760055038 | N-004-DS-8W-FSUYL/D
TeraSPEED® Low Smoke Zero Halogen Riser Distribution Cable, 4 fiber
single-unit, singlemode, yellow
Product Classification
Portfolio
Product Type
Regional Availability
CommScope®
Fiber indoor cable
Asia | Australia/New Zealand | EMEA | Latin America | North America
Standards And Qualifications
EN50575 CPR Cable EuroClass
Cable Qualification Standards
Dca | s1a | d1 | a2
ANSI/ICEA S-83-596 | Telcordia GR-409
Representative Image
General Specifications
Cable Type
Construction Type
Subunit Type
Distribution
Non-armored
Gel-free
Construction Materials
Fiber Type Solution
G.652.D and G.657.A1 , TeraSPEED®
page 1 of 3
March 25, 2019
©2019 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: February 4, 2019
760055038 | N-004-DS-8W-FSUYL/D
Total Fiber Count
Fiber Type
Fiber Type, quantity
Jacket Color
4
G.652.D and G.657.A1, TeraSPEED®
4
Yellow
Dimensions
Cable Weight
Diameter Over Jacket
14.1 lb/kft | 21.0 kg/km
4.65 mm | 0.18 in
Physical Specifications
Minimum Bend Radius, loaded
Minimum Bend Radius, unloaded
7.0 cm | 2.8 in
4.6 cm | 1.8 in
Tensile Load, long term, maximum
45 lbf | 200 N
Tensile Load, short term, maximum
150 lbf | 667 N
Vertical Rise, maximum
500.0 m | 1640.4 ft
Flame Test Specifications
Flame Test Listing
Flame Test Method
NEC OFNR-LS (ETL) and c(ETL)
IEC 60332-3 | IEC 60754-2 | IEC 61034-2 | IEEE 383 | UL 1666 | UL 1685
Environmental Specifications
Environmental Space
Installation Temperature
Operating Temperature
Storage Temperature
Low Smoke Zero Halogen (LSZH) | Riser
-10 °C to +60 °C (+14 °F to +140 °F)
-20 °C to +70 °C (-4 °F to +158 °F)
-40 °C to +70 °C (-40 °F to +158 °F)
Mechanical Test Specifications
Compression
Compression Test Method
Flex
Flex Test Method
Impact
Impact Test Method
Strain
Strain Test Method
Twist
Twist Test Method
page 2 of 3
March 25, 2019
10 N/mm | 57 lb/in
FOTP-41 | IEC 60794-1 E3
100 cycles
FOTP-104 | IEC 60794-1 E6
4.34 ft lb | 5.88 N-m
FOTP-25 | IEC 60794-1 E4
See long and short term tensile loads
FOTP-33 | IEC 60794-1 E1
10 cycles
FOTP-85 | IEC 60794-1 E7
©2019 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: February 4, 2019
760055038 | N-004-DS-8W-FSUYL/D
Environmental Test Specifications
Heat Age
Heat Age Test Method
Low High Bend
Low High Bend Test Method
Temperature Cycle
Temperature Cycle Test Method
-20 °C to +85 °C (-4 °F to +185 °F)
IEC 60794-1 F9
-10 °C to +60 °C (+14 °F to +140 °F)
FOTP-37 | IEC 60794-1 E11
-20 °C to +70 °C (-4 °F to +158 °F)
FOTP-3 | IEC 60794-1 F1
Regulatory Compliance/Certifications
Agency
RoHS 2011/65/EU
ISO 9001:2015
CENELEC
Classification
Compliant
Designed, manufactured and/or distributed under this quality management system
EN 50575 compliant, Declaration of Performance (DoP) available
Included Products
CS -8W-TB (Product Component—not orderable)
—
TeraSPEED ® Singlemode Fiber
CS-8W-
Component—
TeraSPEED®
* Footnotes
Operating Temperature
Specification applicable to non-terminated bulk fiber cable
page 3 of 3
March 25, 2019
©2019 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: February 4, 2019