首页 > 器件类别 > 连接器 > 连接器

64-30632-5B-0300

Interconnection Device

器件类别:连接器    连接器   

厂商名称:Gould Fiber Optics

下载文档
器件参数
参数名称
属性值
厂商名称
Gould Fiber Optics
Reach Compliance Code
unknown
Is Samacsys
N
连接器类型
INTERCONNECTION DEVICE
Base Number Matches
1
文档预览
www.gouldfo.com
T hi s i s th e N e w Po w e r of Go u l d
!
1121 Benfield Blvd., Millersville, MD 21108
Toll Free: 800-54-GOULD
VOICE: 410.987.5600 FAX: 410.987.1201
EMAIL: info@gouldfo.com WEB: www.gouldfo.com
Patch Cords
Gould cable assemblies feature quality parts and guaranteed performance specifications.
• Specifications are per mated pair at both 1310nm and 1550nm.
Connector Insertion/Return Loss Specifications for Singlemode Fiber
End Number
Connector
Insertion Loss Typical Return Loss
2=
ST
< 0.50dB
>50dB
3=
FC
< 0.35dB
>50dB
4=
SC
< 0.35dB
>50dB
5=
LC
< 0.35dB
>40dB
6=
FC/APC
< 0.35dB
>60dB
7=
SC/APC
< 0.35dB
>60dB
DATA SHEET- Patch Cords
ORDERING INFORMATION
Product Number
6___- ___ ___ ___ ___ ___ - ___ ___ - ___ ___ ___ ___ 1
Patchcord
Type
2= singlemode
4= multimode
Testing Requirements
0= Insertion Loss testing data only
1= Insertion Loss and Return Loss testing data
2= Insertion Loss and Endface Geometry data
3= Insertion Loss, Return Loss
and Endface Geometry data
Fiber Type
03=Corning SMF-28, 100 Kpsi proof test on fiber
06= Corning Flexcore (5/125)
11= 50/125 Graded Index (Corning)
12= 62.5/125 Graded Index (Corning)
22= 200/230/500, 0.37NA SI MM HCS (Lucent)
23= 200/230/500, 0.48NA SI MM HCS (Lucent)
25= 100/140/250 Step Index (Lucent)
27= Corning Flexcore (7/125)
32= Corning SMF-28, 200 Kpsi proof test on fiber
54= Corning Flexcore (7/125), 200 Kpsi proof test on
fiber
Connector
End A
2= ST/UPC
3= FC/UPC
4= SC/UPC
5= LC/UPC
6= FC/APC
7= SC/APC
A= LC/APC
B= MU/UPC
C= MU/APC
Length in meters xx.xx
i.e.., 3 meters=0300
Connector
End B
0= Pigtail
Assembly
2= ST/UPC
3= FC/UPC
4= SC/UPC
5= LC/UPC
6= FC/APC
7= SC/APC
A= LC/APC
B= MU/UPC
C= MU/APC
Buffer Type
10= No buffering (not recommended!)
11= 900 micron, white, PVDF (Temp. rating –40 to +85
°C,
UL 94V-0 Rated)
12= 900 micron, orange, PVDF (Temp. rating –40 to +85
°C,
UL 94V-0 Rated)
13= 900 micron, blue, PVDF (Temp. rating –40 to +85
°C,
UL 94V-0 Rated)
15= 900 micron, green, PVDF (Temp. rating –40 to +85
°C,
UL 94V-0 Rated)
19= 900 micron, yellow, PVDF (Temp. rating –40 to +85
°C,
UL 94V-0 Rated)
21= 900 micron, white, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
22= 900 micron, orange, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
23= 900 micron, blue, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
24= 900 micron, red, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
25= 900 micron, green, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
26= 900 micron, black, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
27= 900 micron, brown, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
28= 900 micron, gray/slate, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
29= 900 micron, yellow, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
