首页 > 器件类别 > 连接器 > 连接器

62-10325-52-0300

Interconnection Device

器件类别:连接器    连接器   

厂商名称:Gould Fiber Optics

下载文档
器件参数
参数名称
属性值
Reach Compliance Code
unknown
连接器类型
INTERCONNECTION DEVICE
Base Number Matches
1
文档预览
www.gouldfo.com
T hi s i s th e N e w Po w e r of Go u l d
!
1121 Benfield Blvd., Millersville, MD 21108
Toll Free: 800-54-GOULD
VOICE: 410.987.5600 FAX: 410.987.1201
EMAIL: info@gouldfo.com WEB: www.gouldfo.com
Patch Cords
Gould cable assemblies feature quality parts and guaranteed performance specifications.
• Specifications are per mated pair at both 1310nm and 1550nm.
Connector Insertion/Return Loss Specifications for Singlemode Fiber
End Number
Connector
Insertion Loss Typical Return Loss
2=
ST
< 0.50dB
>50dB
3=
FC
< 0.35dB
>50dB
4=
SC
< 0.35dB
>50dB
5=
LC
< 0.35dB
>40dB
6=
FC/APC
< 0.35dB
>60dB
7=
SC/APC
< 0.35dB
>60dB
DATA SHEET- Patch Cords
ORDERING INFORMATION
Product Number
6___- ___ ___ ___ ___ ___ - ___ ___ - ___ ___ ___ ___ 1
Patchcord
Type
2= singlemode
4= multimode
Testing Requirements
0= Insertion Loss testing data only
1= Insertion Loss and Return Loss testing data
2= Insertion Loss and Endface Geometry data
3= Insertion Loss, Return Loss
and Endface Geometry data
Fiber Type
03=Corning SMF-28, 100 Kpsi proof test on fiber
06= Corning Flexcore (5/125)
11= 50/125 Graded Index (Corning)
12= 62.5/125 Graded Index (Corning)
22= 200/230/500, 0.37NA SI MM HCS (Lucent)
23= 200/230/500, 0.48NA SI MM HCS (Lucent)
25= 100/140/250 Step Index (Lucent)
27= Corning Flexcore (7/125)
32= Corning SMF-28, 200 Kpsi proof test on fiber
54= Corning Flexcore (7/125), 200 Kpsi proof test on
fiber
Connector
End A
2= ST/UPC
3= FC/UPC
4= SC/UPC
5= LC/UPC
6= FC/APC
7= SC/APC
A= LC/APC
B= MU/UPC
C= MU/APC
Length in meters xx.xx
i.e.., 3 meters=0300
Connector
End B
0= Pigtail
Assembly
2= ST/UPC
3= FC/UPC
4= SC/UPC
5= LC/UPC
6= FC/APC
7= SC/APC
A= LC/APC
B= MU/UPC
C= MU/APC
Buffer Type
10= No buffering (not recommended!)
11= 900 micron, white, PVDF (Temp. rating –40 to +85
°C,
UL 94V-0 Rated)
12= 900 micron, orange, PVDF (Temp. rating –40 to +85
°C,
UL 94V-0 Rated)
13= 900 micron, blue, PVDF (Temp. rating –40 to +85
°C,
UL 94V-0 Rated)
15= 900 micron, green, PVDF (Temp. rating –40 to +85
°C,
UL 94V-0 Rated)
19= 900 micron, yellow, PVDF (Temp. rating –40 to +85
°C,
UL 94V-0 Rated)
21= 900 micron, white, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
22= 900 micron, orange, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
23= 900 micron, blue, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
24= 900 micron, red, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
25= 900 micron, green, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
26= 900 micron, black, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
27= 900 micron, brown, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
28= 900 micron, gray/slate, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
29= 900 micron, yellow, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
