首页 > 器件类别 > 电线/电缆

5120UM 0021000

Multi-Conductor Cables 14AWG 2C UNSHLD 1000ft SPOOL RED

器件类别:电线/电缆   

厂商名称:Belden Wire & Cable

器件标准:

下载文档
器件参数
参数名称
属性值
Product Attribute
Attribute Value
制造商
Manufacturer
Belden Wire & Cable
产品种类
Product Category
Multi-Conductor Cables
Shipping Restrictions
Due to size or weight of the product, your shipping charge may increase.
RoHS
Details
类型
Type
Commercial Audio Applications
Number of Conductors
2 Conductor
长度
Length
1000 ft
Wire Gauge - AWG
14 AWG
Jacket Color
Black
Outside Diameter
9.14 mm
Jacket Material
Polyethylene (PE)
Stranding
Solid
电压额定值
Voltage Rating
300 V
工厂包装数量
Factory Pack Quantity
1
单位重量
Unit Weight
73 lbs
文档预览
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
5120UM Multi-Conductor - Commercial Applications - 2 Cond Cabled
For more Information
please call
1-800-Belden1
General Description:
14 AWG solid bare copper conductors, ceramifiable silicone insulation, FRPE (low smoke non-halogen)
jacket, sequential footage marking every two feet.
Usage (Overall)
Suitable Applications:
Survivability, Survivability from Attach by Fire, Fire Alarm Circuit Integrity, CI, Survivability by NFPA72,
Sim to MI, Similar to Mineral Insulated, FPLR-CI, Emergency Circuits, Notification Devises, Fire Pumps, 2
hour fire rating
Physical Characteristics (Overall)
Conductor
AWG:
# Conductors AWG Stranding Conductor Material
2
14
Solid
BC - Bare Copper
2
Total Number of Conductors:
Insulation
Insulation Material:
Insulation Material Wall Thickness (in.)
Silicone Rubber
.034
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
Nom. Wall Thickness (in.)
FRPE - Flame Retardant Polyethylene .045
Overall Cable
Overall Cabling Color Code Chart:
Number Color
1
2
Black
Red
0.358 in.
Overall Nominal Diameter:
Mechanical Characteristics (Overall)
Operating Temperature Range:
UL Temperature Rating:
Bulk Cable Weight:
Max. Recommended Pulling Tension:
Min. Bend Radius/Minor Axis:
-20°C To +105°C
105°C
65 lbs/1000 ft.
99.400 lbs.
3.750 in.
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification:
NEC Articles:
EU Directive 2011/65/EU (ROHS II):
EU CE Mark:
EU Directive 2000/53/EC (ELV):
EU Directive 2002/95/EC (RoHS):
EU RoHS Compliance Date (mm/dd/yyyy):
EU Directive 2002/96/EC (WEEE):
EU Directive 2003/11/EC (BFR):
CA Prop 65 (CJ for Wire & Cable):
MII Order #39 (China RoHS):
FPLR-CI
760
Yes
Yes
Yes
Yes
01/01/2005
Yes
Yes
Yes
Yes
Page 1 of 2
09-11-2017
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
5120UM Multi-Conductor - Commercial Applications - 2 Cond Cabled
MII Order #39 (China RoHS):
Yes
Flame Test
UL Flame Test:
UL1666 Riser, UL2196 Two Hour Circuit Integrity
Plenum/Non-Plenum
Plenum (Y/N):
No
Electrical Characteristics (Overall)
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/ft)
21
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
2.6
Max. Operating Voltage - UL:
Voltage
41 V RMS
Description
CI applications
300 V RMS FPLR only applications
Put Ups and Colors:
Item #
Putup
Ship Weight
Color
Notes
Item Desc
Revision Number: 2
© 2017 Belden, Inc
All Rights Reserved.
Revision Date: 11-12-2012
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to
change without notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for
any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether
in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities
and in our Distributor’s inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is
correct to the best of Belden’s knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the
safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification.
Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the
product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 2014/35/EU).
Page 2 of 2
09-11-2017
查看更多>
热门器件
热门资源推荐
器件捷径:
L0 L1 L2 L3 L4 L5 L6 L7 L8 L9 LA LB LC LD LE LF LG LH LI LJ LK LL LM LN LO LP LQ LR LS LT LU LV LW LX LY LZ M0 M1 M2 M3 M4 M5 M6 M7 M8 M9 MA MB MC MD ME MF MG MH MI MJ MK ML MM MN MO MP MQ MR MS MT MU MV MW MX MY MZ N0 N1 N2 N3 N4 N5 N6 N7 N8 NA NB NC ND NE NF NG NH NI NJ NK NL NM NN NO NP NQ NR NS NT NU NV NX NZ O0 O1 O2 O3 OA OB OC OD OE OF OG OH OI OJ OK OL OM ON OP OQ OR OS OT OV OX OY OZ P0 P1 P2 P3 P4 P5 P6 P7 P8 P9 PA PB PC PD PE PF PG PH PI PJ PK PL PM PN PO PP PQ PR PS PT PU PV PW PX PY PZ Q1 Q2 Q3 Q4 Q5 Q6 Q8 Q9 QA QB QC QE QF QG QH QK QL QM QP QR QS QT QV QW QX QY R0 R1 R2 R3 R4 R5 R6 R7 R8 R9 RA RB RC RD RE RF RG RH RI RJ RK RL RM RN RO RP RQ RR RS RT RU RV RW RX RY RZ
需要登录后才可以下载。
登录取消