1 Watt | DC-DC Converter

厂商名称:Aimtec

厂商官网:http://www.aimtec.ca/

下载文档
文档预览
Click on Series name for product info on aimtec.com
Series AM1G-NZ
1 Watt | DC-DC Converter
FEATURES:
I/O Isolation of 1500 and 3000VDC
Very low no load consumption
Remote On/Off Control
8 pin SIP package
Operating temperature -40 to +100
o
C
Continuous Short circuit protection
Wide 2:1 input range
High efficiency up to 81%
Models
Single output
Model
AM1G-0503S-NZ
AM1G-0505S-NZ
AM1G-0512S-NZ
AM1G-0515S-NZ
AM1G-0524S-NZ
AM1G-1203S-NZ
AM1G-1205S-NZ
AM1G-1209S-NZ
AM1G-1212S-NZ
AM1G-1215S-NZ
AM1G-2403S-NZ
AM1G-2405S-NZ
AM1G-2412S-NZ
AM1G-2415S-NZ
AM1G-2424S-NZ
AM1G-4803S-NZ
AM1G-4805S-NZ
AM1G-4812S-NZ
AM1G-4815S-NZ
AM1G-0503SH30-NZ
AM1G-0505SH30-NZ
AM1G-0512SH30-NZ
AM1G-0515SH30-NZ
AM1G-1203SH30-NZ
AM1G-1205SH30-NZ
AM1G-1209SH30-NZ
AM1G-1212SH30-NZ
AM1G-1215SH30-NZ
AM1G-2403SH30-NZ
AM1G-2405SH30-NZ
AM1G-2412SH30-NZ
AM1G-2415SH30-NZ
AM1G-2424SH30-NZ
AM1G-4803SH30-NZ
AM1G-4805SH30-NZ
AM1G-4812SH30-NZ
AM1G-4815SH30-NZ
Input
Voltage
(V)
4.5-9
4.5-9
4.5-9
4.5-9
4.5-9
9-18
9-18
9-18
9-18
9-18
18-36
18-36
18-36
18-36
18-36
36-75
36-75
36-75
36-75
4.5-9
4.5-9
4.5-9
4.5-9
9-18
9-18
9-18
9-18
9-18
18-36
18-36
18-36
18-36
18-36
36-75
36-75
36-75
36-75
Output
Voltage(V)
3.3
5
12
15
24
3.3
5
9
12
15
3.3
5
12
15
24
3.3
5
12
15
3.3
5
12
15
3.3
5
9
12
15
3.3
5
12
15
24
3.3
5
12
15
Output
Current max
(mA)
303
200
83
67
42
303
200
111
83
67
303
200
83
67
42
303
200
83
67
303
200
83
67
303
200
111
83
67
303
200
83
67
42
303
200
83
67
Isolation
(VDC)
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
Capacitor
Load
(μF)
2700
2200
1000
680
470
2700
2200
1800
1000
680
2700
2200
1000
680
470
2700
2200
1000
680
2700
2200
1000
680
2700
2200
1800
1000
680
2700
2200
1000
680
470
2700
2200
1000
680
Efficiency
(%)
72
72
76
75
74
75
77
79
80
80
75
77
81
79
77
75
76
81
80
72
72
76
75
75
77
79
80
80
75
77
81
79
77
75
76
81
80
www.aimtec.com
F 051e R8
Tel: +1 514 620 2722
1 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM1G-NZ
1 Watt | DC-DC Converter
Models
Dual output
Model
AM1G-0505D-NZ
AM1G-0512D-NZ
AM1G-0515D-NZ
AM1G-1205D-NZ
AM1G-1212D-NZ
AM1G-1215D-NZ
AM1G-2405D-NZ
AM1G-2409D-NZ
AM1G-2412D-NZ
AM1G-2415D-NZ
AM1G-4805D-NZ
AM1G-4812D-NZ
AM1G-4815D-NZ
AM1G-0505DH30-NZ
AM1G-0512DH30-NZ
AM1G-0515DH30-NZ
AM1G-1205DH30-NZ
AM1G-1212DH30-NZ
AM1G-1215DH30-NZ
AM1G-2405DH30-NZ
AM1G-2412DH30-NZ
AM1G-2415DH30-NZ
AM1G-4805DH30-NZ
AM1G-4812DH30-NZ
AM1G-4815DH30-NZ
Input
Voltage (V)
4.5-9
4.5-9
4.5-9
9-18
9-18
9-18
18-36
18-36
18-36
18-36
36-75
36-75
36-75
4.5-9
4.5-9
4.5-9
9-18
9-18
9-18
18-36
18-36
18-36
36-75
36-75
36-75
Output
Voltage(V)
±5
±12
±15
±5
±12
±15
±5
±9
±12
±15
±5
±12
±15
