5KP6.5 ... 5KP110CA
5KP6.5 ... 5KP110CA
Unidirectional and Bidirectional Transient Voltage Suppressor Diodes
Unidirectionale und bidirectional Spannungs-Begrenzer-Dioden
Version 2011-10-28
Peak pulse power dissipation
Maximale Verlustleistung
Ø
8
±0.1
5000 W
6.5...110 V
Ø 8 x 7.5 [mm]
1.5 g
Maximum stand-off voltage
Maximale Sperrspannung
Plastic case
Kunststoffgehäuse
Weight approx.
Gewicht ca.
Plastic material has UL classification 94V-0
Gehäusematerial UL94V-0 klassifiziert
Standard packaging taped in ammo pack
Standard Lieferform gegurtet in Ammo-Pack
62.5
±0.5
Ø
1.2
±0.05
Dimensions - Maße [mm]
For bidirectional types (add suffix “C” or “CA”), electrical characteristics apply in both directions.
Für bidirektionale Dioden (ergänze Suffix “C” oder “CA”) gelten die elektrischen Werte in beiden Richtungen.
Maximum ratings and Characteristics
Peak pulse power dissipation (10/1000 µs waveform)
Impuls-Verlustleistung (Strom-Impuls 10/1000 µs)
Steady state power dissipation
Verlustleistung im Dauerbetrieb
Peak forward surge current, 60 Hz half sine-wave
Stoßstrom für eine 60 Hz Sinus-Halbwelle
Max. instantaneous forward voltage
Augenblickswert der Durchlaßspannung
Junction temperature – Sperrschichttemperatur
Storage temperature – Lagerungstemperatur
Thermal resistance junction to ambient air
Wärmewiderstand Sperrschicht – umgebende Luft
Thermal resistance junction to terminal
Wärmewiderstand Sperrschicht – Anschluss
T
A
= 25°C
T
A
= 50°C
T
A
= 25°C
I
F
= 100A
7,5
Type
±0.1
Grenz- und Kennwerte
P
PPM
P
M(AV)
I
FSM
V
F
T
j
T
S
R
thA
R
thT
5000 W
1
)
8 W
2
)
400 A
3
)
< 3.5 V
3
)
-50...+175°C
-50...+175°C
< 16 K/W
2
)
< 4 K/W
1
2
3
Non-repetitive pulse see curve I
PP
= f (t
r
) / P
PP
= f (t
r
)
Höchstzulässiger Spitzenwert eines einmaligen Impulses, siehe Kurve I
PP
= f (t
r
) / P
PP
= f (t
r
)
Valid, if leads are kept at ambient temperature at a distance of 10 mm from case
Gültig, wenn die Anschlussdrähte in 10 mm Abstand von Gehäuse auf Umgebungstemperatur gehalten werden
Unidirectional diodes only – Nur für unidirektionale Dioden
http://www.diotec.com/
© Diotec Semiconductor AG
1
5KP6.5 ... 5KP110CA
Maximum ratings
Type
Typ
Stand-off voltage
Sperrspannung
V
WM
[V]
5KP6.5
5KP6.5A
5KP7.0
5KP7.0A
5KP7.5
5KP7.5A
5KP8.0
5KP8.0A
5KP8.5
5KP8.5A
5KP9.0
5KP9.0A
5KP10
5KP10A
5KP11
5KP11A
5KP12
5KP12A
5KP13
5KP13A
5KP14
5KP14A
5KP15
5KP15A
5KP16
5KP16A
5KP17
5KP17A
5KP18
5KP18A
5KP20
5KP20A
5KP22
5KP22A
5KP24
5KP24A
5KP26
5KP26A
5KP28
5KP28A
6.5
6.5
7.0
7.0
7.5
7.5
8.0
8.0
8.5
8.5
9.0
9.0
10
10
11
11
12
12
13
13
14
14
15
15
16
16
17
17
18
18
20
20
22
22
24
24
26
26
28
28
Max. rev. current
Max. Sperrstrom
at / bei V
WM
I
D
[µA]
4000
4000
2000
2000
500
500
300
300
100
100
40
40
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
Breakdown voltage at I
T
= 5 mA
Abbruch-Spannung bei I
T
= 5 mA
*) at / bei I
T
= 50 mA
V
BRmin
[V]
7.22 *)
7.22 *)
7.78 *)
7.78 *)
8.33
8.33
8.89
8.89
9.44
9.44
10.0
10.0
11.1
11.1
12.2
12.2
13.3
13.3
14.4
14.4
15.6
15.6
16.7
16.7
17.8
17.8
18.9
18.9
20.0
20.0
22.2
22.2
24.4
24.4
26.7
26.7
28.9
28.9
31.1
31.1
V
BRmax
[V]
9.14 *)
8.30 *)
9.86 *)
8.95 *)
10.67
9.58
11.30
