首页 > 器件类别 > 电路保护 > 电路保护

3RV1431-4EA10

Thermal Magnetic Circuit Breaker, 3 Pole(s), 32A, 690VAC, Din-rail Mount,

器件类别:电路保护    电路保护   

厂商名称:SIEMENS

厂商官网:http://www.infineon.com/

下载文档
器件参数
参数名称
属性值
厂商名称
SIEMENS
Reach Compliance Code
unknown
主体宽度
55 mm
主体高度
149 mm
主体长度或直径
140 mm
电路功能
TRIP
电路保护类型
THERMAL MAGNETIC
环境特性
IP20
安装特点
DIN-RAIL MOUNT
极数
3
物理尺寸
140mm x 55mm x 149mm
额定分断能力
4000 A
额定电流
32 A
额定电压(交流)
690 V
参考标准
CCC; CE; CSA; EAC; UL; VDE
表面贴装
NO
端子形状
SCREW AND SNAP ON
Base Number Matches
1
文档预览
Data sheet
3RV1431-4EA10
Circuit breaker size S2 For transformer protection A-release 22...32
A Short-circuit release 660 A Screw terminal Standard switching
capacity !!! Phased-out product !!! Successor is SIRIUS 3RV2
Preferred successor type is >>3RV2431-4EA10<<
Product brand name
Product designation
Design of the product
SIRIUS
circuit breaker
for transformer protection
General technical data
Product extension
● Auxiliary switch
Power loss [W] total typical
Surge voltage resistance rated value
Protection class IP
● on the front
Shock resistance
Mechanical service life (switching cycles)
● of the main contacts typical
Continuous current rated value
50 000
32 A
IP20
25g / 11 ms
Yes
15 W
6 000 V
Ambient conditions
Installation altitude at height above sea level
● maximum
2 000 m
Main circuit
3RV1431-4EA10
Page 1/5
05/06/2019
Subject to change without notice
© Copyright Siemens
Number of poles for main current circuit
Adjustable pick-up value current of the current-
dependent overload release
Operating voltage
● rated value
● at AC-3 rated value maximum
Operating current
● at AC-3
— at 400 V rated value
Operating frequency
● at AC-3 maximum
3
22 ... 32 A
690 V
690 V
32 A
15 1/h
Auxiliary circuit
Number of CO contacts
● for auxiliary contacts
0
Protective and monitoring functions
Product function
● Ground fault detection
● Phase failure detection
(trip class)
Maximum short-circuit current breaking capacity (Icu)
● at AC at 240 V rated value
● at AC at 400 V rated value
● at AC at 500 V rated value
● at AC at 690 V rated value
100 kA
50 kA
10 kA
4 kA
No
Yes
CLASS 10
Short-circuit protection
Design of the overcurrent release and short-circuit
release
thermomagnetic
Installation/ mounting/ dimensions
● (mounting position)
● (mounting type)
(height)
Width
Depth
Required spacing
● with side-by-side mounting
— Backwards
— at the side
0 mm
0 mm
any
screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 50022
140 mm
55 mm
149 mm
Connections/Terminals
Product function
3RV1431-4EA10
Page 2/5
05/06/2019
Subject to change without notice
© Copyright Siemens
● removable terminal for auxiliary and control
circuit
Type of electrical connection
● for main current circuit
● for auxiliary and control current circuit
Arrangement of electrical connectors for main current
circuit
Type of connectable conductor cross-sections
● for main contacts
— solid
— stranded
— finely stranded with core end processing
● at AWG conductors for main contacts
No
screw-type terminals with box terminals
screw-type terminals
front side
2x (0.75 ... 16 mm²)
2x (0.75 ... 25 mm²), 1x (0.75 … 35 mm²)
2x (0.75 ... 16 mm²), 0.75 ... 25 mm²
2x (18 ... 2), 1x (18 ... 2)
Certificates/approvals
General Product Approval
Declaration of Conformity
Miscellaneous
Test Certificates
Special Test Certi-
ficate
Type Test Certific-
ates/Test Report
Marine / Shipping
Marine / Ship-
ping
other
Miscellaneous
Confirmation
Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
http://www.siemens.com/industrial-controls/catalogs
Industry Mall (Online ordering system)
https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RV1431-4EA10
Cax online generator
http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RV1431-4EA10
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
https://support.industry.siemens.com/cs/ww/en/ps/3RV1431-4EA10
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RV1431-4EA10&lang=en
3RV1431-4EA10
Page 3/5
05/06/2019
Subject to change without notice
© Copyright Siemens
Characteristic: Tripping characteristics, I²t, Let-through current
https://support.industry.siemens.com/cs/ww/en/ps/3RV1431-4EA10/char
Further characteristics (e.g. electrical endurance, switching frequency)
http://www.automation.siemens.com/bilddb/index.aspx?view=Search&mlfb=3RV1431-4EA10&objecttype=14&gridview=view1
30
∅5
SIEMENS
45
100
140
55
5
8
64
144
3RV1431-4EA10
Page 4/5
05/06/2019
Subject to change without notice
© Copyright Siemens
129
1/L1
3/L2
I>
-F
I>
2/T1
4/T2
last modified:
05/04/2019
3RV1431-4EA10
Page 5/5
6/T3
Subject to change without notice
© Copyright Siemens
05/06/2019
5/L3
I>
查看更多>
热门器件
热门资源推荐
器件捷径:
A0 A1 A2 A3 A4 A5 A6 A7 A8 A9 AA AB AC AD AE AF AG AH AI AJ AK AL AM AN AO AP AQ AR AS AT AU AV AW AX AY AZ B0 B1 B2 B3 B4 B5 B6 B7 B8 B9 BA BB BC BD BE BF BG BH BI BJ BK BL BM BN BO BP BQ BR BS BT BU BV BW BX BY BZ C0 C1 C2 C3 C4 C5 C6 C7 C8 C9 CA CB CC CD CE CF CG CH CI CJ CK CL CM CN CO CP CQ CR CS CT CU CV CW CX CY CZ D0 D1 D2 D3 D4 D5 D6 D7 D8 D9 DA DB DC DD DE DF DG DH DI DJ DK DL DM DN DO DP DQ DR DS DT DU DV DW DX DZ
需要登录后才可以下载。
登录取消