New Product Bulletin
NP 303
Belden Infinity
®
Cables
These highly flexible control,
power, video and data cables
handle the rigorous speeds and
near-constant motion of C-track
systems, robots, pick-and-place
machines, automatic handling
systems, multi-axis machine
tools, conveyor systems and
wind turbines.
Belden Infinity ‘Continuous-
flexing’ Cables Are Built
Rugged For High Performance
In Any Type of Environment and
Include Enhanced Approvals
With Belden, you can be confident that the cables
you need will be delivered to you when and where
you need them, they will be of consistent high
quality, and our service and support will satisfy
any and all of your requirements.
The Belden Infinity line is indicative of this
promise, consisting of four high performance
cable families built specifically for the rigors of
mission-critical, continuous flexing applications.
The Belden Infinity C-TC+, FCC, Flex Data and Flex
Vision cables help ensure maximum uptime, even
when they must operate in the harshest or most
extreme environments.
To maximize the cables’ flex life and reliability,
Belden combines specialized manufacturing
techniques with precision copper stranding and
rugged insulation and jacketing compounds.
Belden Infinity C-TC+ Cables
for Extreme Flexing
To ensure optimal performance at 10 million flex
cycles, Belden utilizes a unique cable manufacturing
process for its Belden Infinity C-TC+ cables that
nearly eradicates cable memory. The cable’s special
construction also eliminates the performance
concerns associated with conductor torque
and fatigue.
With this rugged, high performance construction,
and the inclusion of oil-, sunlight- and abrasion-
resistant Belflex® jackets, C-TC+ cables meet
the NFPA requirements for industrial machinery.
They are ideal for extreme flexing applications such
as C-track systems, wind turbines, robots, multi-axis
machining, automated assembly systems, material
handling systems, pick-and-place retrieval, automat-
ed storage systems and gantry systems
.
Belden Infinity FCC Cables
For Moderate Flexing
Belden Infinity FCC cables feature oil-, sunlight-
and abrasion-resistant Belflex jackets to meet the
NFPA requirements for industrial machinery. They
are appropriate for C-track and moderate flexing
environments of over 1 million flex cycles, making
them a cost-effective alternative to C-TC+ cables
in applications such as machine tool, assembly lines
and control systems.
Belden Infinity Flex Data Cables
For the effective operation of computer-controlled
equipment or other automation production pro-
cesses, specify Belden Infinity Flex Data cables.
Belden 300V Flex Data twisted pair cables can
withstand 1 million flex cycles with 24 AWG
highly stranded bare copper conductors (41x40)
for exceptional flexibility, overall Beldfoil® + 85%
tinned copper braid shield, foam polyethylene
insulation (with skin) and PVC jacket. The cables
are rated RS-232/485 or RS-232/422 (part no.
7205A) and they have a temperature rating of
-20° to +60°C.
Featured Brand
Belden Infinity Flex Vision Cables
Belden Infinity Flex Vision cables are designed
for use in machine vision applications such as
inspection and measurement devices, automated
warehouse equipment, automated production
processes and motion controlled video.
Belden 75 Ohm Flex Vision coaxial cables can
withstand 1 million flex cycles and are rated UL
AWM Style 1354. They have stranded conductors
for greater flexibility, foam polyethylene insulation,
tinned copper “French Braid” shield for 95% shield
coverage, and a PVC jacket.
Be Certain with Belden
Belden Infinity C-TC+ Cable (10 Million Flex Cycles)
Cable Specifications
Conductors
Insulation
Shielding
Jacket
Jacket Color
Voltage Rating
Fine Stranded Tinned Copper Conductors
PVC/Nylon
Tinned Copper Braid (85% Coverage)
Non-Shielded Version also available
Belflex
Orange
600V UL TC-ER (18 AWG & Larger)
300V UL PLTC-ER (20 AWG)
1000V CSA AWM I/II A/B
1000V WTTC (18 AWG & Larger)
-40°C to +90°C (Cold Impact)
-50°C to +90°C (Cold Bend)
UL TC-ER (18 AWG & Larger)
UL PLTC-ER (20 AWG)
UL MTW & AWM
UL Oil Res I & II
IEEE 1202/383
CSA AWM I/II A/B FT4
Sunlight Resistance
UL Direct Burial
NFPA 79 for Industrial Machinery
Class I & II Div 2 Suitable for Hazardous
Location Installation
C(UL) Type TC & CIC FT4
WTTC
CE & RoHS Compliant
CA Prop 65 Compliant
REACH Compliant
Non-Shielded
Part No.
20 Gauge
7101W
7102W
7105W
7106W
7107W
7108W
7110W
7111W
7113W
7116W
7117W
7122W
7123W
7125W
7126W
7127W
7129W
7145W
No. of
Conductors
3
4
9
12
18
25
3
4
7
18
25
3
4
7
9
12
25
4
85% Braid Shielded
Part No.
No. of
Conductors
7106WS
12
18 Gauge
7111WS
4
Temperature Range
Approvals
16 Gauge
7123WS
4
14 Gauge
12 Gauge
7129WS
7136WS
25
4
•
•
•
•
•
•
•
•
C-TC+
Application Guide
Inspection &
Measurement Equipment
Multi-Axis Machining
Pick & Place Retrieval
Automated
Assembly Systems
Automated Storage
Gantry Systems
Machine Vision
Motion-Controlled
Video
C-Track System
Material
Handling System
Festooning
Robotics
Oil-, Sunlight- &
Abrasion-Resistant
600V UL TC-ER Rated
Servo
Wind Turbines
Power
•
•
•
•
•
Belden Infinity FCC Cable (1 Million Flex Cycles)
Non-Shielded
Part No.
