DC BLOCKING ATTENUATOR
TNC, 2 GHz, 200 Volts
SPECIFICATIONS:
Models: 8516-XX
Electrical:
Frequency Range
Standard dB Values*
Accuracy of Attenuation:
1 - 6 dB
7 - 20 dB
VSWR:
Impedance:
DC Block Type
Voltage Rating
Input Power
Operating Temp. Range
10 MHz - 2 GHz
0 - 10, 12, 15 & 20 dB
In 1 dB Increments
± 0.3 dB
± 0.5 dB
1.15:1 Max.
50 Ohms
Inner Only
200 Volts
2 Watts Average
-65°C to +125°C
RF in
RF out
Mechanical:
Connectors:
Mates with MIL-STD-348
Passivated Stainless Steel
Gold Plated Beryllium Copper
Schematic Diagram
Conductors:
Model Number:
8516-XX
Male/Female Connectors
Length: 2.38 ±.03 [60.45 ±0.76]
Pictured
Model Number:
8516-XXM
Male/Male Connectors
Length: 2.28 ±.05 [57.91 ±1.27]
Ø.56 [14.22]
Model Number:
8516-XXF
Female/Female Connectors
Length: 2.47 ±.03 [62.74 ±1.27]
2.38 ± .03
[60.45 ± 0.76]
Unit is a unidirectional device. Input shall be at male port unless otherwise specified.
HOW TO ORDER:
Model Number:
8516-XXY
Connector Configuration
= Male/Female
F = Fem/Fem
M = Male/Male
dB Value
Ordering Examples:
Model Number:
8516-20
2 GHz; 20 dB; TNC - Male/Fem
Model Number:
8516-05F
2 GHz; 5 dB; TNC - Fem/Fem
Note: Dimensions in Brackets are Expressed in Millimeters and are for Reference Only.
8516: REV K
Aeroflex / Inmet, Inc.
• 300 Dino Drive, Ann Arbor, MI 48103 • U.S.A.
888-244-6638 or 734-426-5553 • FAX: 734-426-5557
www.aeroflex-inmetcorp.com • sales@aeroflex-inmetcorp.com