±5
±12
±15
±5
±12
±15
±5
±12
±15
±5
±12
±15
Output
Current max
(mA)
±100
±42
±33
±100
±42
±33
±100
±56
±42
±33
±100
±42
±33
±100
±42
±33
±100
±42
±33
±100
±42
±33
±100
±42
±33
Isolation
(VDC)
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
Capacitor Load
(μF)
±1000
±470
±330
±1000
±470
±330
±1000
±680
±470
±330
±1000
±470
±330
±1000
±470
±330
±1000
±470
±330
±1000
±470
±330
±1000
±470
±330
Efficiency
(%)
73
76
75
78
81
80
80
80
80
80
76
80
80
73
76
75
78
81
80
80
80
80
76
80
80
Input Specifications
Parameters
Voltage range
Peak Input Voltage time
Filter
Maximum Rating
5 Vin
12 Vin
24 Vin
48 Vin
5 Vin
12 Vin
24 Vin
48 Vin
5 Vin
12 Vin
24 Vin
48 Vin
Nominal
5
12
24
48
Typical
4.5-9
9-18
18-36
36-75
Maximum
Units
VDC
1
Capacitor
12
25
50
100
25
12
6
4
30
40
55
70
ON – open or Isolated; OFF – high voltage level (current 5-10mA)
sec
VDC
No load input current
mA
Input Reflected Ripple Current
On/Off Control*
mA
*Note: Exceeding 20mA of control current will permanently damage the converter.
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
www.aimtec.com
F 051e R8
Conditions
60sec, <1mA
3000VDC Isolation,100kHz, 0.1V
1500VDC Isolation,100kHz, 0.1V
Typical
> 1000
30
120
Rated
1500, 3000
Units
VDC
MOhm
pF
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Tel: +1 514 620 2722
2 of 5
Series AM1G-NZ
1 Watt | DC-DC Converter
Output Specifications
Parameters
Voltage accuracy
No Load Voltage accuracy
Voltage balance
Short Circuit Protection
Short Circuit Restart
Line voltage regulation
Load voltage regulation
Temperature coefficient
Transient Recovery Time
Transient Response Deviation
Ripple
Noise
Conditions
5 to 100% load
Dual Output balanced load
Typical
±2
±5
±0.5
Continuous
Automatic restart
±0.5
±0.6
±0.02
2
±5
50
90
Maximum
Units
%
%
LL~HL
load 5~100%
25% load step
25% load step
At 20MHz Bandwidth
At 20MHz Bandwidth
%
%
%/
o
C
msec
%
mV p-p
mV p-p
General Specifications
Parameters
Conditions
Typical
Maximum
Units
Switching frequency
100% load
200
KHz
o
o
Operating temperature
With derating above 85 C
-40 to +100
C
o
Storage temperature
-55 to +125
C
o
C
Case Temperature
105
o
Lead Temperature
1.5mm from case for 10 Seconds
300
C
Cooling
Free air convection
Humidity
95
%
Case material
Plastic (UL94V-0 rated)
Weight
4.9
g
Dimensions
(L x Wx H)
0.87 x 0.37 x 0.47 inch, 22 x 9.5 x 12 mm
MTBF
>1 000 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25
o
C)
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Pin Out Specifications
Pin
1
2
3
5
6
7
8
Dimensions
Dual
22.00
(0.87)
PRINTED
FACE
12.00
(0.47)
9.50
(0.37)
Single
- V Input
+ V Input
On/Off Control
N.C.
+ V Output
- V Output
CS
- V Input
+ V Input
On/Off Control
N.C.