31= 2.9 mm x 0.4mm, Kevlar Reinforced Tubing, yellow
32= 2.9 mm x 0.4 mm, Kevlar Reinforced Tubing, orange
33= 2.9 mm x 0.9 mm, Kevlar Reinforced Tubing, orange
34= 2.9 mm x 0.45 mm, Kevlar Reinforced Tubing, black
01/09/03
www.gouldfo.com
T hi s i s th e N e w Po w e r of Go u l d
!
NOTES:
1. Regarding Multimode cable assemblies, Insertion Loss tested with
broadband light source under fully filled launch conditions. This is the
only launch condition under which Gould Fiber Optics will guarantee
performance for Insertion Loss.
2. For large core (>62.5 micron) fiber, Insertion Loss is the only option for
testing for standard product.
3. Connector options A, B, and C are available for singlemode applications
only as standard practice. For “large core” multimode fiber, only
connector option 2 is available.
4. For large core multimode fiber (fiber codes 22, 23, and 25) the standard
buffering option is 33.
Standard length tolerance is +/- 5 cm on lengths below 20 meters, and +/-
10 cm for lengths above 20 meters. Contact your sales representative for
different options.
Patchcord Part Number Example:
If you want to order a 3.5 meter patchcord with an SC/APC connector on
one end and FC/APC on the other, Corning 200 Kpsi SMF-28 fiber buffered
with 900 micron Black hytrel, and you require IL, RL and endface geometry
data, you would order part number 62-33226-67-03501.
For custom options and additional information, please contact us at:
Phone: 1-410-987-5600
Fax: 1-410-987-1201
Web:
www.gouldfo.com
All data listed in this data sheet is subjected to change without notice. Gould
reserves the right to revise or update the data sheet. Copyright 2002 by
Gould Fiber Optics.
01/09/03
查看更多>
《原子Linux驱动开发》3-Linux设备树
学习章节:第4章 Linux设备树 前言: 前面章节中我们多次提到 设备树 这个概念,因为...
2609 Linux与安卓
cypress psoc3
最近要参加一个项目 就是运用这个赛普拉斯公司的 psoc3来进行智能家居的制作,不知道这个好用否? ...
missforever 综合技术交流
NXP LPC1343 开发板 学习之旅(序言)
俗语说的好,“万事开头难”,确实如此啊,从收到LPC1343的开发板到现在,已经有一段时间了...
yujiyuan1984 NXP MCU
stm32的工作环境
想把stm32应用在煤炭井下的装备里,不知道能否适应恶劣的环境要求...
65687831 stm32/stm8
【超小型 Linux 开发套件:Quantum Tiny Linux(带 SoM 和扩展板)】- 1、系统烧录...
# 超小型 Linux 开发套件:Quantum Tiny Linux(带 SoM 和扩展板)...
FFD8 嵌入式系统
新栏目器件口碑专辑上线~呼唤各位老铁前来点评器件!
为了沉淀EE网友们使用器件的经验与智慧,为了给后来者更多有价值的参考,新栏目器件口碑专辑来啦~欢...
EE大学堂 测评中心专版
热门器件
热门资源推荐
器件捷径:
L0 L1 L2 L3 L4 L5 L6 L7 L8 L9 LA LB LC LD LE LF LG LH LI LJ LK LL LM LN LO LP LQ LR LS LT LU LV LW LX LY LZ M0 M1 M2 M3 M4 M5 M6 M7 M8 M9 MA MB MC MD ME MF MG MH MI MJ MK ML MM MN MO MP MQ MR MS MT MU MV MW MX MY MZ N0 N1 N2 N3 N4 N5 N6 N7 N8 NA NB NC ND NE NF NG NH NI NJ NK NL NM NN NO NP NQ NR NS NT NU NV NX NZ O0 O1 O2 O3 OA OB OC OD OE OF OG OH OI OJ OK OL OM ON OP OQ OR OS OT OV OX OY OZ P0 P1 P2 P3 P4 P5 P6 P7 P8 P9 PA PB PC PD PE PF PG PH PI PJ PK PL PM PN PO PP PQ PR PS PT PU PV PW PX PY PZ Q1 Q2 Q3 Q4 Q5 Q6 Q8 Q9 QA QB QC QE QF QG QH QK QL QM QP QR QS QT QV QW QX QY R0 R1 R2 R3 R4 R5 R6 R7 R8 R9 RA RB RC RD RE RF RG RH RI RJ RK RL RM RN RO RP RQ RR RS RT RU RV RW RX RY RZ
需要登录后才可以下载。
登录取消