Chokes and inductors
For high frequency and EMC
RF chokes, HBC series
Series/Type:
B82143A / B82143B
November 2005
7f
fÁRspp
Date:
©
EPCOS AG 2005. Reproduction, publication and dissemination of this publication and the infor-
mation contained therein without EPCOS’ prior express consent is prohibited.
RF chokes
HBC series
HBC choke (High-Current Bobbin Core)
Rated current 850 to 2000 mA
Rated inductance 1 to 27
N
H
Construction
■
Ferrite drum core
■
Winding: enamel copper wire
■
Flame-retardant lacquer coating
B82143A
B82143B
Features
■
Very high rated current
■
Low dc resisctances
■
RoHS-compatible (see page 5)
Applications
■
Decoupling
■
Interference suppression
■
For electronic household appliances,
automotive and entertainment electronics
Terminals
■
Central axial leads, lead-free tinned
■
Radially bent to 5 mm lead spacing
Marking
Inductance indicated by color bands to IEC 60062
Delivery mode
Taped, Ammo and reel packing (see page 7)
Dimensional drawings
B82143A (axial leads, taped)
65±1
53
ø0.8 max.
ø4 max.
B82143B (central radial leads, taped)
9.2 max.
(IEC 60294)
6±0.5
5±0.25 5±0.25
16
3.5 min.
11.5 max.
lacquered/lackiert
5
12.7
IND0126-B
IND0429-B
Minimum lead spacing 12.5 mm
Approx. weight 0.38 g
Please read the
Important notes
at the end of
this document.
Schematic drawing (details page 7)
2
11/05
14
RF chokes
HBC series
Characteristics and ordering codes
For further technical data see page 5.
L
R
μH
1.0
1.2
1.5
1.8
2.2
2.7
3.3
3.9
4.7
5.6
6.8
8.2
10
12
15
18
22
27
Toler-
ance
1)
±
10 %
^
K
Q
min
50
50
50
50
50
50
50
50
50
50
40
40
40
35
35
35
35
35
f
Q
MHz
7.96
7.96
7.96
7.96
7.96
7.96
7.96
7.96
7.96
7.96
7.96
7.96
7.96
2.52
2.52
2.52
2.52
2.52
I
R
mA
2000
1800
1700
1650
1600
1500
1450
1400
1300
1250
1200
1150
1100
1050
1000
950
900
850
R
max
mΩ
80
90
100
110
120
130
140
150
170
190
220
240
250
270
300
330
370
420
f
res, min
MHz
195
180
165
155
140
125
115
105
60
45
35
25
21
17
16
15
13
11
B82143A
B82143B
Ordering code
2)
(reel packing)
3)
B82143+1102K000
B82143+1122K000
B82143+1152K000
B82143+1182K000
B82143+1222K000
B82143+1272K000
B82143+1332K000
B82143+1392K000
B82143+1472K000
B82143+1562K000
B82143+1682K000
B82143+1822K000
B82143+1103K000
B82143+1123K000
B82143+1153K000
B82143+1183K000
B82143+1223K000
B82143+1273K000
1) Closer tolerances upon request.
2) Replace the + by code letter »A« for axial taping or by »B« for radial taping.
3) For Ammo pack the last digit has to be a »9«. Example: B82143A1102K009.
Please read the
Important notes
at the end of
this document.
3
11/05
RF chokes
HBC series
Impedance |Z |
versus frequency f
measured with impedance analyzer
HP 4191A / HP 4194A
10
6
Ω
B82143A/B
|
Z
|
10
5
27 µH
10 µH
1 µH
27 µH
10
1
10 µH
IND0127-N
B82143A
B82143B
Inductance L
versus DC load current I
DC
measured with LCR meter
HP 4275A
10
3
µH
L
10
2
B82143A/B
IND0128-M
10
4
10
3
10
2
10
0
1 µH
10
1
_
1
10
0 6
10
10
7
10
8
Hz 10
f
9
10
10
_
2
10
_
1
10
0
A 10
1
I
DC
Q factor
versus frequency f
measured with impedance analyzer
HP 4194A
100
B82143A/B
Q
IND0129-3
Current derating I
op
/I
R
versus ambient temperature T
A
(rated temperature T
R
= 40
°C)
1.2
IND0552-S-E
I
op
I
R
1.0
0.8
1 µH
10 µH
27 µH
50
0.6
0.4
0.2
0
0
10
4
10
5
10
6
10
7
f
Hz 10
8
0
20
40
60
80
100
˚C 140
T
A
4
11/05
Please read the
Important notes
at the end of
this document.
RF chokes
HBC series
General technical data
Rated inductance L
R
B82143A
B82143B
Measuring frequency: L
≤
10
μH
= 1 MHz
10
μH
< L
≤
4700
μH
= 100 kHz
L > 4700
μH
= 10 kHz
Measuring current:
≤
1 mA
Distance between
measuring clamps:
25.4 mm
Measured with HP 4342A
Maximum permissible DC current
referred to 40
°C
ambient temperature,
for derating see below
≤10%
(referred to initial value) at I
R
at 20
°C
ambient temperature
Measured at 20
°C
ambient temperature,
distance between measuring clamps: 25.4 mm
Measured with Scalar Network Analyzer ZAS
from Rohde & Schwarz
55/125/56 (–55
°C/+125 °C/56
days damp heat test)
to IEC 60068-1
235
°C,
2 s,
≥90%
wetting
to IEC 60068-2–20, test Ta
To IEC 60068-2-20, test Tb 260
°C,
10 s
To IEC 60068-2-21, test Ua
≥20
N
RoHS-compatible is defined as compatible with the follow-
ing documents:
DIRECTIVE 2002/95/EC OF THE EUROPEAN PARLIA-
MENT AND OF THE COUNCIL of 13 February 2003 on the
restriction of the use of certain hazardous substances in
electrical and electronic equipment COM (2004) 606 final
Proposal for a COUNCIL DECISION amending Directive
2002/95/EC of the European Parliament and of the Council
for the purposes of establishing the maximum concentra-
tion values for certain hazardous substances in electrical
and electronic equipment.
When bending the leads, take care that the start-of-winding
areas at the face ends (protected by glue and
lacquer) are not subjected to any mechanical stress.
Q factor Q
min
Rated current I
R
Inductance decrease
ΔL/L
0
DC resistance R
max
Resonance frequency f
res, min
Climatic category
Solderability
Resistance to soldering heat
Tensile strength of leads
RoHS-compatible
Mounting information
Please read the
Important notes
at the end of
this document.
5