+ V Output
Common
- V Output
12.00
(0.47)
0.50
(0.02)
4.10
(0.16)
2.54
(0.10)
0.50
(0.02)
2.50
(0.98)
1
2
2.10
(0.08)
3
5
6
7
8
0.300
(0.012)
9.50
(0.37)
0.50
(0.02)
www.aimtec.com
F 051e R8
Tel: +1 514 620 2722
3 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM1G-NZ
1 Watt | DC-DC Converter
Derating
Free Air Convection
85º C
100
Output Power (%)
80
Safe Operating Area
60
40
20
0
- 40
- 20
0
20
40
60
80
85
100
105
Ambient Temperature
º C
Recommended EMC Circuit
Model
5 Vin
12 Vin
24 Vin
48 Vin
C1
4.7µF / 50V
4.7µF / 50V
4.7µF / 100V
4.7µF / 100V
C2
4.7µF / 50V
4.7µF / 50V
4.7µF / 50V
4.7µF / 100V
C4
1nF /3KV
1nF /3KV
1nF /3KV
1nF /3KV
LDM
12 µH
12 µH
12 µH
12 µH
MOV
-
-
S14K35
S14K60
TVS
SMCJ13A
SMCJ28A
SMCJ48A
SMCJ90A
C3
680µF /
16V
680µF /
25V
330µF /
50V
330µF /
100V
LDM2
-
-
56µH
56µH
Cd
47nF
/100V
47nF
/100V
47nF
/100V
47nF
/100V
D1
RB160M-
60/1A
RB160M-
60/1A
RB160M-
60/1A
RB160M-
60/1A
Load
R1
See
Formula
See
Formula
See
Formula
See
Formula
Note: Fuse is user selectable
R1 = ((V
cd
– V
d1
– 1.0) / I
cntl
)‐ 300
www.aimtec.com
F 051e R8
Tel: +1 514 620 2722
4 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM1G-NZ
1 Watt | DC-DC Converter
Recommended Circuits
Single Output
+ Vin
C1
LDM
2
C2
CNTL
3
D1 R1
Vin
C3
1
DC
DC
8
Cs
6
Cout
+Vout
7
Vout
Dual Output
+ Vin
C1
LDM
2
C2
CNTL
3
D1 R1
Vin
C3
1
8
Vout
Model
5 Vin
12 Vin
24 Vin
48 Vin
C1
100µF
100µF
10µF
10µF
C2
47µF
47µF
1µF
1µF
LDM
4.7 - 12 µH
4.7 - 12 µH
4.7 - 12 µH
4.7 - 12 µH
C3
47µF / 100V
47µF / 100V
47µF / 100V
47µF / 100V
D1
RB160M-60/1A
RB160M-60/1A
RB160M-60/1A
RB160M-60/1A
R1
See Formula
See Formula
See Formula
See Formula
LDM1
2.2 - 10 µH
2.2 - 10 µH
2.2 – 10 µH
2.2 - 10 µH
CS
10 - 22µF
10 - 22µF
10 - 22µF
10 - 22µF
Cout
100µF
100µF
100µF
100µF
LDM1
6
Cout
+Vout
DC
DC
7
Cout
LDM1
GND
R1 = ((V
cd
– V
d1
– 1.0) / I
cntl
)‐ 300
NOTE: 1.
Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications.
2.
Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured.
3.
Mechanical drawings and specifications are for reference only.
4.
All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified.
5.
Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release.
6.
This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet.
7.
Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R8
Tel: +1 514 620 2722
5 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
查看更多>
热门器件
热门资源推荐
器件捷径:
A0 A1 A2 A3 A4 A5 A6 A7 A8 A9 AA AB AC AD AE AF AG AH AI AJ AK AL AM AN AO AP AQ AR AS AT AU AV AW AX AY AZ B0 B1 B2 B3 B4 B5 B6 B7 B8 B9 BA BB BC BD BE BF BG BH BI BJ BK BL BM BN BO BP BQ BR BS BT BU BV BW BX BY BZ C0 C1 C2 C3 C4 C5 C6 C7 C8 C9 CA CB CC CD CE CF CG CH CI CJ CK CL CM CN CO CP CQ CR CS CT CU CV CW CX CY CZ D0 D1 D2 D3 D4 D5 D6 D7 D8 D9 DA DB DC DD DE DF DG DH DI DJ DK DL DM DN DO DP DQ DR DS DT DU DV DW DX DZ
需要登录后才可以下载。
登录取消