BAT42
SILICON PLANAR SCHOTTKY DIODES
FEATURES
* Fast Switching Device(T
RR
<4.0nS)
* DO-35 Package (JEDEC)
* Through-Hole Device Type Mounting
* Hermetically Sealed Glass
* Compression Bonded Construction
* All external surfaces are corrosion resistant and leads
are readily solderable
.022 (0.56)
DIA.
.018 (0.46)
1.02 (26.0)
MIN.
DO-35
.165 (4.2)
MAX.
.079 (2.0)
MAX.
1.02 (26.0)
MIN.
DIA.
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25
o
C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
Dimensions in inches and (millimeters)
MAXIMUM RATINGES
( @ T
A
= 25
o
C unless otherwise noted )
RATINGS
Maximum Forward Comtinuous Reverse Voltage
Maximum Forward Comtinuous Current @ T A =25
O
C
Maximum Peak Forward Current @tp<1s,d<0.5
Surge Forward Current @ tp<10ms
Maximum Power Dissipation @ T A =65 C
O
SYMBOL
V
R
I
F
I
FRM
I
FSM
P
D
T
J
T
STG
o
BAT42
30
200
500
4
200
125
-65 to + 150
UNITS
V
mAmps
mAmps
Amps
mW
O
Junction Temperature
Storage Temperature Range
C
C
O
ELECTRICAL CHARACTERISTICS
( @ T
A
= 25 C unless otherwise noted )
CHARACTERISTICS
Reverse breakdown voltage (I
R
=100mA)
Reverse voltage leakage current (V
R
=25V,T
J
=25 C)
O
(V
R
=25V,T
J
=100 C)
O
SYMBOL
V
(BR)R
I
R
MIN.
30
-
TYP.
-
-
-
-
MAX.
-
0.5
100
0.40
0.65
1.0
-
5
UNITS
V
mA
(I
F
=10mA)
Forward voltage Pulse Tesx tp<300ms,d<2% (I
F
=50mA)
(I
F
=200mA)
Diode capacitance (V
R
=1,f=1MHz)
Reveres recovery time (I
F
=I
R
=10mA,I
RR
=1mA,R
L
=100W)
C
D
-
-
V
F
-
-
-
7.0
-
V
pF
nS
2006-3
t
rr
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liabi-
lity for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" paramet-
ers which may be included on RECTRON data sheets and/ or specifications ca-
n and do vary in different applications and actual performance may vary over ti-
me. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other rela-
ted applications where a failure or malfunction of component or circuitry may di-
rectly or indirectly cause injury or threaten a life without expressed written appr-
oval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rect-
ron Inc and its subsidiaries harmless against all claims, damages and expendit-
ures.
RECTRON