Remote Reset Rocker Switch with Delay OFF Function
• Rocker switch with Delay OFF Function. Switch is kept to turn ON, even
if button is operated to turn OFF, and Switch is turned OFF by external
signal.
• Zero standby power with Reset function, switching OFF by external signal.
• Preventing from application trouble such as a data lost or circuit damage
by forced power OFF.
• Timing control of main power switch turn OFF for safety application
design with Delay OFF function.
• Contact gap of 3 mm minimum.
• UL and cUL standard approved, Conforming to EN standards.
RoHS Compliant
(Please refer the Precautions)
Usage example
Saving energy
by
cutting standby power.
Saving energy
by
preventing forgetting turn OFF main power.
Turning OFF main power
by
remote.
Turning OFF main power of many equipments at the same time.
Timing control of main power switch turn OFF for safety design.
Preventing from circuit and data damage
by
power flicker.
*
There are 2 kinds of main models A8GS. (Delay OFF Function model and Remote Reset model) With regard to the models with Delay OFF Function, please refer to the other catalog.
List of Models
Contact Form
1 to 4: Power contact terminal
a, b: Signal contact terminal
+, -: Coil terminal
Signal Contact Terminal: SPST + Power Contact Terminal: DPST
Signal Contact Terminal
×
1 + Power Contact Terminal
×
2
+
-
1
a
3
2
b
4
Quantity
per box
Terminals
No Marking
Marking on caps
Signal Contact Terminal: CT Connector
Power Contact Terminal: Quick-connect
terminals #187(t=0.8)
A8GS-T1185K
A8GS-T1285K
A8GS-T1385K
Signal Contact Terminal: CT Connector
Power Contact Terminal: Solder termi-
nals
A8GS-T1115K
A8GS-T1215K
A8GS-T1315K
50
Note: 1.
This is not general 3 pole switch.
(1) Signal contact terminal is only for detecting button ON/OFF.
(2) Power contact terminal is for turning ON/OFF of circuit. Switch is turned OFF by external signal only, after turning OFF of button.
1
A8GS-T
Ratings
Contact Ratings
Rated voltage
Power Contact Terminal
125 VAC
250 VAC
Rated current
(Resistive load)
16 A
10 A
Signal Contact Terminal
5 VDC
0.2 A
Note: 1.
The above ratings were tested under the following conditions:
(1) Ambient temperature : 20
±
2
°C
(2) Ambient humidity
: 65
±
5 % RH
(3) Switching frequency : 7 times/min
Reset Coil Ratings
Rated voltage, current
5 VDC 455 mA
Operating voltage
range
4.5 to 5.5 VDC
Rated usage cycle
Coil resistance
(Coil temperature: 20 ± 2
°C)
ON: 50 to 100 ms
11
Ω ±
20 %
OFF: Min 5 sec
Note: 1.
Voltage for coil should be set within operating voltage range and applied time should be within rated usage cycle.
Otherwise the performance of the coil may be deteriorated.
Note: 2.
In case of applying voltage within the range from 5.5 to 24 VDC to the coil, contact your OMRON sales representative.
Contact specifications
Signal contact
Material
Contact
gap
Gold alloy
3 mm
Power contact
Silver alloy
3 mm
Minimum applicable
3 VDC 1 mA
5 VDC 200 mA
load (Reference value) *
* Please refer to '' Using Micro loads'' in ''Precautions'' for more information on the minimum applicable load.
Characteristics
Permissible operating Mechanical
frequency
Electrical
Insulation resistance
Contact resistance
Power contact terminal
Signal contact terminal
Between terminals of the
same polarity
Dielectric strength
Between terminals of the
different polarity
Between each terminals of the
switch and terminals of coil
Between each terminals of
switch and
ground
Vibration resistance *
Shock resistance *
Malfunction
Malfunction
Destruction
Switch operation: 20 times/min max, Coil operation: 7 times/min max
7 times/min max
100 MΩ min (500 VDC)
100 mΩ max (6 VDC to 8 V, 1 A Voltage drop method)
100 mΩ max (6 VDC to 8 V, 0.1 A Voltage drop method)
2,000 VAC 50/60 Hz 1 min
2,000 VAC 50/60 Hz 1 min
4,000 VAC 50/60 Hz 1 min
4,000 VAC 50/60 Hz 1 min
10 to 55 Hz 1.5 mm double amplitude (Malfunction 1 ms max)
300 m/s
2
min (Malfunction 1 ms max)
1000 m/s
2
max
−10
to +55
°C
(with no icing or condensation, 60 % RH max)
90 % RH max (+5 to 35
°C
with no icing or condensation)
Switch operation: 30,000 operations min, Coil operation: 10,000 operations min
Switch operation: 10,000 operations min, Coil operation: 10,000 operations min
100 ms max
Ambient operating temperature
Ambient operating humidity
Durability
Contact release time **
Mechanical
Electrical
Weight
A8GS-TxxxxK: Around 15 g
Note: 1.
