C O A X I A L
C A B L E S
6.79
Computer and Instrumentation Cable
50 Ohm Ethernet Coax
Description
Part
No.
Standard
Nominal
Conductor
UL NEC/ Standard Lengths Unit Weight
Core OD
(stranding)
C(UL) CEC
Diameter
Type
Ft.
m
Lbs.
kg Nom. DCR Inch mm
Shielding Nominal OD
Materials
Nom. DCR Inch mm
Nominal
Nom. Nom. Capacitance
Vel.
Imp.
of
(Ω) Prop. pF/Ft. pF/m
Nominal
Attenuation
dB/
dB/
MHz 100 Ft. 100m
Thin Ethernet • 20 AWG
Stranded (19x32) .037″ Tinned Copper • Duobond
®
II + 93% Tinned Copper Braid Shield
Foam Polyethylene Insulation • Gray PVC Jacket
UL AWM
Style 1354
(30V 60°C)
9907
NEC:
CM
CL2
CEC:
CM
500
U-1000
1000
1640
U-2500
2500
3280
152.4
U-304.8
304.8
500.0
U-762.0
762.0
1000.0
12.5
25.0
25.0
39.4
60.0
62.5
82.0
5.7
11.4
11.4
17.9
27.3
28.4
37.3
20 AWG .102
(19x32)
.037″
TC
8.8Ω/M′
28.9Ω/km
2.59
Duobond II .185
+ 93%
TC Braid
5.8Ω/M′
19.0Ω/km
4.70
50
80%
25.4
83.3
1
10
50
100
200
400
700
900
1000
1
10
50
100
200
400
700
900
1000
1
10
50
100
200
400
700
900
1000
.4
1.3
2.9
4.2
6.1
8.9
12.1
13.9
14.8
.4
1.3
2.9
4.2
6.1
9.2
12.9
15.0
16.0
.4
1.3
2.9
4.2
6.1
9.2
12.9
15.0
16.0
1.4
4.3
9.5
13.8
20.0
29.2
39.7
45.6
48.6
1.4
4.3
9.5
13.7
20.0
30.2
42.3
49.2
52.5
1.4
4.3
9.5
13.7
20.0
30.2
42.3
49.2
52.5
For Plenum versions of 9907,
see 89907 or 82907.
DEC Part No. 17-01248-00
Plenum • Foam FEP Insulation • Gray Fluorocopolymer Jacket
150°C
89907
NEC:
CMP
CL2P
CEC:
CMP FT6
500
†
1000
2500
†
152.4
304.8
762.0
13.0 5.9
24.0 10.9
60.0 27.3
20 AWG .095
(19x32)
.037″
TC
8.8Ω/M′
28.9Ω/km
2.41
Duobond II .160
+ 93%
TC Braid
5.8Ω/M′
19.0Ω/km
4.06
50
80%
26.0
85.3
RG-58/U Type
DEC Part No. 17-01246-00
Plenum • Foam FEP Insulation • Natural Flamarrest
®
Jacket
75°C
82907
NEC:
500
†
152.4
CMP
U-1000
†
U-304.8
304.8
CL2P
1000
†
762.0
CEC:
2500
†
CMP FT6
12.5 5.7
23.0 10.5
24.0 10.9
57.5 26.1
20 AWG .095
(19x32)
.037″
TC
8.8Ω/M′
28.9Ω/km
2.41
Duobond II .160
+ 93%
TC Braid
5.8Ω/M′
19.0Ω/km
4.06
50
80%
26.0
85.3
RG-58/U Type
Thick Ethernet • 12 AWG
Solid .086″ Bare Copper • Duobond IV* Quad Shield
Foam Polyethylene Insulation • Yellow PVC Jacket
UL AWM
Style 1478
(30V 60°C)
9880
NEC:
CL2
CM
CEC:
CM
500
1000
1640
152.4 66.0 30.0
304.8 131.0 59.5
500.0 219.0 99.9
12 AWG
(solid)
.086″
BC
1.4Ω/M′
4.7Ω/km
.243
6.17
Duobond IV .405
(Duobond II
+ 94% TC Braid
+ Duofoil
®
+ 90% TC
Braid)
1.5Ω/M′
5.0Ω/km
10.29
50
78%
26.0
85.0
1
5
10
50
100
200
400
700
900
1000
1
5
10
50
100
200
400
700
900
1000
.2
.4
.5
1.2
1.7
2.6
3.9
5.5
6.5
6.9
.2
.4
.5
1.2
1.7
2.5
3.8
5.6
6.8
7.2
.6
1.2
1.7
3.9
5.6
8.4
12.8
18.1
21.3
22.6
.6
1.2
1.7
3.8
5.4
8.0
12.5
18.4
22.3
23.6
For Plenum version of 9880,
see 89880.
DEC Part No. 17-00451-00
Ring-band stripes marked every 2.5 meters to aid users in tap placement.
Plenum • Foam FEP Insulation • Orange Fluorocopolymer Jacket
150°C
89880
NEC:
CL2P
CMP
CEC:
CMP FT6
500
†
1000
†
1640
†
152.4 67.0 30.5
304.8 134.0 60.9
500.0 224.7 102.1
12 AWG
(solid)
.086″
BC
1.4Ω/M′
4.7Ω/km
.245
6.22
Duobond IV .375
(Duobond II
+ 90% TC Braid
+ Duofoil
+ 90% TC
Braid)
1.5Ω/M′
5.0Ω/km
9.53
50
78%
26.0
85.0
DEC Part No. 17-00324-00
Ring-band stripes marked every 2.5 meters to aid users in tap placement.
Suitable for Outdoor and Direct Burial applications.
BC = Bare Copper • DCR = DC Resistance • TC = Tinned Copper
Contact the Belden Customer Service Department for a Comprehensive Connector Cross Reference.
1-800-BELDEN-1.
For cable manufactured to latest government revision or other MIL-SPEC requirements, please contact your nearest Belden Regional Sales Office.
*Duobond IV = Duobond II + 94% tinned copper braid + Duofoil + 90% tinned copper braid.
(Plenum version is Duobond II + 90% tinned copper braid + Duofoil + 90% tinned copper braid.)
†
Spools and/or UnReel
®
cartons are one piece, but length may vary ±10% from length shown.
B e l d e n E l e c t r o n i c s D i v i s i o n
Te c h n i c a l S u p p o r t :
1 - 8 0 0 - B E L D E N - 1
o r
1 - 8 0 0 - B E L D E N - 3
•
w w w . b e l d e n . c o m
6
•
Coaxial Cables