首页 > 器件类别 > 连接器 > 连接器

62-11215-CB-0300

Interconnection Device

器件类别:连接器    连接器   

厂商名称:Gould Fiber Optics

下载文档
器件参数
参数名称
属性值
厂商名称
Gould Fiber Optics
Reach Compliance Code
unknown
连接器类型
INTERCONNECTION DEVICE
Base Number Matches
1
文档预览
www.gouldfo.com
T hi s i s th e N e w Po w e r of Go u l d
!
1121 Benfield Blvd., Millersville, MD 21108
Toll Free: 800-54-GOULD
VOICE: 410.987.5600 FAX: 410.987.1201
EMAIL: info@gouldfo.com WEB: www.gouldfo.com
Patch Cords
Gould cable assemblies feature quality parts and guaranteed performance specifications.
• Specifications are per mated pair at both 1310nm and 1550nm.
Connector Insertion/Return Loss Specifications for Singlemode Fiber
End Number
Connector
Insertion Loss Typical Return Loss
2=
ST
< 0.50dB
>50dB
3=
FC
< 0.35dB
>50dB
4=
SC
< 0.35dB
>50dB
5=
LC
< 0.35dB
>40dB
6=
FC/APC
< 0.35dB
>60dB
7=
SC/APC
< 0.35dB
>60dB
DATA SHEET- Patch Cords
ORDERING INFORMATION
Product Number
6___- ___ ___ ___ ___ ___ - ___ ___ - ___ ___ ___ ___ 1
Patchcord
Type
2= singlemode
4= multimode
Testing Requirements
0= Insertion Loss testing data only
1= Insertion Loss and Return Loss testing data
2= Insertion Loss and Endface Geometry data
3= Insertion Loss, Return Loss
and Endface Geometry data
Fiber Type
03=Corning SMF-28, 100 Kpsi proof test on fiber
06= Corning Flexcore (5/125)
11= 50/125 Graded Index (Corning)
12= 62.5/125 Graded Index (Corning)
22= 200/230/500, 0.37NA SI MM HCS (Lucent)
23= 200/230/500, 0.48NA SI MM HCS (Lucent)
25= 100/140/250 Step Index (Lucent)
27= Corning Flexcore (7/125)
32= Corning SMF-28, 200 Kpsi proof test on fiber
54= Corning Flexcore (7/125), 200 Kpsi proof test on
fiber
Connector
End A
2= ST/UPC
3= FC/UPC
4= SC/UPC
5= LC/UPC
6= FC/APC
7= SC/APC
A= LC/APC
B= MU/UPC
C= MU/APC
Length in meters xx.xx
i.e.., 3 meters=0300
Connector
End B
0= Pigtail
Assembly
2= ST/UPC
3= FC/UPC
4= SC/UPC
5= LC/UPC
6= FC/APC
7= SC/APC
A= LC/APC
B= MU/UPC
C= MU/APC
Buffer Type
10= No buffering (not recommended!)
11= 900 micron, white, PVDF (Temp. rating –40 to +85
°C,
UL 94V-0 Rated)
12= 900 micron, orange, PVDF (Temp. rating –40 to +85
°C,
UL 94V-0 Rated)
13= 900 micron, blue, PVDF (Temp. rating –40 to +85
°C,
UL 94V-0 Rated)
15= 900 micron, green, PVDF (Temp. rating –40 to +85
°C,
UL 94V-0 Rated)
19= 900 micron, yellow, PVDF (Temp. rating –40 to +85
°C,
UL 94V-0 Rated)
21= 900 micron, white, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
22= 900 micron, orange, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
23= 900 micron, blue, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
24= 900 micron, red, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
25= 900 micron, green, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
26= 900 micron, black, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
27= 900 micron, brown, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
28= 900 micron, gray/slate, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
29= 900 micron, yellow, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
