SPECIFICATION CONTROL DRAWING
Title
SCD
ATF+0411
Revision
AUTOMATIC TRANSMISSION CABLE,
RADIATION-CROSSLINKED, MODIFIED FLUOROPOLYMER-INSULATED, 600 VOLT
This specification sheet forms a part of the latest issue of Raychem Specification 63.
Date
1-29-15
D
CONDUCTOR - TIN-COATED COPPER
INSULATION - RADIATION-CROSSLINKED,
MODIFIED FLUOROPOLYMER
TABLE I. CONSTRUCTION DETAILS
CONDUCTOR
STRANDING
(number x
AWG)
7 x 28
19 x 34
19 x 30
19 x 27
CONDUCTOR DIAMETER
(inch)
(mm)
LOWER
SPEC
LIMIT
.037
(.940)
.029
(.737)
.046
(1.17)
.065
(1.65)
UPPER
SPEC
LIMIT
.039
(.991)
.031
(.787)
.049
(1.24)
.069
(1.75)
FINISHED CABLE
MAXIMUM
RESISTANCE
AT 20°C
(ohms/1000 ft.)
(ohms/km)
10.2
(33.5)
16.2
(53.1)
6.23
(20.4)
3.06
(10.0)
DIAMETER
(inch)
(mm)
LOWER
SPEC
LIMIT
.0635
(1.61)
.0555
(1.41)
.0725
(1.84)
.0920
(2.34)
TARGET
VALUE
.0655
(1.66)
.0575
(1.46)
.0745
(1.89)
.0940
(2.39)
UPPER
SPEC
LIMIT
.0675
(1.71)
.0595
(1.51)
.0765
(1.94)
.0960
(2.44)
NOMINAL
WEIGHT
(lbs/1000 ft.)
(kg/km)
5.1
(7.59)
3.7
(5.51)
7.6
(11.3)
13.8
(20.5)
PART NUMBER
1/
WIRE
SIZE
(AWG)
ATFB0411-20-*
ATFC0411-22-*
ATFC0411-18-*
ATFC0411-14-*
20
22
18
14
Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice.
Tyco Electronics Corporation also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer.
1/ COLORS SHALL BE IN ACCORDANCE WITH SAE J1128. COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH SPEC 63.
OTHER CODES AND SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
Dexron, Raychem, TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks.
Page 1 of 2
DIMENSIONS ARE IN INCHES AND, UNLESS OTHERWISE DESIGNATED, ARE NOMINAL.
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
Raychem Wire & Cable
501 Oakside Avenue
Redwood City, CA 94063-3800
Phone: 1-800-227-8816
Fax: 1-650-361-6297
© 2006-2015 Tyco Electronics Corporation. All rights reserved.
Page
Revision
SCD
SPECIFICATION CONTROL DRAWING
2 of 2
D
ATF+0411
TABLE II. PERFORMANCE DETAILS
HEAT RESISTANCE - BEND TESTING
PART NUMBER
1/
ATFB0411-20-*
ATFC0411-22-*
ATFC0411-18-*
ATFC0411-14-*
MANDREL DIAMETER
(inch)
(mm)
(± 3%)
.750
(19.1)
.750
(19.1)
.750
(19.1)
.750
(19.1)
WEIGHT
(lb)
(kg)
(± 3%)
.500
(.227)
.500
(.227)
.500
(.227)
.500
(.227)
DYNAMIC CUT-THROUGH
(lb)
(kg)
(minimum)
INITIAL
TBD
TBD
TBD
TBD
AFTER
IMMERSION
TBD
TBD
TBD
TBD
CABLE RATINGS AND ADDITIONAL REQUIREMENTS
VOLTAGE RATING: 600 volts (dc) at sea level
CONCENTRICITY: 70% (minimum)
CROSSLINK PROOF TEST: Per QC/3/117
FLAMMABILITY: 70 seconds (maximum) afterburn
HEAT RESISTANCE: 150 ± 2°C for 1 hour
no cracking, no dielectric breakdown
INSULATION ELONGATION AND TENSILE STRENGTH:
(Pulled at 2 inches
(51 mm)
per minute)
Elongation, 150% (minimum)
Tensile Strength, 3000 lbf/in
2
(20.7 N/mm
2
)
(minimum)
INSULATION FLAWS:
Impulse Dielectric Test, 6.0 kV (peak)
INSULATION RESISTANCE:
1000 kohms for 1000 ft.
(305 kohms for 1 km)
(minimum)
INSULATION THICKNESS:
0.011 inch
(.279 mm)
(minimum)
0.0126 inch
(.320 mm)
(minimum average)
LOW TEMPERATURE-COLD BEND: -55 ± 3°C for 4 hours
SHRINKAGE: 0.050 inch
(1.27 mm)
(maximum)
STRIP FORCE: 4.5 lbs
(2.04 kg)
(minimum)
THERMAL STABILITY: Short Term, 200 ± 3°C for 168 hours
Elongation Retention, 80% (minimum)
Tensile Strength Retention, 80% (minimum)
TRANSMISSION FLUID RESISTANCE: Dexron VI, 150 ± 2°C for 720 hours
Diameter Swell, 5% (maximum)
Mandrel Wrap, 1x diameter mandrel, no dielectric breakdown
Dynamic Cut-Through, see Table II
VOLTAGE WITHSTAND (Post Environmental):
1000 volts (rms), 60 Hz, 1 minute
1/ PART NUMBER:
The "+" in the part number in the upper right hand corner of pages 1 and 2
shall be replaced with a letter designator to define conductor stranding
(see part numbers in table).
B = 7 Strands C = 19 Strands
The "*" in the part numbers in Tables I and II shall be replaced by a color
code designator.
Example: AWG 20, 7 strands, dark blue: ATFB0411-20-6D
1/ See footer section on page 1
查看更多>
热门器件
热门资源推荐
器件捷径:
00 01 02 03 04 05 06 07 08 09 0A 0C 0F 0J 0L 0M 0R 0S 0T 0Z 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 1H 1K 1M 1N 1P 1S 1T 1V 1X 1Z 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 2G 2K 2M 2N 2P 2Q 2R 2S 2T 2W 2Z 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F 3G 3H 3J 3K 3L 3M 3N 3P 3R 3S 3T 3V 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4M 4N 4P 4S 4T 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5E 5G 5H 5K 5M 5N 5P 5S 5T 5V 60 61 62 63 64 65 66 67 68 69 6A 6C 6E 6F 6M 6N 6P 6R 6S 6T 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7M 7N 7P 7Q 7V 7W 7X 80 81 82 83 84 85 86 87 88 89 8A 8D 8E 8L 8N 8P 8S 8T 8W 8Y 8Z 90 91 92 93 94 95 96 97 98 99 9A 9B 9C 9D 9F 9G 9H 9L 9S 9T 9W