Above specification values are initial values.
* For the testing condition in individual specification, contact your OMRON sales representative.
** Time from voltage applied to reset coil to actual contacts opening.
2
A8GS-T
Approved Safety Standards
UL (UL61058-1)
Power contact terminal
Approved safety
standards ratings
16 A 125 VAC
10 A 250 VAC
TUV (EN61058-1)
Power contact terminal
Signal contact terminal
Approved safety
standards ratings
10(4) A 250 VAC
0.2 A 5 VDC
Signal contact terminal
−
Note: 1.
There are no approved models of TV-8 rating for Delay OFF Function models.
Connector for Signal Switch Circuit and Coil Circuit
CT connectors produced by Tyco Electronics Corporation or XR connectors produced by JST shall be used
for connection of Signal and Coil circuit. Other connectors shall not be used.
Tyco Electronics Corporation: CT connecter
Pressure welding type
Connector
Terminal no.
1
Signal
contact terminal
2
3
Coil terminal
1
2
Connection with
Switch
a (Switch COM)
---
b (Switch NO)
+ (Coil)
- (Coil)
179228-2
179228-3
179609-1
179227-1
173977-2
2-179694-2
2XR-6@-P*
173977-3
2-179694-3
3XR-6@-P*
Housing
Contact
AWG #30-26
AWG #26-22
Cramping type
AWG #28-26
AWG #24
JST: XR Connector
AWG #28-26
*
@
indicates Housing color.
3
A8GS-T
Operation
Delay OFF Function
Power contacts are kept in ON status, even if button is operated to turn OFF by manual operation of button.
And Switch is turned OFF by external signal to coil embedded in switch.
(1) Signal contact terminal and Power contact terminal are turned ON by manual operation of button.
(2) Power contact terminal is kept in ON status, even if button is operated to turn OFF by manual operation.
Only Signal contact terminal is turned OFF.
(3) Power contact terminal is turned OFF when external signal is applied to coil.
Furthermore, it is able to turn OFF both signal and power contact terminals from manual ON condition at the same time by
applying voltage to coil as Remote Reset Function.
Delay OFF Function Operation
OFF
Button operating
condition
Power switch terminal
is returned automatically.
(1) Manual ON
(2) Manual
(3) Delay OFF
Signal contact terminal
Power contact terminal
Coil terminal
OFF
OFF
ON
ON
No voltage
applied
OFF
OFF
No voltage
applied
Voltage
applied
Remote Reset Function Operation
OFF
Button operating
condition
(1) Manual
(3) Remote Reset
Button is
returned
automatically.
Signal contact terminal
Power contact terminal
Coil terminal
OFF
OFF
No voltage
applied
ON
ON
OFF
OFF
No voltage
applied
Voltage
applied
Note: 1.
Once switch is turned ON, Power contact terminal is not able to be turned OFF by manual operation.
Please apply the voltage to the coil in order to turn OFF Power switch circuit.
Switch circuit and operating condition
OFF
(1) Manual ON
(2) Manual OFF
(3) Delay OFF / Remote Reset
+
1
a
2
b
4
+
1
a
2
b
4
+
1
a
2
b
4
+
1
a
2
b
4
Load1
-
Load1
-
Load1
-
Load1
-
3
3
3
3
Power
supply 1
Power
supply 1
Power
supply 1
Power
supply 1
Load2
Load2
Load2
Load2
Power
supply 2
Power
supply 2
Power
supply 2
Power
supply 2
*5
VDC applied to coil terminal
4
A8GS-T
Dimensions
(Unit: mm)
/Operating Characteristics
A8GS-T1@ 85K
22
30
2
19.2
16.5
ON
OFF
28. 5
6. 9
1.3
10
27
4.75
0.8
15.8±0.8
18.6
CT Connector
Operating force (OF)
1.8
±
1.4 N
CT Connector
Note:
Note:
Note:
Note:
1.
2.
3.
4.
Unless otherwise specified, a tolerance of
±
0.4 mm applies to all dimensions.
At initial operation or operation after reset, operating force is increased, due to switch structure.
Solder terminals model has different hole shape, comparing with Quick-connect terminals. Outline and characteristics are same.
No models of switch without delay off function (without coil), due to product design.
Panel Cutout
Panel thickness: 0.8 to 2.3 mm
Panel cutout design is for prevention of false insertion.
Please be careful about the direction of the protrusion.
The rollover of the panel shall be on the front face.
And panel back side shall be Edge shape by processing.
4.3
±0.1
1.9
±0.1
27.7
±0.1
R
by
cutting
OFF
26.5
±0.1
19.5
±0.1
ON
(Operating surface direction)
Edge
Note: 1.
Recommendation panel material is "SPCC", however, in case of soft material or Panel back side shape is not edge, mounting
strength may down. Please check and try by actual mounting panel and set the Panel thickness and hole dimension.