10.23
11.92
10.82
12.7
11.5
14.1
12.8
15.4
14.0
16.9
15.3
18.2
16.5
19.8
17.9
21.1
19.2
22.6
20.5
23.9
21.7
25.3
23.3
28.1
25.5
30.9
28.0
33.8
30.7
36.6
33.2
39.4
35.8
Grenzwerte
Max. clamping voltage
Max. Begrenzer-Spannung
at / bei I
PPM
(10/1000 µs)
V
C
[V]
12.3
11.2
13.3
12.0
14.3
12.9
15.0
13.6
15.6
14.4
16.9
15.4
18.8
17.0
20.1
18.2
22.0
19.9
23.8
21.5
25.8
23.2
26.9
24.4
28.8
26.0
30.5
27.6
32.2
29.2
35.8
32.4
39.4
35.5
43.0
38.9
46.6
42.1
50.0
45.4
I
PPM
[A]
407
446
376
417
350
388
333
368
321
347
296
325
266
294
249
275
227
251
210
233
194
216
186
205
174
192
164
181
155
171
140
154
127
141
116
129
107
119
100
110
2
http://www.diotec.com/
© Diotec Semiconductor AG
5KP6.5 ... 5KP110CA
Maximum ratings
Type
Typ
Stand-off voltage
Sperrspannung
V
WM
[V]
5KP30
5KP30A
5KP33
5KP33A
5KP36
5KP36A
5KP40
5KP40A
5KP43
5KP43A
5KP45
5KP45A
5KP48
5KP48A
5KP51
5KP51A
5KP54
5KP54A
5KP58
5KP58A
5KP60
5KP60A
5KP64
5KP64A
5KP70
5KP70A
5KP75
5KP75A
5KP78
5KP78A
5KP85
5KP85A
5KP90
5KP90A
5KP100
5KP100A
5KP110
5KP110A
30
30
33
33
36
36
40
40
43
43
45
45
48
48
51
51
54
54
58
58
60
60
64
64
70
70
75
75
78
78
85
85
90
90
100
100
110
110
Max. rev. current
Max. Sperrstrom
at / bei V
WM
I
D
[µA]
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
Breakdown voltage at I
T
= 1 mA
Abbruch-Spannung bei I
T
= 1 mA
*) at / bei I
T
= 10 mA
V
BRmin
[V]
33.3
33.3
36.7
36.7
40.0
40.0
44.4
44.4
47.8
47.8
50.0
50.0
53.3
53.3
56.7
56.7
60.0
60.0
64.4
64.4
66.7
66.7
71.1
71.1
77.8
77.8
83.3
83.3
86.7
86.7
94.4
94.4
100
100
111
111
122
122
V
BRmax
[V]
42.2
38.3
46.5
42.2
50.7
46.0
56.3
51.1
60.5
54.9
63.3
57.5
67.5
61.3
71.8
65.2
76.0
69.0
81.6
74.1
84.5
76.7
90.1
81.8
98.6
89.5
105.7
95.8
109.8
99.7
119.2
108.2
126.5
115.5
141.0
128.0
154.5
140.5
Grenzwerte
Max. clamping voltage
Max. Begrenzer-Spannung
at / bei I
PPM
(10/1000 µs)
V
C
[V]
53.5
48.4
59.0
53.3
64.3
58.1
71.4
64.5
76.7
69.4
80.3
72.7
85.5
77.4
91.1
82.4
96.3
87.1
103
93.6
107
96.8
114
103
125
113
134
121
139
126
151
137
160
146
179
162
196
177
I
PPM
[A]
93
103
85
94
78
86
70
78
65
72
62
69
58
65
55
61
52
57
49
53
47
52
44
49
40
44
37
41
36
40
33
36
31
34
28
31
26
28
For bidirectional types (suffix “C” or “CA”), electrical characteristics apply in both directions.
Für bidirektionale Dioden (Suffix “C” oder “CA”) gelten die elektrischen Werte in beiden Richtungen.
© Diotec Semiconductor AG
http://www.diotec.com/
3
5KP6.5 ... 5KP110CA
120
[%]
100
100
[%]
80
80
t
r
= 10 µs
60
60
P
PPM
/2
I
PPM
/2
40
I
PP
20
P
PP
0
0
T
A
50
100
150
[°C]
1
40
I
PP
20
P
PP
0
0
t
P
t
1
2
3
[ms] 4
10/1000µs - pulse waveform
10/1000µs - Impulsform
Peak pulse power/current vs. ambient temperature )
Impuls-Spitzenleistung/Strom vs. Umgebungstemp.
1
)
1
10
3
[kW]
10
2
10
P
PP
1
0.1µs
t
P
1µs
10µs
100µs
1ms
10ms
Non repetitive peak pulse power versus pulse width (10/1000 wave form)
Einzel-Impuls-Spitzenleistung in Abh. von der Pulsdauer (10/1000-Impuls)
1
Valid, if leads are kept at ambient temperature at a distance of 10 mm from case
Gültig, wenn die Anschlussdrähte in 10 mm Abstand von Gehäuse auf Umgebungstemperatur gehalten werden
http://www.diotec.com/
© Diotec Semiconductor AG
4