Modbus Flexibility – Serial & Ethernet, Masters & Slaves
0 ~ 4A
0 ~ 2A
View Messaging Status in Real Time
96W
96W
Ultra Compact IP30 Metal Enclosure
150mVp-p
200mVp-p
International Power Supply (included
24 ~ 30V
24V
48 ~ 56V
±1.0%
±1.0%
±1.0%
3000ms, 50ms/115VAC at full load
SERIAL
PORT
DB9 Male
Removable
Terminal Block
±1.0%
±1.0%
±1.0%
Models MESP211D and MESP211T, Vlinx series Modbus Gateways, connect
HOLD UP TIME (Typ.)
50ms/230VAC
20ms/115VAC at full load
INFORMATION
ORDERING
Modbus devices to Ethernet networks and let you monitor
~
and control Modbus
370VDC
VOLTAGE RANGE
Note.6
85 264VAC
120 ~
MODEL NUMBER PROTOCOL
devices from anywhere on the Ethernet LAN or WAN.
47 ~ 63Hz
up to 16
Supporting
FREQUENCY RANGE
MESP211D
RS-232/422/485
masters and 32 slaves, these gateways
(Typ.)
an auto-detecting 10/100
POWER FACTOR
feature
PF
≧
0.95/230VAC
PF
≧
0.98/115VAC at full load
MESP211T
RS-232/422/485
Ethernet
INPUT
RJ-45 port and a serial port that supports RS-232/422/485
copper
EFFICIENCY (Typ.)
83%
86%
communications via a DB9 male or a terminal block connection.
1.3A/115VAC
0.8A/230VAC
COLD START 30A/115VAC
60A/230VAC
The product is built for use in industrial environments with a heavy-duty metal
ACCESSORIES
<1mA / 240VAC
LEAKAGE CURRENT
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
ETHERNET ETHERNET
PORT
CONNECTOR
1
RJ45
1
87%
RJ45
enclosure that is panel (standard) or DIN rail mountable (with optional adapters).
SMI6-12-V-P5 -
Included Power Supply, 12 VDC 6 Watt, 5MM Plug, International AC Input,
105 ~ 150%
10 to 30
The product can be supplied with a DC power source ranging from
rated output power
International AC Blades
OVERLOAD
Protection
recovers automatically after fault
VDC and features a barrel connector. A power supply is included.
type :
Constant current limiting,
Optional DIN rail adapter clip (pair)
condition is removed
DRAD35
-
PROTECTION
Protection type : Shut down o/p voltage, re-power on to recover
Ease of Use
Shut
are simple, easy
Configuration, upgrades and
TEMPERATURE
serial server
down o/p voltage, auto-recovery or re-power on to recover
OVER
monitoring of the
tasks with Vlinx Manager
OK SIGNAL
installs on your PC giving access to
Software. It
FUNCTION DC
Relay contact rating(max.): 30V/1A resistive
the serial server via your desktop. Remotely manage the Modbus Gateway
"Derating Curve")
-10 ~ +60
℃
(Refer to
WORKING TEMP.
over a LAN or WAN via the build-in web server. This is
20 ~ 90% RH non-condensing
helpful for off-site
WORKING HUMIDITY
troubleshooting and can be done
TEMP., HUMIDITY
-40 ~ +85
℃
, 10 ~ 95% RH
with an ordinary web browser.
ENVIRONMENT STORAGE
TEMP. COEFFICIENT
±
0.03%/
℃
(0 ~ 50
℃
)
OVER VOLTAGE
15.6 ~ 18V
232NM9
- Optional mull modem crossover cable
31.2 ~ 36V
57.6 ~ 64.8V
Software Support
Component : 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ; Mounting : Compliance to IEC60068-2-6
VIBRATION
Windows XP (32/64 bit), 2003 Server (32/64 bit), Vista 32/64 bit), 2008 Server
UL508, TUV EN60950-1 approved
SAFETY STANDARDS
(32/64 bit), Windows 7 (32/64 bit), Windows 8 (32/64 bit), Windows 10 (32/64
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
SAFETY & WITHSTAND VOLTAGE
bit).
EMC
ISOLATION RESISTANCE
(Note 4)
EMC EMISSION
EMC IMMUNITY
MTBF
DIMENSION
PACKING
I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25
℃
/ 70% RH
Compliance to EN55011, EN55032 (CISPR32), EN61204-3 Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A
346K hrs min. MIL-HDBK-217F (25
℃
)
55*90*100mm (W*H*D)
0.42Kg; 30pcs/13.6Kg/0.82CUFT
OTHERS
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25
℃
of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
6. Deating maybe needed under low input voltages, please check the derating curve for more detail.
All product specifications are subject to change without notice.
File Name:MDR-100-SPEC 2017-07-07
MESP211D & MESP211T_3617ds
orders@advantech-bb.com
support@advantech-bb.com
Corporate Headquarters: 707 Dayton Road, PO Box 1040 Ottawa, IL 61350 USA 815-433-5100 Fax 433-5104
European Office: Westlink Commercial Park, Oranmore Co. Galway Ireland +353 91 792444 Fax +353 91 792445
96W Single Output Industrial DIN Rail Power Supply