0805 Moulded Chip Inductor
Type 3610 Series
Type 3610 Series
Characteristics -
Electrical
Inductance
Code
10N
12N
15N
18N
22N
27N
The 3610 series is a very small wound
inductor creating high Q and self
resonant frequency. A good spread of
inductance values is supported by
typical 5% and 10% tolerances
Please enquire for custom solutions.
Inductance
(µH)
0.010
0.012
0.015
0.018
0.022
0.027
0.033
0.039
0.047
0.056
0.068
0.082
0.10
0.12
0.15
0.18
0.22
0.27
0.33
0.39
0.47
0.56
0.68
0.82
1.00
Tolerance
(±%)
10
10
10
10
10
10
5/10
5/10
5/10
5/10
5/10
5/10
5/10
5/10
5/10
5/10
5/10
5/10
5/10
5/10
5/10
5/10
5/10
5/10
5/10
Q
Min
10
10
12
12
15
15
15
15
15
15
15
15
8
8
10
10
10
10
10
10
10
10
10
10
8
LQ Test
Freq. (MHz)
100
100
100
100
100
100
100
100
100
100
100
100
25.2
25.2
25.2
25.2
25.2
25.2
25.2
25.2
25.2
25.2
25.2
25.2
7.96
S.R.F.
(MHz) Min
3300
3300
3000
3000
2600
2500
2050
2000
1650
1550
1450
1100
800
600
600
600
500
300
200
150
150
100
100
80
80
Rdc Max
(ohms)
0.18
0.24
0.24
0.29
0.29
0.34
0.39
0.41
0.46
0.51
0.57
0.63
0.86
0.99
1.47
1.61
1.84
1.95
2.16
2.37
2.56
2.69
3.02
3.38
3.88
Idc
(mA) Max
540
535
520
480
465
455
395
390
385
360
340
330
285
275
230
195
170
165
160
150
145
140
130
125
120
33N
39N
47N
56N
68N
82N
R10
R12
R15
R18
R22
R27
R33
R39
R47
R56
R68
R82
1R0
Key Features
I
I
I
I
I
I
I
I
Innovative 08:05 Package
Fully Moulded Construction
Smooth Top Aids Placement
10NH to 1µH Value Range
Laboratory Design Kits
Available
High Q Factor
High S.R.F.
Standard Tolerances
Q vs Frequency
Curve
Q
R10
47N
15N
10N
160
120
80
40
0
10M
100M
Frequency (Hz)
1G
3G
Dimensions
How to Order
3610
Common Part
3610 - 0805
Moulded Inductor
T
Orientation
R10
Inductance Value
J
Tolerance
J - ±5%
T - Standard Package
See Table Above
K - ±10%
Literature No. 1773140
Issued: 08-05
Dimensions are shown for
reference purposes only.
Dimensions are in millimetres
unless otherwise specified.
Specifications subject to
change.
www.tycoelectronics.com