首页 > 器件类别 > 连接器 > 连接器

62-31122-76-0300

Interconnection Device

器件类别:连接器    连接器   

厂商名称:Gould Fiber Optics

下载文档
器件参数
参数名称
属性值
Reach Compliance Code
unknown
连接器类型
INTERCONNECTION DEVICE
Base Number Matches
1
文档预览
www.gouldfo.com
T hi s i s th e N e w Po w e r of Go u l d
!
1121 Benfield Blvd., Millersville, MD 21108
Toll Free: 800-54-GOULD
VOICE: 410.987.5600 FAX: 410.987.1201
EMAIL: info@gouldfo.com WEB: www.gouldfo.com
Patch Cords
Gould cable assemblies feature quality parts and guaranteed performance specifications.
• Specifications are per mated pair at both 1310nm and 1550nm.
Connector Insertion/Return Loss Specifications for Singlemode Fiber
End Number
Connector
Insertion Loss Typical Return Loss
2=
ST
< 0.50dB
>50dB
3=
FC
< 0.35dB
>50dB
4=
SC
< 0.35dB
>50dB
5=
LC
< 0.35dB
>40dB
6=
FC/APC
< 0.35dB
>60dB
7=
SC/APC
< 0.35dB
>60dB
DATA SHEET- Patch Cords
ORDERING INFORMATION
Product Number
6___- ___ ___ ___ ___ ___ - ___ ___ - ___ ___ ___ ___ 1
Patchcord
Type
2= singlemode
4= multimode
Testing Requirements
0= Insertion Loss testing data only
1= Insertion Loss and Return Loss testing data
2= Insertion Loss and Endface Geometry data
3= Insertion Loss, Return Loss
and Endface Geometry data
Fiber Type
03=Corning SMF-28, 100 Kpsi proof test on fiber
06= Corning Flexcore (5/125)
11= 50/125 Graded Index (Corning)
12= 62.5/125 Graded Index (Corning)
22= 200/230/500, 0.37NA SI MM HCS (Lucent)
23= 200/230/500, 0.48NA SI MM HCS (Lucent)
25= 100/140/250 Step Index (Lucent)
27= Corning Flexcore (7/125)
32= Corning SMF-28, 200 Kpsi proof test on fiber
54= Corning Flexcore (7/125), 200 Kpsi proof test on
fiber
Connector
End A
2= ST/UPC
3= FC/UPC
4= SC/UPC
5= LC/UPC
6= FC/APC
7= SC/APC
A= LC/APC
B= MU/UPC
C= MU/APC
Length in meters xx.xx
i.e.., 3 meters=0300
Connector
End B
0= Pigtail
Assembly
2= ST/UPC
3= FC/UPC
4= SC/UPC
5= LC/UPC
6= FC/APC
7= SC/APC
A= LC/APC
B= MU/UPC
C= MU/APC
Buffer Type
10= No buffering (not recommended!)
11= 900 micron, white, PVDF (Temp. rating –40 to +85
°C,
UL 94V-0 Rated)
12= 900 micron, orange, PVDF (Temp. rating –40 to +85
°C,
UL 94V-0 Rated)
13= 900 micron, blue, PVDF (Temp. rating –40 to +85
°C,
UL 94V-0 Rated)
15= 900 micron, green, PVDF (Temp. rating –40 to +85
°C,
UL 94V-0 Rated)
19= 900 micron, yellow, PVDF (Temp. rating –40 to +85
°C,
UL 94V-0 Rated)
21= 900 micron, white, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
22= 900 micron, orange, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
23= 900 micron, blue, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
24= 900 micron, red, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
25= 900 micron, green, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
26= 900 micron, black, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
27= 900 micron, brown, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
28= 900 micron, gray/slate, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
29= 900 micron, yellow, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
