Wire Wound Chip Inductors
——O-Series
0603(1608)/5506
Features
1. Coil body of ceramic material.
2. Two solderable metallized terminations of Ag/Pd/Pt.
3. Wound with lacquer-coated copper wire.
4. Wire ends welded onto the terminations.
5. Lead Free (RoHS Compliance)
PAGE
1/3
Applications
1. RF technique
2. Antenna Amplifiers Tuners, Base Stations or SAT Receivers.
Ordering Information
5506
(1)
270
(2)
*
(3)
*
(4)
**
(5)
(4)
Delivery Form
3: coated, bulk
4 : coated, tape & reel
(5) Packing unit tape & reel
00 : reels
Φ180mm,
4,000 pcs.
(1) Series
- 5506 : Size 0603(1608)
(2) Inductance Value
example: 27x10
X
=27x10
0
=27(nH)
(3) Inductance Tolerance
1 : ±20%
4 : ±2%
2 : ±10%
9 : special tolerance
3 : ±5%
Shape and Dimensions (mm)
Pad Layout Recommendation
a
0,8 ~ 1,0
b
2,0 ~2,5
c
0,7 ~ 0,9
*All specifications are subject to change without notice.
Wire Wound Chip Inductors
——O-Series
0603(1608)/5506
Electrical Parameters
Order No.
5506 015 ** **
5506 018 ** **
5506 033 ** **
5506 036 ** **
5506 039 ** **
5506 047 ** **
5506 056 ** **
5506 068 ** **
5506 082 ** **
5506 087 ** **
5506 100 ** **
5506 120 ** **
5506 150 ** **
5506 180 ** **
5506 220 ** **
5506 270 ** **
5506 330 ** **
5506 390 ** **
5506 470 ** **
5506 560 ** **
5506 680 ** **
5506 820 ** **
5506 101 ** **
5506 121 ** **
5506 151 ** **
5506 181 ** **
5506 221 ** **
5506 271 ** **
5506 331 ** **
5506 391 ** **
PAGE
2/3
L
[nH]
1,5
1,8
3,3
3,6
3,9
4,7
5,6
6,8
8,2
8,7
10
12
15
18
22
27
33
39
47
56
68
82
100
120
150
180
220
270
330
390
Q
min
22
22
30
35
35
28
35
40
40
35
45
40
45
45
45
45
45
45
40
40
40
35
35
35
30
30
30
30
30
30
Q
typ
@800MHz
f
L,Q
[MHz]
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
200
200
200
150
150
150
100
100
100
100
100
100
f
res,min
[MHz]
6000
6000
6000
6000
6000
6000
6000
5600
5500
5300
5000
4100
3300
3700
3100
2900
2550
2150
2050
2000
1700
1700
1550
1300
1200
1150
1050
990
890
810
D.C.R. ,max
[mΩ ]
25
35
40
35
35
75
40
35
60
60
45
90
55
90
135
115
115
120
200
290
360
590
890
1100
1200
1300
1900
2100
2900
4000
I
N,max
[mA]
1000
900
800
900
900
620
840
890
700
700
780
560
710
560
450
500
490
480
380
310
280
220
180
160
150
140
120
115
95
80
Tol.
[%]
10/20
10/20
10/20
10/20
10/20
10/20
5/10/20
5/10/20
5/10/20
5/10/20
2/5/10
2/5/10
2/5/10
2/5/10
2/5/10
2/5/10
2/5/10
2/5/10
2/5/10
2/5/10
2/5/10
2/5/10
2/5/10
2/5/10
2/5/10
2/5/10
2/5/10
2/5/10
2/5/10
2/5/10
45
35
55
50
50
45
60
70
55
70
80
70
80
75
70
70
70
65
55
50
50
60
50
50
40
35
30
-
-
-
All values on ceramic core.
*All specifications are subject to change without notice.
Wire Wound Chip Inductors
——O-Series
0603(1608)/5506
Electrical Characteristic Curves
Typical Q factor vs. frequency
PAGE
3/3
Typical Inductance vs. frequency
Climatic category acc. to DIN IEC 68-1:55/125/56
Test equipment : Inductance and Q: Agilent 42286A+16193A.
Resonant Frequency : Agilent 8753E.
D.C.R. : Burst Resistomat 2329.(at20℃)
*All specifications are subject to change without notice.