Film Capacitors - Power Factor Correction
Capacitor Contactors
Series/Type:
Ordering code:
Date:
Version:
B44066S****J110/J230
B44066S***J***
February 2018
12
Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the table and then
change the color to "white". This ensures that the table disappears (invisible) for the customer PDF.
Don't change formatting when entering or pasting text in the table and don't add any cell or line in and to it!
Identification/Classification 1
Film Capacitors - Power Factor Correction
(header 1 + top left bar):
Identification/Classification 2
Capacitor Contactors
(header 2 + bottom left header bar):
Ordering code: (top right header bar)
B44066S***J***
Series/Type: (bottom right header bar)
B44066S****J110/J230
Preliminary data (optional):
Department:
CAP FILM ES PFC PM
Date:
February 2018
Version:
12
EPCOS AG 2018. Reproduction, publication and dissemination of this publication, enclosures hereto and the information
contained therein without EPCOS' prior express consent is prohibited.
EPCOS AG is a TDK Group Company.
Film Capacitors - Power Factor Correction
Capacitor Contactors
B44066S***J***
B44066S****J110/J230
Characteristics
Excellent damping of inrush current
Improved power quality (e.g. avoidance of voltage sags)
Longer useful life of main contacts of capacitor contactor
Soft switching of capacitor and thus longer useful life
Enhanced mean life expectancy
Reduced ohmic losses
Easy access for cable connection
AC6b utilization category for switching 3-phase capacitors
Approvals
-
cUL approval
-
CCC (China Compulsory Certification)
B44066S….J230/J110
B44066S9010J230
B44066S1810J230/J110
Features
Resistors
Leading contacts
Pre-contacts
Aux-contacts
Tamper-proof and protected
With wiper function
Snap function
For all types
CAP FILM ES PFC PM
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 2 of 9
February 2018
Film Capacitors - Power Factor Correction
Capacitor Contactors
B44066S***J***
B44066S****J110/J230
Type / Main contacts
Capacitor power at 50 °C
380 ... 400 V
415 ... 440 V
660 ... 690 V
Capacitor power at 60 °C
380 ... 400 V
415 ... 440 V
660 ... 690 V
Coil operating voltage at 50 Hz
1
):
Type ... 230
Type …110
Type …400
Coil operating voltage at 60 Hz
1)
:
Type ... 230
Type ... 110
Type …400
Rated op. current AC6b at 50/60 Hz
50 °C
60 °C
Power loss contactor at max. rated
capacitor current
Rated insulation voltage
Max. frequency of operations:
Contact life:
without reactors
with reactors
Cable cross section for contactors
without thermal overload relay
1 cable per clamp
Main connector
Solid or stranded
Flexible
Flexible with multicore cable end
2 cables per clamp
Solid or stranded
B44066S1810… B44066S2410…
0 ... 12.5
0 ... 13
0 ... 20
0 ... 12.5
0 ... 13
0 ... 20
220 ... 240
110
N/A
230 ... 264
110 ... 120
N/A
0 ... 18
0 ... 18
4.1
690
1)
120
0.25
0.40
10 ... 20
10.5 ... 22
17 ... 33
10 … 20
10.5 ... 22
17 ... 33
220 ... 240
110
N/A
230 ... 264
110 ... 120
N/A
14 ... 28
14 ... 28
5.7
690
1)
120
0.15
0.30
B44066S3210…
10 ... 25
10.5 ... 27
17 ... 41
10 ... 25
10.5 ... 27
17 ... 41
220 ... 240
110
380 … 415
230 ... 264
110 ... 120
400 …440
14 ... 36
14 ...36
7.5
690
1)
120
0.15
0.30
B44066S5010…
20 ... 33.3
23 ... 36
36 ... 55
20 ... 33.3
23 ... 36
36 ... 55
220 ... 240
On request
N/A
230 ... 264
On request
N/A
30 ... 48
30 ... 48
12.6
690
1)
120
0.15
0.30
kvar
kvar
V AC
V AC
A
W
V AC
1/h
Million
opera-
tions
mm
2
mm
2
mm
2
mm
2
0.75 – 6
1–4
0.75 – 4
6+(1-6) /
4+(0.75-4)
2.5+(0.75-2.5) /
1.5+(0.75-1.5)
6+(1.5-6) /
4+(1-4)
2.5+(0.75-2.5) /
1.5+(0.75-1.5)
2
1.5 – 25
2.5 – 16
1.5 – 16
16+(2.5-6) /
10+(4-10)
6+(4-6) /
4+(2.5-4)
16+(2.5-6) /
10+(4-10)
6+(4-6) /
4+(2.5-4)
2
1.5 – 25
2.5 – 16
1.5 – 16
16+(2.5-6) /
10+(4-10)
6+(4-6) /
4+(2.5-4)
16+(2.5-6) /
10+(4-10)
6+(4-6) /
4+(2.5-4)
2
4 – 50
10 – 35
6 – 35
50+4 / 35+6 /
25+(6-16)
16+(6-16) /
10+(6-16)
50+(4-10) /
35+(4-16)
25+(4-25) /
16+(4-16)
2
Flexible
mm
2
Cables per clamp
1) Suitable at 690 V for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): V
imp
= 8 kV.
Data for other conditions on request.
2) Operating range of magnet-coils 0.85 V
s
(min. value of rated control voltage) up to 1.1 • V
s
(max. value of rated control voltage).