31= 2.9 mm x 0.4mm, Kevlar Reinforced Tubing, yellow
32= 2.9 mm x 0.4 mm, Kevlar Reinforced Tubing, orange
33= 2.9 mm x 0.9 mm, Kevlar Reinforced Tubing, orange
34= 2.9 mm x 0.45 mm, Kevlar Reinforced Tubing, black
01/09/03
www.gouldfo.com
T hi s i s th e N e w Po w e r of Go u l d
!
NOTES:
1. Regarding Multimode cable assemblies, Insertion Loss tested with
broadband light source under fully filled launch conditions. This is the
only launch condition under which Gould Fiber Optics will guarantee
performance for Insertion Loss.
2. For large core (>62.5 micron) fiber, Insertion Loss is the only option for
testing for standard product.
3. Connector options A, B, and C are available for singlemode applications
only as standard practice. For “large core” multimode fiber, only
connector option 2 is available.
4. For large core multimode fiber (fiber codes 22, 23, and 25) the standard
buffering option is 33.
Standard length tolerance is +/- 5 cm on lengths below 20 meters, and +/-
10 cm for lengths above 20 meters. Contact your sales representative for
different options.
Patchcord Part Number Example:
If you want to order a 3.5 meter patchcord with an SC/APC connector on
one end and FC/APC on the other, Corning 200 Kpsi SMF-28 fiber buffered
with 900 micron Black hytrel, and you require IL, RL and endface geometry
data, you would order part number 62-33226-67-03501.
For custom options and additional information, please contact us at:
Phone: 1-410-987-5600
Fax: 1-410-987-1201
Web:
www.gouldfo.com
All data listed in this data sheet is subjected to change without notice. Gould
reserves the right to revise or update the data sheet. Copyright 2002 by
Gould Fiber Optics.
01/09/03
查看更多>
组建一个DIY团队 有兴趣和时间的可以过来报个名
儿时我们想做什么东西,但有些时候家长不支持,他们不相信我们的能力,他们也不想让自己的孩子把时间放...
cardin6 创意市集
积分电路的输出波形问题
如图是理想积分电路,由于输出和输入的反向关系,在情况(1)中,当输入为恒定直流量时,输出如图中(1...
shaorc 模拟电子
嵌入式系统实验关于大小端转换方法的探讨
摘 要:当前,大多数高校先后开设了嵌入式系统的实验课程。学生在做嵌入式系统的实验时,经常会 遇到字节...
吸铁石上 嵌入式系统
STM8,10位AD的转换速度是多少?
如题,没用过这个IC,想知道一下,哪位知道的说一下 STM8,10...
lishilong stm32/stm8
电源情报站 MPS小程序干货推荐,下载有好礼!4月活动开始啦~
电源情报站 MPS小程序干货推荐,下载有好礼!4月活动开始啦~ 活动时间: 即日起 202...
EEWORLD社区 电源技术
精量的DP86传感器补偿原理图求解,不是很理解
精量的DP86传感器补偿原理图求解,不是很理解 有人吗 ...
qw1525296252 综合技术交流
热门器件
热门资源推荐
器件捷径:
S0 S1 S2 S3 S4 S5 S6 S7 S8 S9 SA SB SC SD SE SF SG SH SI SJ SK SL SM SN SO SP SQ SR SS ST SU SV SW SX SY SZ T0 T1 T2 T3 T4 T5 T6 T7 T8 T9 TA TB TC TD TE TF TG TH TI TJ TK TL TM TN TO TP TQ TR TS TT TU TV TW TX TY TZ U0 U1 U2 U3 U4 U6 U7 U8 UA UB UC UD UE UF UG UH UI UJ UK UL UM UN UP UQ UR US UT UU UV UW UX UZ V0 V1 V2 V3 V4 V5 V6 V7 V8 V9 VA VB VC VD VE VF VG VH VI VJ VK VL VM VN VO VP VQ VR VS VT VU VV VW VX VY VZ W0 W1 W2 W3 W4 W5 W6 W7 W8 W9 WA WB WC WD WE WF WG WH WI WJ WK WL WM WN WO WP WR WS WT WU WV WW WY X0 X1 X2 X3 X4 X5 X7 X8 X9 XA XB XC XD XE XF XG XH XK XL XM XN XO XP XQ XR XS XT XU XV XW XX XY XZ Y0 Y1 Y2 Y4 Y5 Y6 Y9 YA YB YC YD YE YF YG YH YK YL YM YN YP YQ YR YS YT YX Z0 Z1 Z2 Z3 Z4 Z5 Z6 Z8 ZA ZB ZC ZD ZE ZF ZG ZH ZJ ZL ZM ZN ZP ZR ZS ZT ZU ZV ZW ZX ZY
需要登录后才可以下载。
登录取消