59140 and 59141 MINI FLANGE MOUNT SERIES
Benefits
Applications
Features
Magnetically operated position sensor
No standby power requirement
Position and limit sensing
Matching actuator available
Operates through non-ferrous
Security system switch
materials such as wood, plastic
Compact size requires only 3.2cm²
Linear actuators
or aluminium
board space
Door switch
Hermetically sealed, magnetically
Screw down or adhesive mounting
operated contacts continue to
Customer defined sensitivity
operate long after optical and other
Choice of cable length and connector
technologies fail due to contamination
Leads can exit from LH or RH side
DIMENSIONS
(in) mm
Actuator
(.236)
6.00
(.906)
23.00
SCHEMATICS
Sensor (2 wire versions)
(.236)
6.00
(.906)
23.00
(Not including encapsulant)
Table3 ±(.393) 10.00
(.250)
6.35 Nom.
(.295)
(.295)
(.433)
(.433)
11.00
(.551)
(.551)
14.00
14.00
11.00
Switch Types 1 & 2
Black
Black
Switch Type 3
Black
Blue
White
7.50
7.50
(.118)
3.00
Slot (.126x.150)
3.20x3.81 Typ.
(.551)
14.00
(.118)
3.00
Slot (.126x.150)
3.20x3.81 Typ.
(.551)
14.00
Note: 59140 shown
59141 leads exit opposite side
Switch Type
4
Black
Black
CUSTOMER OPTIONS - Switching Specifications
TABLE 1
Switch Type
Select Option
Contact Type
Contact Rating
Voltage
Power
Switching
Breakdown
Current
Switching
Carry
Resistance
Contact, Initial
Insulation
Temperature
Operating
Storage
Time
Operate
Release
Capacitance
Shock
Vibration
Contact
11ms ½ sine
50-2000 Hz.
Watts - max
Vdc - max.
Vdc - min.
A - max.
A - max.
Ohms - max.
Ohms - min.
°C
°C
ms - max.
ms - max.
pF - typ.
G - max.
G - max.
1
Normally Open
10
200
250
0.5
1.2
0.2
10
10
-40 to +105
-65 to + 105
1.0
1.0
0.3
100
30
2
Normally Open High V.
10
300
450
0.5
1.5
0.2
10
10
-20 to +105
-65 to +105
1.0
1.0
0.2
100
30
3
Change Over
5
175
200
0.25
1.5
0.2
10
9
-40 to +105
-65 to +105
3.0
3.0
0.3
50
30
4
Normally Closed
5
175
200
0.25
1.5
0.2
10
9
-40 to +105
-65 to +105
3.0
3.0
0.3
50
30
CUSTOMER OPTIONS - Sensitivity, Cable Length and Termination Specifications
TABLE 2
Sensitivity
d
TABLE 3
Cable Length
TABLE 4
Select Option
Termination
(2 wire versions shown)
Description
Diagram
Activate distances (d) are
approximate using Hamlin
57140-000 actuator as illustrated.
Switch AT before modification
Select
Option
(Cable 24AWG 7/32 PVC
105°C
UL1430 / ULl569)
Select Option
Length(in)mm
A
C
D
E
Tinned leads
6.35mm fastons
AMP MTE 2.54mm
JST XHP 2.5mm
01
02
U
V
(3.94) 100
(11.81) 300
(19.69) 500
(29.53) 750
(39.37) 1,000
S
T
Pull-In Activate Pull-In Activate Pull-In Activate Pull-In Activate
AT Distance AT Distance AT Distance AT Distance
Range
(d)
Range
(d)
Range (d)
Range
(d)
(in)mm
(in)mm
(in)mm
(in)mm
12-18
(.453)
11.5
15-20
(.413)
10.5
17-23
(.374)
9.5
(.354)
9.0
22-28
(.315)
8.0
(.295)
7.5
27-33
(.295)
7.5
03
04
05
1
2
3
4
Hamlin USA
Hamlin UK
Hamlin Germany
Hamectrol France
Switch Type
F
Untinned leads
ORDERING INFORMATION
Series 59140/59141
Switch Type
Sensitivity
Cable Length
Termination
59140/59141
X
X
XX
X
20-25
25-30
Table 1 (1, 2, 3 or 4)
Table 2 (S, T, U or V)
Table 3 (01, 02, 03, 04 or 05)
Table 4 (A, C, D, E or F)
Tel: +1 920 648 3000 Fax: +1 920 648 3001 Email: sales.us@hamlin.com
DETAILS ON THIS DATA SHEET ARE PROVIDED FOR INFORMATION PURPOSES ONLY &
SHOULD NOT BE RELIED UPON AS BEING ACCURATE FOR ANY PARTICULAR PURPOSE
Tel: +44 (0) 1379 649700 Fax: +44 (0) 1379 649702 Email: sales.uk@hamlin.com
Product performance may be affected by the application that the part is used for.
