34XR-A
Professional Digital Multimeter
Users Manual
•
Mode d’emploi
•
Bedienungshandbuch
•
Manuale d’Uso
•
Manual de uso
PN 2728939
July 2006
©Amprobe© Test Tools.
All rights reserved. Printed in Taiwan.