CAP FILM ES PFC PM
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 3 of 9
February 2018
Film Capacitors - Power Factor Correction
Capacitor Contactors
B44066S***J***
B44066S****J110/J230
Type/Main contacts
For main connector
Solid AWG
Flexible AWG
Cables per clamp
Solid AWG
B44066S1810… B44066S2410…
18 – 10
18 – 10
2
10+(16-10) /
12+(18-12)
14+(18-14) /
16+(18-16)
10+(14-10) /
12+(18-12)
14+(18-14) /
16+(18-16)
2
0.37
35 / 63
1
690
2)
3/2
10
16 – 10
14 – 4
1
10+(16-10) /
12+(18-12)
14+(18-14) /
16+(18-16)
4+(18-12) /
6+(18-8)
8+(18-8) /
10+(18-12)
2
0.67
50 / 80
1
690
2)
3/2
10
B44066S3210…
16 – 10
14 – 4
1
10+(16-10) /
12+(18-12)
14+(18-14) /
16+(18-16)
4+(18-12) /
6+(18-8)
8+(18-8) /
10+(18-12)
2
0.67
63 / 100
1
690
2)
3/2
10
B44066S5010…
12 – 10
10 – 0
1
10+(12-10) /
12+12
mm
2
Flexible AWG
mm
2
1+(12-10) /
2+(8-12)
3+(12-8) /
4+(10-6)
2
1.03
80 / 160
1
690
2)
3/2
10
Cables per clamp
Weight including auxiliary contact:
Fuses gL (gG) from / to
Auxiliary contacts
Normal Open (NO)
Rated insulation voltage
Rated operational current AC15 at
230 V / 400 V
Rated operational current AC1 at
690 V
1)
kg
A
V AC
A
A
Suitable at 690 V for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): V
imp
= 8 kV.
Data for other conditions on request.
2) Operating range of magnet-coils 0.85 V
s
(min. value of rated control voltage) up to 1.1 • V
s
(max. value of rated control voltage).
CAP FILM ES PFC PM
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 4 of 9
February 2018
Film Capacitors - Power Factor Correction
Capacitor Contactors
B44066S***J***
B44066S****J110/J230
Type/Main contacts
Capacitor power at 50 °C
380 ... 400 V
415 ... 440 V
660 ... 690 V
Capacitor power at 60 °C
380 ... 400 V
415 ... 440 V
660 ... 690 V
Coil operating voltage at 50 Hz1):
Type ... 230
Type …110
Type …400
Coil operating voltage at 60 Hz1):
Type ... 230
Type ... 110
Type …400
Rated op. current AC6b at 50/60 Hz
50 °C
60 °C
Power loss contactor at max. rated
capacitor current
Rated insulation voltage
Max. frequency of operations:
Contact life:
without reactors
with reactors
Cable cross section for contactors
without thermal overload relay; 1 cable
per clamp
Main connector
Solid or stranded
Flexible
Flexible with multicore cable end
2 cables per clamp
Solid or stranded
B44066S6210… B44066S7410…
kvar
20 ... 50
23 ... 53
36 ... 82
20 ... 50
23 ... 53
36 ... 82
220 … 240
110
380 …415
230 … 264
110 … 120
400 … 440
30 … 72
30 … 72
21
690
1)
120
0.15
0.30
20 ... 75
23 ... 75
36 ... 120
20 ... 60
23 ... 64
36 ... 100
220 … 240
110
N/A
230 … 264
110 … 120
N/A
30 … 108
30 … 87
38.7
690
1)
80
0.12
0.20
B44066S9010…
33…80
36…82
57…120
33…75
36…77
57…120
220 … 240
On request
N/A
277
On request
N/A
50 … 115
50 … 108
29
1000
1)
80
0.12
0.20
B44066S9910…
33 ... 100
36 ... 103
57 ... 148
33 ... 90
36 ... 93
57 ... 148
220 … 240
On request
N/A
277
On request
N/A
50 … 144
50 … 130
36
1000
1)
80
0.12
0.20
kvar
V AC
V AC
A
W
V AC
1/h
Million
opera-
tions
mm
2
mm
2
mm
2
mm
2
4 – 50
10 – 35
6 – 35
50+4 / 35+6 /
25+(6-16)
16+(6-16) /
10+(6-16)
50+(4-10) /
35+(4-16)
25+(4-25) /
16+(4-16)
2
12 – 10
10 – 0
1
10+(12-10) /
12+12
1+(12-10) /
2+(8-12)
3+(12-8) /
4+(10-6)
2
4 – 50
10 – 35
6 – 35
50+4 / 35+6 /
25+(6-16) 16+(6-
16) /
10+(6-16)
50+(4-10) /
35+(4-16)
25+(4-25) /
16+(4-16)
2
12 – 10
10 – 0
1
10+(12-10) /
12+12
1+(12-10) /
2+(8-12)
3+(12-8) /
4+(10-6)
2
Top
Below Top
Below
0.5 – 95 +10 120 0.5 – 95 +10 120
Flexible
mm
2
0.5
−
70+10 – 95
0.5
−
70+10 – 95
Cables per clamp
For main connector
Solid AWG
Flexible AWG
Cables per clamp
Solid AWG
Flexible AWG
1+1
1+1
mm
2
mm
2
mm
2
mm
2
Top
18 – 10
18 – 3/0
1+1
Below Top
-- 18 – 10
8 – 4/0 18 – 3/0
1
Below
--
8 – 4/0
+1
Cables per clamp
1)
2)
Suitable at 690 V for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): V
imp
= 8 kV.
Data for other conditions on request.
Operating range of magnet-coils 0.85 V
s
(min. value of rated control voltage) up to 1.1 • V
s
(max. value of rated control voltage).
CAP FILM ES PFC PM
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 5 of 9
February 2018