31= 2.9 mm x 0.4mm, Kevlar Reinforced Tubing, yellow
32= 2.9 mm x 0.4 mm, Kevlar Reinforced Tubing, orange
33= 2.9 mm x 0.9 mm, Kevlar Reinforced Tubing, orange
34= 2.9 mm x 0.45 mm, Kevlar Reinforced Tubing, black
01/09/03
www.gouldfo.com
T hi s i s th e N e w Po w e r of Go u l d
!
NOTES:
1. Regarding Multimode cable assemblies, Insertion Loss tested with
broadband light source under fully filled launch conditions. This is the
only launch condition under which Gould Fiber Optics will guarantee
performance for Insertion Loss.
2. For large core (>62.5 micron) fiber, Insertion Loss is the only option for
testing for standard product.
3. Connector options A, B, and C are available for singlemode applications
only as standard practice. For “large core” multimode fiber, only
connector option 2 is available.
4. For large core multimode fiber (fiber codes 22, 23, and 25) the standard
buffering option is 33.
Standard length tolerance is +/- 5 cm on lengths below 20 meters, and +/-
10 cm for lengths above 20 meters. Contact your sales representative for
different options.
Patchcord Part Number Example:
If you want to order a 3.5 meter patchcord with an SC/APC connector on
one end and FC/APC on the other, Corning 200 Kpsi SMF-28 fiber buffered
with 900 micron Black hytrel, and you require IL, RL and endface geometry
data, you would order part number 62-33226-67-03501.
For custom options and additional information, please contact us at:
Phone: 1-410-987-5600
Fax: 1-410-987-1201
Web:
www.gouldfo.com
All data listed in this data sheet is subjected to change without notice. Gould
reserves the right to revise or update the data sheet. Copyright 2002 by
Gould Fiber Optics.
01/09/03
查看更多>
KEIL中DEBUG看到正确结果,串口发出的数据就不对了
void main (void) { unsigned char *ptr1; un...
terriot 单片机
为什么在定时器操作中要给TCR赋值两次
问一个简单问题 为什么在定时器操作中要给TCR赋值两次 如 T0TCR=0x03; T0TC...
wangkun2046 嵌入式系统
实时控制技术满足实时工业通信发展的需求 —— 第1部分
在TI Designs参考设计库中讨论了一种设计,以帮助简化符合国际电工委员会(IEC)61158...
fish001 微控制器 MCU
基于F103与X-NUCLEO-IKS01A3的计步手环之唤醒功能
本次计步手环设计基于F103核心板与X-NUCLEO-IKS01A3传感器开发板。唤醒功...
sylar^z ST传感器与低功耗无线技术论坛
MSP430F149设计
我已经很就不用单片机了,最近刚刚发现mp430F149性能不错,看了一些相关的书,考虑做个板子看看,...
lishilong 微控制器 MCU
关于STK的疑问
这段时间要做STK相关的应用,之前没有什么经验,啃完了GSM11.14,还是有些疑问请教论坛的高手!...
hzw9111 嵌入式系统
热门器件
热门资源推荐
器件捷径:
S0 S1 S2 S3 S4 S5 S6 S7 S8 S9 SA SB SC SD SE SF SG SH SI SJ SK SL SM SN SO SP SQ SR SS ST SU SV SW SX SY SZ T0 T1 T2 T3 T4 T5 T6 T7 T8 T9 TA TB TC TD TE TF TG TH TI TJ TK TL TM TN TO TP TQ TR TS TT TU TV TW TX TY TZ U0 U1 U2 U3 U4 U6 U7 U8 UA UB UC UD UE UF UG UH UI UJ UK UL UM UN UP UQ UR US UT UU UV UW UX UZ V0 V1 V2 V3 V4 V5 V6 V7 V8 V9 VA VB VC VD VE VF VG VH VI VJ VK VL VM VN VO VP VQ VR VS VT VU VV VW VX VY VZ W0 W1 W2 W3 W4 W5 W6 W7 W8 W9 WA WB WC WD WE WF WG WH WI WJ WK WL WM WN WO WP WR WS WT WU WV WW WY X0 X1 X2 X3 X4 X5 X7 X8 X9 XA XB XC XD XE XF XG XH XK XL XM XN XO XP XQ XR XS XT XU XV XW XX XY XZ Y0 Y1 Y2 Y4 Y5 Y6 Y9 YA YB YC YD YE YF YG YH YK YL YM YN YP YQ YR YS YT YX Z0 Z1 Z2 Z3 Z4 Z5 Z6 Z8 ZA ZB ZC ZD ZE ZF ZG ZH ZJ ZL ZM ZN ZP ZR ZS ZT ZU ZV ZW ZX ZY
需要登录后才可以下载。
登录取消