Chokes and inductors
For high frequency and EMC
RF chokes, LBC series, radial
Series/Type:
B82144B
November 2005
7f
fÁRspp
Date:
©
EPCOS AG 2005. Reproduction, publication and dissemination of this publication and the infor-
mation contained therein without EPCOS’ prior express consent is prohibited.
RF chokes
LBC series
LBC choke, radial leaded
Rated current 20 to 2500 mA
Rated inductance 1 to 100 000
N
H
Construction
■
Large ferrite drum core
■
Winding: enamel copper wire
■
Flame-retardant lacquer coating
B82144B
Features
■
■
■
■
Very wide inductance range
High rated current
Axial leads on request (B82144F)
RoHS-compatible (see page 5)
Applications
■
RF blocking and filtering
■
Decoupling and interference suppression
■
For telecommunications, automotive electronics,
energy-saving lamps, entertainment electronics
Terminals
■
Radially bent to 5 mm lead spacing, lead-free tinned
Marking
Inductance indicated by color bands in accordance with IEC 60062
Delivery mode
Taped and reeled (packing see page 7)
Dimensional drawing
ø6.5 max.
2 max.
2 max.
1.3 max.
1.3 max.
9.2 max.
(IEC 60294)
0.5 max.
11.5 max.
lacquered/lackiert
_
0.5
18
+1
6 min.
4±0.2
3.8±0.7
12.7±0.3
0.7±0.2
ø0.8 max.
_
0.1
5
+0.6
_
0.5
9
+0.75
16±0.5
IND0447-U
Please read the
Important notes
at the end of
this document.
30.5 max.
2
11/05
RF chokes
LBC series
Characteristics and ordering codes
For further technical data see page 5.
L
R
μH
Toler-
ance
1)
1.0
±
10 %
1.5
^
K
2.2
3.3
4.7
6.8
10
15
22
33
47
68
100
150
220
330
470
680
1000
1500
2200
3300
4700
6800
10000
15000
22000
33000
47000
68000
100000
±
5%
^
J
Q
min
25
25
25
25
25
25
60
60
50
40
40
30
40
40
40
30
30
20
60
60
60
60
60
60
50
50
50
50
40
40
40
f
Q
MHz
7.96
7.96
7.96
7.96
7.96
7.96
2.52
2.52
2.52
2.52
2.52
2.52
0.796
0.796
0.796
0.796
0.796
0.796
0.252
0.252
0.252
0.252
0.252
0.252
0.0796
0.0796
0.0796
0.0796
0.0796
0.0796
0.0796
I
R
mA
2500
2300
2100
1950
1800
1600
1500
1400
1250
1100
900
800
760
670
550
500
400
340
280
230
180
150
120
100
85
50
40
35
30
25
20
R
max
Ω
0.06
0.07
0.09
0.10
0.12
0.15
0.18
0.22
0.28
0.35
0.41
0.52
0.70
0.90
1.30
1.70
2.20
3.10
4.20
6.40
9.50
13.8
21.0
30.0
42.0
75.0
120
150
230
290
440
f
res, min
MHz
200
180
140
120
100
60
24
17
12
8.0
7.0
6.2
5.2
4.5
3.8
3.2
2.9
2.6
2.2
1.9
1.5
1.3
1.1
0.9
0.75
0.50
0.40
0.30
0.26
0.20
0.18
B82144B
Ordering code
B82144B1102K000
B82144B1152K000
B82144B1222K000
B82144B1332K000
B82144B1472K000
B82144B1682K000
B82144B1103K000
B82144B1153K000
B82144B1223K000
B82144B1333J000
B82144B1473J000
B82144B1683J000
B82144B1104J000
B82144B1154J000
B82144B1224J000
B82144B1334J000
B82144B1474J000
B82144B1684J000
B82144B1105J000
B82144B1155J000
B82144B1225J000
B82144B1335J000
B82144B1475J000
B82144B1685J000
B82144B1106J000
B82144B1156J000
B82144B1226J000
B82144B1336J000
B82144B1476J000
B82144B1686J000
B82144B1107J000
1) Closer tolerances upon request.
Please read the
Important notes
at the end of
this document.
3
11/05
RF chokes
LBC series
Impedance |Z |
versus frequency f
measured with impedance analyzer
HP 4191A / HP 4194A
10
7
IND0135-P
B82144B
Inductance L
versus DC load current I
DC
measured with LCR meter
HP 4275A
10
5
µH
L
10
4
10000 µH
IND0136-8
Ω
10000 µH
1000 µH
100 µH
10 µH
B82144B
B82144B
|
Z
| 10
6
10
5
10
4
10
3
10
3
1000 µH
1 µH
10
2
100 µH
10
1
10 µH
10
2
10
1
10
0
5
10
10
0
_
1
1 µH
10
6
10
7
10
8
f
Hz 10
9
10
10
_
2
10
_
1
10
0
A
10
1
I
DC
Current derating I
op
/I
R
versus ambient temperature T
A
(rated temperature T
R
= 40
°C)
Q factor
versus frequency f
measured with impedance analyzer
HP 4194A
200
B82144B
Q
IND0137-9
1.2
IND0552-S-E
I
op
I
R
1.0
0.8
10000 µH
1000 µH
100 µH
10 µH
1 µH
100
0.6
0.4
0.2
0
4
10
10
5
10
6
10
7
f
Hz 10
8
0
0
20
40
60
80
100
˚C 140
T
A
4
11/05
Please read the
Important notes
at the end of
this document.
RF chokes
LBC series
General technical data
Rated inductance L
R
B82144B
Measuring frequency: L
≤
10
μH
= 1 MHz
10
μH
< L
≤
4700
μH
= 100 kHz
L > 4700
μH
= 10 kHz
Measuring current:
≤
1 mA
Distance between
measuring clamps:
25.4 mm
Measured with HP 4342A
Maximum permissible DC current
referred to 40
°C
ambient temperature,
for derating see below
≤10%
(referred to initial value) at I
R
at 20
°C
ambient temperature
Measured at 20
°C
ambient temperature,
distance between measuring clamps: 25.4 mm
Measured with Scalar Network Analyzer ZAS
from Rohde & Schwarz
55/125/56 (–55
°C/+125 °C/56
days damp heat test)
to IEC 60068-1
235
°C,
2 s,
≥90%
wetting
to IEC 60068-2–20, test Ta
To IEC 60068-2-20, test Tb 260
°C,
10 s
To IEC 60068-2-21, test Ua
≥20
N
RoHS-compatible is defined as compatible with the follow-
ing documents:
DIRECTIVE 2002/95/EC OF THE EUROPEAN PARLIA-
MENT AND OF THE COUNCIL of 13 February 2003 on the
restriction of the use of certain hazardous substances in
electrical and electronic equipment COM (2004) 606 final
Proposal for a COUNCIL DECISION amending Directive
2002/95/EC of the European Parliament and of the Council
for the purposes of establishing the maximum concentra-
tion values for certain hazardous substances in electrical
and electronic equipment.
When bending the leads, take care that the start-of-winding
areas at the face ends (protected by glue and
lacquer) are not subjected to any mechanical stress.
Q factor Q
min
Rated current I
R
Inductance decrease
ΔL/L
0
DC resistance R
max
Resonance frequency f
res, min
Climatic category
Solderability
Resistance to soldering heat
Tensile strength of leads
RoHS-compatible
Mounting information
Please read the
Important notes
at the end of
this document.
5