20 Gauge
7400W
7401W
7402W
7403W
7404W
7405W
7406W
7407W
7408W
7409W
7410W
7411W
7412W
7413W
7414W
7415W
7416W
7417W
7418W
7421W
7422W
7423W
7424W
7425W
7426W
7427W
7428W
7429W
7430W
7435W
7436W
7438W
7439W
7440W
7442W
No. of
Conductors
2
3
4
5
7
9
12
18
25
2
3
4
5
7
9
12
18
25
34
2
3
4
5
7
9
12
18
25
34
3
4
7
9
12
25
85% Braid Shielded
Part No.
7401WS
7403WS
7404WS
No. of
Conductors
12 Gauge
3
5
7
10 Gauge
8 Gauge
6 Gauge
Non-Shielded
Part No.
7444W
7445W
7447W
7453W
No. of
Conductors
3
4
4
4
85% Braid Shielded
Part No.
7445WS
7447WS
7450WS
No. of
Conductors
4
4
4
7408WS
7410WS
7411WS
7413WS
7415WS
7416WS
7417WS
25
3
4
7
12
18
25
Cable Specifications
Conductors
Insulation
Shielding
Jacket
Jacket Color
Voltage Rating
Fine Stranded Tinned Copper Conductors
PVC/Nylon
Tinned Copper Braid (85% Coverage)
Non-Shielded Version also available
Belflex
Chrome
600V UL TC-ER (18 AWG & Larger)
300V UL PLTC-ER (20 AWG)
1000V CSA AWM I/II A/B
1000V WTTC (18 AWG & Larger)
-40°C to +90°C (Cold Impact)
-50°C to +90°C (Cold Bend)
UL TC-ER (18 AWG & Larger)
UL PLTC-ER (20 AWG)
UL MTW & AWM
UL Oil Res I & II
IEEE 1202/383
CSA AWM I/II A/B FT4
Sunlight Resistance
UL Direct Burial
NFPA 79 for Industrial Machinery
Class I & II Div 2 Suitable for Hazardous
Location Installation
C(UL) Type TC & CIC FT4
WTTC
CE & RoHS Compliant
CA Prop 65 Compliant
REACH Compliant
18 Gauge
16 Gauge
Temperature Range
7422WS
7423WS
3
4
Approvals
7427WS
7428WS
7429WS
7435WS
7438WS
12
18
25
3
7
14 Gauge
•
•
•
•
•
•
•
FCC
Application Guide
Inspection &
Measurement Equipment
Multi-Axis Machining
Pick & Place Retrieval
Automated
Assembly Systems
Automated Storage
Gantry Systems
Motion-Controlled
Video
Material
Handling System
C-Track System
Machine Vision
Festooning
Robotics
Oil-, Sunlight-
& Abrasion-Resistant
600V UL TC-ER Rated
Servo
Power
Wind Turbines
3
•
•
•
•
•
Be Certain with Belden
Belden Infinity Flex Data Cable (1 Million Flex Cycles)
Part No.
7200A
7201A
7202A
7203A
7205A
7206A
No. of Pairs
1
2
3
4
1
1
RS-Type
232, 485
232, 485
232, 485
232, 485
232, 422
232, 485
Impedance (Ω)
120
120
120
120
100
150
Cable Specifications
Conductors
Insulation
Shielding
Jacket
Jacket Color
Voltage Rating
Temperature Range
Approvals
Fine Stranded Bare Copper Conductors
Foam Polyethylene Insulation with Skin
Overall Beldfoil
®
Shield with Tinned Copper Braid
(85% Coverage)
PVC
Green
300 V RMS
-20°C to +60°C
UL & C(UL) CM Rated
UL Oil Res I & II
RS-232/485
RS-232/422 (Part No. 7205A)
CE & RoHS Compliant
CA Prop 65 Compliant
24 Gauge
•
•
•
•
•
•
•
Flex Data
Application Guide
Inspection &
Measurement Equipment
Pick & Place Retrieval
Multi-Axis Machining
Automated Storage
Automated
Assembly Systems
Material
Handling System
Motion-Controlled
Video
C-Track System
Gantry Systems
Machine Vision
•
•
Oil- & Abrasion-Resistant
UL & C(UL) Rated
Wind Turbines
4
Festooning
Robotics
Power
Servo
Be Certain with Belden
Belden Infinity Cables Offer Better Performance,
Longer Life for Your Applications
1. Reduced Cable
Memory
2. Absence of
Fatigue
3. No Torque
4. No Talc
Non-Belden Cable
Non-Belden Cable
Non-Belden Cable
Non-Belden
Cable
Belden Infinity Cables
help ensure maximum
uptime, even in the
harshest and most
extreme environments.
C-TC+ and FCC Control Cables: Easy Flexing, Longer Flex Life
Unlike conventional cables and cordage, Belden Infinity C-TC+ and FCC cables offer
the following benefits to the end-user:
1. Reduced Cable Memory:
Belden cables are produced in a neutralized
or relaxed state and they remain in this state
throughout their use so they exhibit greater
flex life.
2. Absence of Fatigue:
T
he absence of central core conductors
means easy flexing. Central core conductors
are susceptible to fatigue and failure due to
the intense forces placed on them.
3. No Torque:
Each layer of insulated conductors is cabled
in an opposite direction from the preceding
layer to eliminate torque. The inherent twist
induced in other cable brands causes the
internal conductors to torque and the cable
to corkscrew.
4. No Talc:
An OSHA-compliant, inert slipper compound
reduces friction and facilitates flexing. Cables
that contain airborne contaminants such as talc
can be toxic, irritating, and may contaminate
systems, components or machinery.