INIATURE
M
INIATURE
F
USES
WICKMANN
6.3x32mm / No. 356
Type, 440V,
Special Type, 440V, T
Time-Current Characteristic
Time Lag (T)
Specifications
Packaging
000: Bulk (500 pcs.)
002: Pack (100 pcs.)
Standard
None
Materials
Tube:
End Caps:
Ceramic
Nickel-plated brass
Approvals
cULus Recognized: File No. E 67006
Features
For high voltage applications
Surge tolerant
High breaking capacity
Agency approved
Pluggable into clips or shocksafe holders
Temperature
Operating Temperature
-25ºC to +70ºC (consider de-rating)
Climatic Category
-25ºC/+70ºC/21 days (EN 60068-1..3)
Stock Conditions
+10ºC to +60ºC
relative humidity
≤
75% yearly average,
without dew, maximum value for 30 days-95%
Dimensions (mm)
WebLinks
Data Sheet
∅
6,3
32
Vibration Resistance
24 cycles at 15 min. each (EN 60068-6)
10 - 60Hz at 0.75mm amplitude
60 - 2000Hz at 10g acceleration
www.wickmann.com/products/356.pdf
Approval Certificates
www.wickmann.com/approvals
T ime-Current Curve
www.wickmann.com/itcurves
Marking
, T, Current Rating, 440V, Approvals
FaxBack Document # 212
Weight
Unit Weight
3.0g (approx.)
Limits for Pre-arcing Time
Rated Current
400mA ... 10.00A
1.5 x I
Rated
> 1h
2.5 x I
Rated
< 15 min
4 x I
Rated
150ms ... 2s
10 x I
Rated
10ms ... 300ms
100%
Permissible continuous operating current is
≤
100% at ambient temperature of 23ºC (73.4ºF).
Rated
Amp
Voltage
Breaking
Voltage Drop Power Dissipation Melting Integral
Current
Code
Rating
Capacity
1.0 x I
Rated
1.5 x I
Rated
10 x I
Rated
max. (mV)
max. (W)
min. (A
2
s)
400mA
500mA
630mA
800mA
1.00A
1.25A
1.60A
2.00A
2.50A
3.15A
4.00A
5.00A
1
6.30A
1
8.00A
1
10.00A
1
0400
0500
0630
0800
1100
1125
1160
1200
1250
1315
1400
1500
1630
1800
2100
440V
440V
440V
440V
440V
440V
440V
440V
440V
440V
440V
440V
440V
440V
440V
1200
1100
800
700
500
350
320
270
250
230
200
180
150
140
120
1.5
1.6
1.7
1.7
1.8
1.8
1.8
2.0
2.3
2.4
2.6
3.0
3.2
3.8
4.0
0.16
0.53
2.0
3.1
4.4
3.1
8.3
9.2
22
36
62
91
130
240
510
Approvals
cURus
1000A / 440VAC
50-60Hz
cos
ϕ
= 1.0
•
•
•
•
•
•
•
•
•
•
•
1 Depending on the application and mounting, the fuse heating at max. ambient temperature in a closed fuseholder should be considered.
Order
Information
000801
Qty.
Order-
Number
Series
356
Amp Code
Packaging
WebSite:
www.wickmann.com
FaxBack: +1 (404) 699-6176
• Europe
Tel: +49 (2302) 662-107
• Americas
Tel: +1 (404) 699-7820
• Asia
Tel: +852 26 14-1108
E-mail: sales@wickmann.com
E-mail: service@wickmannusa.com E-mail: sales@wickmann.com.hk
INIATURE
M
INIATURE
F
USES
WICKMANN
6.3x32mm / No. 356
00
Time (sec.)
000801
WebSite:
www.wickmann.com
FaxBack: +1 (404) 699-6176
10
0 ,0
10
,0 0
0
1 ,0
00
10
0
10
1
0 .1
0 .0
1
0 .0
01
I-t Cha racteristic s
(M in-M ax Lim it)
1
1 .5
2
3
4
5
6
7
8 9 10
15
I
Fault
/ I
Rated
Contact WICKMANN for individual I-t curves
• Europe
Tel: +49 (2302) 662-107
• Americas
Tel: +1 (404) 699-7820
• Asia
Tel: +852 26 14-1108
E-mail: sales@wickmann.com
E-mail: service@wickmannusa.com E-mail: sales@wickmann.com.hk