Upon request Hamlin will assist purchasers by providing information specific to a particular application.
liability whatsoever for any purchaser’s reliance upon the information
Tel: +49 (0) 6181 953660 Fax: +49 (0) 6181 9536666 Email: sales.de@hamlin.com
Hamlin disclaims allsheet without further consultation with Hamlin’s authorised representatives.
contained in this data
Tel: +33 (0) 1 4687 Fax: +33 (0) 1 4686 6798 Email: sales.fr@hamlin.com
Issue:AB 05/02/09 DCR:B6092
查看更多>
ARM的一个简单调试问题
为什么在用ADS1.2调试程序时,如果主函数是main.c 就不能把.inc文件加到项目中。调试程序...
torresgerrard ARM技术
CCS6 新建TMS320F2812工程
CCS 6新建TMS320F2812工程 准备材料 CCS6 下载地址: h...
一个人游 微控制器 MCU
安森美推出新型保护与滤波器件
安森美半导体日前推出五款新型MicroIntegration电路,针对保护便携和计算机应用中的敏感元...
fighting 模拟电子
请教如何判断烧进AVR芯片里的程序有多大?
请教如何判断烧进AVR芯片里的程序有多大?谢谢~~! 请教如何判断烧进AVR芯片里的程序有多大? H...
chenky Microchip MCU
关于430 RTC 初始化的疑问
RTC在实时时钟模式下时不是应该采用BCD模式吗,但我看到有些实验程序中并没有设置RTCBCD为1...
zzbaizhi 微控制器 MCU
大数码管的显示问题
买了三块大数码管,一块 8 就有成人手掌大小,一共有十支管脚,自己测了一下,找到了阳极、a,b,c,...
XXYIYI 单片机
热门器件
热门资源推荐
器件捷径:
L0 L1 L2 L3 L4 L5 L6 L7 L8 L9 LA LB LC LD LE LF LG LH LI LJ LK LL LM LN LO LP LQ LR LS LT LU LV LW LX LY LZ M0 M1 M2 M3 M4 M5 M6 M7 M8 M9 MA MB MC MD ME MF MG MH MI MJ MK ML MM MN MO MP MQ MR MS MT MU MV MW MX MY MZ N0 N1 N2 N3 N4 N5 N6 N7 N8 NA NB NC ND NE NF NG NH NI NJ NK NL NM NN NO NP NQ NR NS NT NU NV NX NZ O0 O1 O2 O3 OA OB OC OD OE OF OG OH OI OJ OK OL OM ON OP OQ OR OS OT OV OX OY OZ P0 P1 P2 P3 P4 P5 P6 P7 P8 P9 PA PB PC PD PE PF PG PH PI PJ PK PL PM PN PO PP PQ PR PS PT PU PV PW PX PY PZ Q1 Q2 Q3 Q4 Q5 Q6 Q8 Q9 QA QB QC QE QF QG QH QK QL QM QP QR QS QT QV QW QX QY R0 R1 R2 R3 R4 R5 R6 R7 R8 R9 RA RB RC RD RE RF RG RH RI RJ RK RL RM RN RO RP RQ RR RS RT RU RV RW RX RY RZ
需要登录后才可以下载。
登录取消