31= 2.9 mm x 0.4mm, Kevlar Reinforced Tubing, yellow
32= 2.9 mm x 0.4 mm, Kevlar Reinforced Tubing, orange
33= 2.9 mm x 0.9 mm, Kevlar Reinforced Tubing, orange
34= 2.9 mm x 0.45 mm, Kevlar Reinforced Tubing, black
01/09/03
www.gouldfo.com
T hi s i s th e N e w Po w e r of Go u l d
!
NOTES:
1. Regarding Multimode cable assemblies, Insertion Loss tested with
broadband light source under fully filled launch conditions. This is the
only launch condition under which Gould Fiber Optics will guarantee
performance for Insertion Loss.
2. For large core (>62.5 micron) fiber, Insertion Loss is the only option for
testing for standard product.
3. Connector options A, B, and C are available for singlemode applications
only as standard practice. For “large core” multimode fiber, only
connector option 2 is available.
4. For large core multimode fiber (fiber codes 22, 23, and 25) the standard
buffering option is 33.
Standard length tolerance is +/- 5 cm on lengths below 20 meters, and +/-
10 cm for lengths above 20 meters. Contact your sales representative for
different options.
Patchcord Part Number Example:
If you want to order a 3.5 meter patchcord with an SC/APC connector on
one end and FC/APC on the other, Corning 200 Kpsi SMF-28 fiber buffered
with 900 micron Black hytrel, and you require IL, RL and endface geometry
data, you would order part number 62-33226-67-03501.
For custom options and additional information, please contact us at:
Phone: 1-410-987-5600
Fax: 1-410-987-1201
Web:
www.gouldfo.com
All data listed in this data sheet is subjected to change without notice. Gould
reserves the right to revise or update the data sheet. Copyright 2002 by
Gould Fiber Optics.
01/09/03
查看更多>
【周周有奖等你拿】您是电路大师还是电路小白?
您是电路大师还是电路小白? 畅玩 CIRCUIT MAKER(电路大师)游戏,您...
eric_wang 电源技术
HAL_SPI_TransmitReceive与osDelay冲突问题
我准备在官方的STM32L476+st253993增加freertos,但是代码下进去系统运行...
m4416202 stm32/stm8
【雅特力AT-START-F435】基于Cute的串口示波器
【雅特力AT-START-F435】基于Cute的串口示波器 为了快速调试和方便的...
zhangbaoyin 国产芯片交流
TI新年活动,大家参加了吗?
主办方:德州仪器半导体技术(上海)有限公司( 德州仪器 )为本次活动的主办方。 活动描述/目的:为推...
dontium 模拟与混合信号
德州仪器:TMS320C6474 DSP 评估板
德州仪器:TMS320C6474 DSP 评估板 ...
德仪DSP新天地 DSP 与 ARM 处理器
螺纹的检测技术
各位大虾,有什么方法可以检测孔内的螺纹?只要检测孔内是否有螺纹就可以了。 螺纹的检测技术 用光照,由...
000juli 嵌入式系统
热门器件
热门资源推荐
器件捷径:
00 01 02 03 04 05 06 07 08 09 0A 0C 0F 0J 0L 0M 0R 0S 0T 0Z 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 1H 1K 1M 1N 1P 1S 1T 1V 1X 1Z 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 2G 2K 2M 2N 2P 2Q 2R 2S 2T 2W 2Z 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F 3G 3H 3J 3K 3L 3M 3N 3P 3R 3S 3T 3V 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4M 4N 4P 4S 4T 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5E 5G 5H 5K 5M 5N 5P 5S 5T 5V 60 61 62 63 64 65 66 67 68 69 6A 6C 6E 6F 6M 6N 6P 6R 6S 6T 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7M 7N 7P 7Q 7V 7W 7X 80 81 82 83 84 85 86 87 88 89 8A 8D 8E 8L 8N 8P 8S 8T 8W 8Y 8Z 90 91 92 93 94 95 96 97 98 99 9A 9B 9C 9D 9F 9G 9H 9L 9S 9T 9W
需要登录后才可以下载。
登录取消