Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
9514 Multi-Conductor - 300V Power-Limited Tray Cable
For more Information
please call
1-800-Belden1
General Description:
22 AWG pairs stranded (7x30) tinned copper conductors, twisted pairs, PVC insulation, overall Beldfoil®
shield (100% coverage), PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material Dia. (in.)
4
22
7x30
TC - Tinned Copper .024
Total Number of Conductors:
8
Insulation
Insulation Material:
Insulation Material
Dia. (in.)
F-R PVC - Flame Retardant Polyvinyl Chloride .062
Outer Shield
Outer Shield Material:
Outer Shield Trade Name Type Outer Shield Material
Beldfoil®
Coverage (%)
Tape Aluminum Foil-Polyester Tape 100
Outer Shield Drain Wire AWG:
AWG Stranding Drain Wire Conductor Material
22
7x30
TC - Tinned Copper
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
Nom. Wall Thickness (in.)
F-R PVC - Flame Retardant Polyvinyl Chloride .042
Outer Jacket Ripcord:
Yes
Overall Cable
Overall Nominal Diameter:
0.356 in.
Pair
Pair Color Code Chart:
Number Color
1
2
3
4
Black & Red and Numbered
Black & Red and Numbered
Black & Red and Numbered
Black & Red and Numbered
Mechanical Characteristics (Overall)
Operating Temperature Range:
UL Temperature Rating:
Bulk Cable Weight:
Max. Recommended Pulling Tension:
Min. Bend Radius/Minor Axis:
-30°C To +105°C
105°C
58 lbs/1000 ft.
80 lbs.
3.600 in.
Page 1 of 3
10-30-2013
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
9514 Multi-Conductor - 300V Power-Limited Tray Cable
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification:
CEC/C(UL) Specification:
EU Directive 2011/65/EU (ROHS II):
EU CE Mark:
EU Directive 2000/53/EC (ELV):
EU Directive 2002/95/EC (RoHS):
EU RoHS Compliance Date (mm/dd/yyyy):
EU Directive 2002/96/EC (WEEE):
EU Directive 2003/11/EC (BFR):
CA Prop 65 (CJ for Wire & Cable):
MII Order #39 (China RoHS):
PLTC, ITC, CMG
CMG
Yes
Yes
Yes
Yes
04/01/2005
Yes
Yes
Yes
Yes
Flame Test
UL Flame Test:
C(UL) Flame Test:
IEEE Flame Test:
ICEA Flame Test:
UL1685 FT4 Loading
FT4
1202
T-29-520
Suitability
Suitability - Indoor:
Suitability - Outdoor:
Suitability - Burial:
Sunlight Resistance:
Yes
Yes
Yes
Yes
Plenum/Non-Plenum
Plenum (Y/N):
No
Surface Printing (Overall)
Electrical Characteristics (Overall)
Nom. Inductance:
Inductance (µH/ft)
.21
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/ft)
26
Nom. Capacitance Cond. to Other Conductor & Shield:
Capacitance (pF/ft)
45
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
15
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
15
Max. Operating Voltage - UL:
Voltage
300 V RMS
Page 2 of 3
10-30-2013
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
9514 Multi-Conductor - 300V Power-Limited Tray Cable
Max. Recommended Current:
Current
3.4 Amps per conductor @ 25°C
Put Ups and Colors:
Item #
9514 0601000
9514 0602500
9514 060500
9514 0605000
Putup
1,000 FT
2,500 FT
500 FT
5,000 FT
Ship Weight
67.000 LB
147.500 LB
33.000 LB
315.000 LB
Color
CHROME
CHROME
CHROME
CHROME
Notes
C
Z
C
CZ
Item Desc
4 PR #22 PVC FS PVC
4 PR #22 PVC FS PVC
4 PR #22 PVC FS PVC
4 PR #22 PVC FS PVC
Notes:
C = CRATE REEL PUT-UP.
Z = FINAL PUT-UP LENGTH MAY VARY (+ OR -) 10% FOR SPOOLS OR REELS AND(+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN.
Revision Number: 1
© 2013 Belden, Inc
All Rights Reserved.
Revision Date: 05-14-2007
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 3
10-30-2013